The TH6700 series is a single output, wide-range programmable switching DC power supply available in 360W, 720W and 1080W outputs. Users can realize master-slave series connection of 2 units or master-slave parallel connection of 3 units of TH6700 power supply to meet higher output voltage and output current requirements.
The TH6700 series has an adjustable slope function, which allows the user to set the rise and fall time of the output voltage and current to avoid damaging the device by the surge current during the switching moment.
The constant voltage/constant current prioritization mode of TH6700 series can well protect the measured parts. Conventional power supplies are usually in CV mode when the output is turned on, which will instantly bring large inrush current to capacitive loads. TH6700 series can be prioritized to run in CC mode when the output is turned on, avoiding the sudden spike current and protecting the device.
The programmable internal resistance function of the TH6700 series can be applied to simulate the output of a battery. For example, the TH6700 can set the resistor value that simulates the internal resistance of the battery so that the output voltage drops.
The TH6700 series provides OVP, OCP and OTP protection. Once the output voltage or current exceeds the pre-set value, the output will shut down immediately; once the temperature inside the machine exceeds a certain temperature, the output will also shut down immediately.
The rear panel of TH6700 series can be connected to two-end measurement or four-end measurement. When connected as a four-terminal measurement, it has a remote compensation function, which can compensate for the voltage drop from the power supply to the device to be measured.
Functional Features
A. Adjustable slope function
Control the output by setting the voltage or current rise/fall time to obtain the voltage/current conversion rate
For example, if you set the output voltage to 20V and the voltage conversion rate to 5V/s, the rise time is 4s;
A voltage conversion rate of 10V/s results in a rise time of 2s;
A voltage conversion rate of 20V/s results in a rise time of 1s;
A voltage conversion rate of 40V/s results in a rise time of 0.5s.

B. Programmable Internal Resistors - Emulates Battery Outputs
Batteries generally have internal resistors, and when powered by batteries, the output voltage drops due to voltage dividing by the battery's internal resistors.
Calculation formula:



Use the TH6700 to set the analog internal resistance value so that the output voltage falls, simulating the true output of the battery.
C. Data Retention - Recording of DUT operational data
Used to record data such as current, voltage, time, etc., start recording at a rate of 1 time/s after turning on the recording, maximum 5000 times.
Connect the sense terminal to record the actual voltage and current values at both ends of the measured part;
Without connecting the sense terminal the voltage and current values of the TH6700 output are recorded.
When finished, the instrument data will be saved with a CSV extension to the CSV folder on the USB flash drive.

D. Constant Voltage (CV)/Constant Current (CC) Priority Selection Mode - Protects DUTs
Conventional power supplies are usually in CV mode when the output is turned on, which can instantly introduce a large inrush current to capacitive loads.
Constant Voltage Priority Mode for obtaining a faster rate of voltage creep when the output is turned on in order to target test scenarios that require high voltage speeds.
Constant Current Priority Mode means that at the moment the output is turned on, it operates preferentially in CC mode and can.
1. Avoids sudden spikes in current and protects the device from damage by inrush current.
2. Output current without overshoot, used to test the constant current operating characteristics of the object to be tested



| parameters | TH6711 | TH6712 | TH6713 | TH6721 | TH6722 | TH6723 | ||
| exports | power (output) | rating | 360W | 720W | 1080W | 360W | 720W | 1080W |
| power limit | Approximate power rating*105% | |||||||
| input voltage | rated voltage | 0-30V | 0-30V | 0-30V | 0-80V | 0-80V | 0-80V | |
| Maximum voltage | 31.5V | 84V | ||||||
| amps | rated current | 0-33A | 0-66A | 0-100A | 0-12.5A | 0-25A | 0-37.5A | |
| Maximum current | 36A | 72A | 108A | 13.5A | 27A | 40.5A | ||
| found
install |
input voltage | realm | 0-31.5V | 0~84V | ||||
| amps | realm | 0~36A | 0-72A | 0-108A | 0-13.5A | 0-27A | 0-40.5A | |
| Load regulation rate | input voltage | ≤20mV | ≤45mV | |||||
| amps | ≤41mA | ≤77mA | ≤113mA | ≤18.5mA | ≤32mA | ≤45.5mA | ||
| Power conditioning ratio | input voltage | ≤18mV | ≤43mV | |||||
| amps | ≤41mA | ≤77mA | ≤113mA | ≤18.5mA | ≤32mA | ≤45.5mA | ||
| Setting value resolution | input voltage | 10mV | ||||||
| amps | 10mA | 10mA | 100mA | 10mA | 10mA | 10mA | ||
| Readback resolution | input voltage | 10mV | ||||||
| amps | 10mA | 10mA | 100mA | 10mA | 10mA | 10mA | ||
| Setpoint accuracy
(25°C±5°C) |
Voltage (>0.1V) | ≤0.1%+10mV | ||||||
| Current (>0.1A) | ≤0.1%+30mA | ≤0.1%+60mA | ≤0.1%+100mA | ≤0.1%+20mA | ≤0.1%+40mA | ≤0.1%+50mA | ||
| Readback accuracy
(25°C±5°C) |
Voltage (>0.1V) | ≤0.1%+20mV | ||||||
| Current (>0.1A) | ≤0.1%+40mA | ≤0.1%+70mA | ≤0.1%+100mA | ≤0.1%+20mA | ≤0.1%+40mA | ≤0.1%+50mA | ||
| Ripple and Noise
(20Hz-2MHz) |
differential mode voltage | ≤60mVp-p and 7mVrms | ≤80mVp-p and 11mVrms | ≤100mVp-p and 14mVrms | ≤60mVp-p and
7mVrms |
≤80mVp-p and
11mVrms |
≤100mVp-p and 14mVrms | |
| Differential mode current | ≤72mArms | ≤144mArms | ≤216mArms | ≤27mArms | ≤54mArms | ≤81mArms | ||
| Dynamic recovery time
(50%-100% loads) Frequency = 100 Hz |
Recovery to 0.1% + 10mV: ≤2ms | |||||||
| Rise time (no load) | 10%-90% | ≤50ms | ||||||
| Rise time (full load) | 10%-90% | ≤50ms | ||||||
| Descent time (full load) | 90%-10% | ≤50ms | ||||||
| Descent time (no load) | 90%-10% | ≤500ms | ||||||
| timers | Setting range | 0-9999999 (hours, minutes and seconds) | ||||||
| start-up delay | Setting range | 0-99.99s | ||||||
| stop delay | Setting range | 0-99.99s | ||||||
| Slope Setting | Voltage rise | 0.01-60V/s | 0.1-160V/s | |||||
| voltage drop | 0.01-60V/s | 0.1-160V/s | ||||||
| Current Rise | 0.01-72A/s | 0.1-144A/s | 0.1-216A/s | 0.01-27A/s | 0.01-54A/s | 0.01-81A/s | ||
| Current drop | 0.01-72A/s | 0.1-144A/s | 0.1-216A/s | 0.01-27A/s | 0.01-54A/s | 0.01-81A/s | ||
| analog internal resistance | Setting range | 0-0.833Ω | 0-0.417Ω | 0-0.278Ω | 0-5.926Ω | 0-2.963Ω | 0-1.975Ω | |
| External Voltage Control
(25°C±5°C) |
CV accuracy | Rated output voltage ±0.5% | ||||||
| CC Accuracy | Rated output current ±1% | |||||||
| External Resistance Control
(25°C±5°C) |
CV Accuracy | Rated output voltage ±1.5% | ||||||
| CC Accuracy | Rated output current ±1.5% | |||||||
| power factor | 100VAC (full load) | 0.99 | ||||||
| 200VAC (full load) | 0.97 | |||||||
| efficiencies | 100VAC (full load) | 75% | 76% | |||||
| 200VAC (full load) | 77% | 78% | ||||||
| master-slave control | master-slave parallel connection | Includes up to 3 mainframes in parallel | ||||||
| master-slave tandem | Includes up to 2 mainframes in series | |||||||
| safeguard | Overvoltage OVP | 3-33V | 3-33V | 3-33V | 8-88V | 8-88V | 8-88V | |
| Overcurrent OCP | 3.6-37.8A | 5-75.6A | 5-113.4A | 1.35-14.18A | 2.7-28.35A | 4.05-42.53A | ||
| Over Temperature OTP | Internal Temperature Rise Decision | |||||||
| Volume and weight | Outline volume (mm) | 215(W)×146(H)×420(D) | ||||||
| Upper shelf volume (mm) | 215(W)×132(H)×420(D) | |||||||
| Weight (net) | 3kg | 5.3kg | 7.5kg | 3kg | 5.3kg | 7.5kg | ||
| Power supply | 88-265VAC, 50/60HZ | |||||||
| Notes:
l Power conditioning rate (88-132VAC or 170-265VAC, constant load) l Load regulation ratio (no load - full load, constant input voltage) l Rise time (rated output voltage 10%-90% with rated resistive load) l Dropout time (rated output voltage 90%-10% with rated resistive load) l Dynamic recovery time (time for the output voltage to recover within 0.1%+10mV of the rated output when the load varies from 50% to 100% of the rated output current) |
||||||||
■ Rated output: 0-80V/0-12.5A (360W)
■ Wide-range operation, constant power output
■ High efficiency and high power density
■ Programmable internal resistor to emulate battery outputs
■ Constant current priority mode to reduce voltage and current overshoot when powering LEDs
■ Master-slave serial-parallel operation
■ 24-bit color 4.3-inch color LCD display
■ Numeric keypad operation
■ Knobs for coarse and fine adjustment of voltage and current values
■ Timing output time (0-3600.0s)
■ Rise time of programmable voltage or current
■ RS232, USB HOST, USB DEVICE, LAN, analog control interface
▪ Generic testing for R&D and design verification
▪ New energy Solar cells, new power vehicles, electric bicycles
▪ Routine testing and maintenance of production line benches
■ Automated equipment integration testing
▪ Solar photovoltaic simulation testing
▪ Teaching laboratories
■ LED testing
| standard equipment | |||||
| Accessory Name | model number | ||||
| 26 pole analog control interface (TH6700) | TH26081 | ||||
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.