Vector network analyzers (VNAs) are test instruments that measure electrical network parameters. They are essential for radio frequency (RF) and microwave component analysis of a wide variety of passive and active devices including filters, antennas and power amplifiers.
Network analyzers are ideal for transmission, reflection and impedance measurements as well as s-parameter measurements during design and production.
Network analyzers can be used to characterize radio frequency (RF) devices. Although initially only measuring S-parameters, network analyzers are now highly integrated and advanced in order to outperform the device under test.
Let's take a look at the basics of network analysis and then see what other advanced measurements a network analyzer can perform.
What is a network analyzer?
Network analyzers can be used to characterize radio frequency (RF) devices. Although initially only measuring S-parameters, in order to outperform the device under test, today'snetwork analyzerAlready highly integrated and very advanced.
RF circuits require unique test methods. Voltages and currents are difficult to measure directly at high frequencies, so when measuring high-frequency devices, they must be characterized by how they respond to RF signals. Network analyzers characterize devices by sending known signals to the device and then making constant ratio measurements of the input and output signals.
Early network analyzers only measured amplitude. These scalar network analyzers could measure return loss, gain, VSWR, and perform a number of other amplitude-based measurements.
Most network analyzers today are vector network analyzers-measuring both amplitude and phase. Vector network analyzers are an extremely versatile class of instruments that can characterize S-parameters, match complex impedances, and make time-domain measurements.
For example, the PNA-X Vector Network Analyzer is a high-end network analyzer.
The high-level block diagram of this measurement example shows that there is a signal sent in the forward direction through the input of the device under test to the output. The measurement from the input to the output of the device is referred to as theForward measurementThe
The receiver side of the network analyzer measures the incident, reflected and transmitted signals in order to calculate the forward S-parameters.
Block Diagram of a General Purpose Network Analyzer
Key Specifications of Vector Network Analyzers
Vector network analyzers are both signal generators and receivers, so they have a large number of very necessary technical specifications. In this section, you will learn about some of the key technical specifications of network analyzers.
Maximum frequency
The maximum frequency of a VNA is the highest frequency it can measure. The receiver side of a network analyzer has an analog-to-digital converter (ADC) that converts the input signals into digital format. These signals can then be analyzed and displayed. However, the ADC does not have the ability to convert signals in the RF range, so the incident signal must be downconverted to its operating frequency. This operating frequency is called the intermediate frequency (IF).
dynamic range
Dynamic range is the range of power over which the response of a component can be measured.
This figure shows two different ways of defining dynamic range. The system dynamic range is the value used for instrument specifications.
The system dynamic range is the function of the instrument when no boost amplifier is used and the gain of the device under test is not taken into account. The maximum source power of an instrument is its maximum power level, Pref
The receiver dynamic range is the dynamic range of the instrument when power amplification is used. Unlike using the source power as the maximum power level, this specification is based on the maximum power Pmax that can be measured at the receiving end of the instrument.
Defining the dynamic range
A trace measured by the bandpass filter S21, which shows the dynamic range of the instrument, is shown in the lower left-hand plot. The upper limit of the trace is relatively flat and the lower limit contains some noise. Let's look at what factors determine the shape of these boundaries.
The maximum power level of the dynamic range is determined by the upper limit of the source power level and the compression point of the receiver.
The mixers and amplifiers that make up a receiver can only handle so much power before they reach saturation, or before they reach maximum output. When a device is in the saturation region, there is no longer a linear relationship between its input and output.
The saturation of the amplifier can be seen in the right-hand diagram below. At input powers higher than 1W, the actual output (red) will deviate from the desired output (green). This phenomenon is called compression. The receiver cannot capture the signal from any device output above its compression point. This limitation of the input power constitutes the upper limit of the dynamic range.
Dynamic range of traces In the gain compression plot, the ideal linear transfer function of the amplifier is shown in green and the true transfer function is shown in red.
output power
Output power reflects how much power the VNA's signal generator and tester can transmit into the device under test. It is expressed in dBm and is referenced to 50Ω impedance to match the characteristic impedance of most RF transmission lines.
High output power is useful for improving the signal-to-noise ratio of a measurement or determining the compression limits of the device under test.
Many active devices, such as amplifiers, require extremely challenging linear and nonlinear high power measurements beyond the power limits of the network analyzer.
trace noise
Trace noise is the superimposed noise you see forming on the response of the device under test due to random noise in the system. It can make the signal look less smooth and even a little jittery.
Trace noise can be eliminated by increasing the test power, decreasing the bandwidth of the receiver, or averaging.
The article will cover the basics of impedance and points of measurement. Impedance is the resistance of an AC circuit and is invisible. Therefore, it must be measured using a specialized measuring instrument such as an impedance tester. People who have never touched an impedance tester before may be more concerned about how to use it and what to look for when using it. Therefore, this article will present in an easy-to-understand way the...
A network analyzer consists of a signal source and a receiver. The receiver will detect changes in the output signal of the device (or network) and then compare it to the source signal fed into the device. To evaluate the effect of the device on current and voltage, the VNA measures the resulting amplitude and phase response. This results in transmission and reflection measurements, impedance and s-parameters, which can be used by the test engineer to...
An oscilloscope uses a probe to connect to a test point in a circuit and amplify or attenuate the voltage at that point. The subsequent signal path depends on the oscilloscope, but in general, analog circuits condition the signal and analog-to-digital converters digitize it for further evaluation, processing, and analysis. ,
To connect two DC power supplies in series, connect the positive terminal of the first power supply to the negative terminal of the second power supply to form a "daisy-chain" connection, where the series voltage is the sum of the voltages of the two power supplies. To connect two DC power supplies in series, proceed as follows: Note that the voltage of the load should be equal to or higher than the sum of the voltages of the two power supplies to prevent damage to the load or power supply. In addition, the load's rated...