Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A
Memory Recorder MR8847A

Memory Recorder MR8847A

With recorder + waveform generator function
Globalized Benchmarking Product Recorder for Field and R&D Trials

Categories. , Tags. , Brand.

Inquire about this product

:: Newly added 3 types of units, corresponding to all 17 units
● Generation and recording in one, reproducing the problematic waveforms measured at the output.
● High voltage 1000V direct input measurement (1MS/s, 16bit resolution)
● 20 MS/s high-speed sampling with channel-to-channel isolation (maximum sampling speed when U8975, U8977 or U8978 is installed: 10 MS/s)
● Analog 32ch + Logic Standard 16ch ~ Analog 20ch + Logic 64ch
:: Waveform judgment function utilizing high-speed sampling
● Oil- and dirt-resistant keypad design for on-site measurements
● One-touch operation, 50mm/s high-speed printing

Basic parameters

Number of input channels [8 analog units].16 analog channels + 16 logic channels (standard)
[5 analog units + 3 logic units].10 analog channels + 64 logic channels (standard 16 channels + logic unit has 48 channels)
*Analog modules, channel-to-channel insulation, insulation to ground
Logic modules and overall standard logic channels, all channels common ground
measuring range
(20 f.s.)
When using 8966: 5mV~20V/div, 12 ranges; Resolution: 1/100 of range
When using MR8990: 5 mV~50 V/div, 5 ranges, Decomposition energy: 1/1,000000 of the range.
When using U8974: 200 mV to 50 V/div, 8 ranges; Resolution: 1/1600 of range
Maximum Input Voltage When using 8966: DC 400V, when using MR8990: DC500V, when using U8974: DC1000V
frequency characteristic When using 8966: DC ~ 5MHz, when using MR8990: DC dedicated, when using U8974: DC ~ 100kHz
Timeline of storage functions
(when using the storage function)
5μs~5 minutes/graph, 26 ranges, 100 points/graph resolution, 3 time axis magnification 2×~10×, 13 time axis compression 1/2×~1/20,000×.
External Control Terminal External trigger input, trigger output, external sample input, external output 2 terminals (GO, NG), external input 3 terminals (START, STOP, PRINT)
measurement function Storage (High Speed Recording), Recording (Real Time Recording), X-Y Recording (X-Y Real Time Recording), FFT
Other Functions Waveform judgment (when storing, X-Y recording or FFT function))
Memory capacity MR8847-51: Total 64MW, 32MW/ch (2ch) to 4MW/ch (16ch)
MR8847-52: Total 256MW, 128MW/ch (2ch) to 16MW/ch (16ch)
MR8847-53: Total 512MW, 256MW/ch (2ch) to 32MW/ch (16ch)
Save Media CF card × 1: max. 2GB, hard disk (memory option, 80GB), USB flash drive (USB2.0)
recording paper 216mm x 30m, thermal paper on roll, recording speed: 50mm/sec max.
monitor 10.4-inch TFT color LCD (SVGA, 800 x 600 dots)
connector [LAN].100BASE-TX; Features: DHCP, DNS, FTP, HTTP
[USB]. USB2.0, socket A x 1 , socket B x 1 (test data input to PC, communication control)
power supply (of an appliance etc) AC 100 to 240V, 50/60Hz (130VA max., 220VA max. when using a print unit)
DC 10 to 28V system (when using DC power supply unit 9784)
Volume and weight 351mm × 261mm × 140Dmm, 7.6kg (main unit only)
attachment (email) Instruction manual × 1, Measurement guide × 1, Application CD-ROM (Waveform creation software SF8000, Waveform viewing software Wv/Command table), Power cord × 1, Input cable label × 1, USB cable x 1, Recording paper × 1, Paper roll accessory × 2, Ferrite bead × 1