The TH6600L series integrates a powerful 15kW electronic load in a 3U volume, with energy efficiently fed back into the grid.
TH6600L series utilizes the master-slave mode to support parallel, active equalization, power up to 480kW, built-in function generator, free to generate arbitrary waveforms, and can be imported through the USB interface LIST to generate waveforms! With high reliability, efficient setup function and rich measurement function.
TH6600L series is widely used in many fields such as high power battery, automotive electronics, green energy, high-speed testing, etc. It is a product series with comprehensive functions, excellent performance and wide adaptability!
TH6600L series adopts 7-inch TFT capacitive touch screen with unique human interaction experience, displaying richer information and setting parameters more conveniently, and with multi-CPU processing architecture, making the user response more timely. With standard 3U height and 19-inch rack width, it is convenient for customers to set up their own test system!
Quick Selection
model number | input voltage | amps | power (output) |
TH6680L-120-05 | 80V | 120A | 5kW |
TH6680L-240-10 | 80V | 240A | 10kW |
TH6680L-360-15 | 80V | 360A | 15kW |
TH66200L-70-05 | 200V | 70A | 5kW |
TH66200L-140-10 | 200V | 140A | 10kW |
TH66200L-210-15 | 200V | 210A | 15kW |
TH66500L-30-05 | 500V | 30A | 5kW |
TH66500L-60-10 | 500V | 60A | 10kW |
TH66500L-90-15 | 500V | 90A | 15kW |
TH66750L-20-05 | 750V | 20A | 5kW |
TH66750L-40-10 | 750V | 40A | 10kW |
TH66750L-60-15 | 750V | 60A | 15kW |
TH661000L-40-15 | 1000V | 40A | 15kW |
Technical Parameters
A. Feedback energy absorption
TH6600L series feed-back programmable high-power DC electronic load with feed-back energy absorption function, up to 93% energy feedback efficiency, can be directly returned to the power network directly after the use of electricity, rather than ordinary power supplies as directly as thermal energy consumption, greatly reducing the cost of electricity users.
Due to its direct electrical energy feedback, it avoids the large volume and heat of the instrument brought about by thermal energy consumption, as well as the expenses brought about by the use of air conditioning or other refrigeration systems in order to emit heat; it also reduces noise and avoids the greenhouse gases or hazardous gases produced in the process of refrigeration, which are harmful to the environment.
Another benefit of the feed-back feature is that a single unit can deliver high power in a small footprint (up to 15kW in a standard size of 3U height), which greatly saves the volume required to house the instrument.
B. Master-Slave Mode Parallel with Extended Inputs
Since a single machine supports a maximum input of 360A and a maximum power of 15kW, for higher power or current outputs, it is necessary to output multiple instruments of the same model in parallel.
TH6600L series supports parallel operation in the mode of master and slave. If more than one instrument is in parallel, one of them should be set as the master, and the rest of the instruments should be set as slaves, so that all the slaves can be controlled by the master, and the whole parallel system can be regarded as a single instrument operation at this time.
Master-slave mode parallel support for 1 mainframe, up to 15 standalone units, and a total of 16 units.
C. Data logging function, timing function
During product testing, it is often necessary to record product measurement parameters in real time for product quality analysis or test result traceability.
The built-in data logging function of TH6600L series supports to record the current measured voltage, current, power, resistance, etc. of the instrument to the cache by time interval, set the number of records or timer, and automatically save the test results to an external USB flash disk with CSV file format.
The timing function supports cutting off instrument outputs/inputs in a countdown mode.
D. Built-in function generator
The TH6600L series has a built-in true function generator applied to output voltage or output current.
The instrument has built-in standard waveforms such as sine, triangle, square and trapezoidal waveforms, which can be recalled and output at any time.
The instrument supports test sequences or arbitrary signal generators to generate more complex function signals, which can be divided into 99 groups of sequences for R&D and product testing. The generated function signals and sequences can be stored to a USB flash drive for easy recall.
E. Advanced Functions: List Test
The TH6600L series advanced features support list testing, for those who need complex test steps, they can be performed through a list test sequence.
The list test supports source/carrier voltage, source current, carrier current and time settings, and up to 99 groups of test sequences can be set, and the test sequences can generate arbitrary wave files for function signal generator to call.
F.Advanced Functions: Battery Test
The TH6600L series advanced features support battery or supercapacitor testing with 2 integrated test methods.
- static test
Static testing of the discharge process and capacity
- Dynamic testing
Test dynamic discharge, dynamic test, can test the dynamic characteristics of the battery
G. Advanced Features:PVbeta (software)
TH6600L series advanced function supports PV PV test function and easy testing of PV panel PV function.
Simple PV testing is relatively simple, requiring only the setting of Uoc (open circuit voltage), Isc (short circuit current), Umpp (voltage at the maximum power point) and Impp (current at the maximum power point).
After loading and running, the interface can be loaded at any time to change the illumination value, that is, the corresponding output value can be obtained.
H. Advanced Features:MTTPMaximum power point tracking test
Since the PV Simple PV Test function is too simple to automatically track the PV maximum power point, the TH6600L series provides an advanced MTTP function to automatically track the PV maximum power point.
The MTTP function supports the following four test methods:
- MPPT1: Find the maximum power point, stop when found
- MPPT2: Quickly find the maximum power point, after finding it, track the maximum power point in real time according to the set value.
- MPPT3: Real-time tracking of maximum power points based on input maximum power points
- MPPT4: Read the relevant .CSV file on the USB flash drive to find the maximum power point in the customer's setpoints
After loading and running, the corresponding maximum power point can be obtained.
model number | TH6680L-120-05 | TH6680L-240-10 | TH6680L-360-15 | |
Rated Input (Load Mode) | power (output) | 0-5kW | 0-10kW | 0-15kW |
input voltage | 0-80V | 0-80V | 0-80V | |
amps | 0-120A | 0-240A | 0-360A | |
internal resistance | 0.02-25Ω | 0.01-13Ω | 0.006-10Ω | |
Setting resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.1A | 0.1A | 0.1A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.001Ω | 0.001Ω | 0.001Ω | |
Readback resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.1A | 0.1A | 0.1A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.001Ω | 0.001Ω | 0.001Ω | |
Setpoint accuracy
December (25°C±5°C) |
input voltage | ≤0.1%FS | ≤0.1%FS | ≤0.1%FS |
amps | ≤0.2%FS | ≤0.2%FS | ≤0.2%FS | |
power (output) | ≤1%FS | ≤1%FS | ≤1%FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Readback accuracy
December (25°C±5°C) |
input voltage | ≤0.2%FS | ≤0.2%FS | ≤0.2%FS |
amps | ≤0.2%FS | ≤0.2%FS | ≤0.2%FS | |
power (output) | ≤1%FS | ≤1%FS | ≤1%FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Remote sensing compensation | ≤5% FS | |||
Energy Return Efficiency | ≤93% | |||
Volume and weight | Housing Dimension(WxHxD)mm | 430×133×703.5 | ||
Overall dimensions (WxHxD)mm | 483×133×793.5 | |||
Weight (net) | 18.5kg | 25.5kg | 32.5kg | |
Power supply | 342VAC-528VAC, 44-66Hz | |||
model number | TH66200L-70-05 | TH66200L-140-10 | TH66200L-210-15 | |
Rated Input (Load Mode) | power (output) | 0-5kW | 0-10kW | 0-15kW |
input voltage | 0-200V | 0-200V | 0-200V | |
amps | 0-70A | 0-140A | 0-210A | |
internal resistance | 0.1-150Ω | 0.05-75Ω | 0.033-50Ω | |
Setting resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.01A | 0.01A | 0.01A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.01Ω | 0.01Ω | 0.01Ω | |
Readback resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.01A | 0.01A | 0.01A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.0001Ω | 0.0001Ω | 0.0001Ω | |
Setpoint accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ≤0.1% FS | ≤0.1% FS |
amps | ≤0.2% FS | ≤0.2% FS | ≤0.2% FS | |
power (output) | ≤1% FS | ≤1% FS | ≤1% FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Readback accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ≤0.1% FS | ≤0.1% FS |
amps | ≤0.2% FS | ≤0.2% FS | ≤0.2% FS | |
power (output) | ≤1% FS | ≤1% FS | ≤1% FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Remote sensing compensation | ≤5% FS | |||
Energy Return Efficiency | ≤93% | |||
Volume and weight | Housing Dimension(WxHxD)mm | 430×133×703.5 | ||
Overall dimensions (WxHxD)mm | 483×133×793.5 | |||
Weight (net) | 18.5kg | 25.5kg | 32.5kg | |
Power supply | 342VAC-528VAC, 44-66Hz | |||
model number | TH66500L-30-05 | TH66500L-60-10 | TH66500L-90-15 | |
Rated Input (Load Mode) | power (output) | 0-5kW | 0-10kW | 0-15kW |
input voltage | 0-500V | 0-500V | 0-200V | |
amps | 0-30A | 0-60A | 0-90A | |
internal resistance | 0.5-1000Ω | 0.25-500Ω | 0.16-340Ω | |
Setting resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.01A | 0.01A | 0.01A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.01Ω | 0.01Ω | 0.01Ω | |
Readback resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.01A | 0.01A | 0.01A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.0001Ω | 0.0001Ω | 0.0001Ω | |
Setpoint accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ≤0.1% FS | ≤0.1% FS |
amps | ≤0.2% FS | ≤0.2% FS | ≤0.2% FS | |
power (output) | ≤1% FS | ≤1% FS | ≤1% FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Readback accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ≤0.1% FS | ≤0.1% FS |
amps | ≤0.2% FS | ≤0.2% FS | ≤0.2% FS | |
power (output) | ≤1% FS | ≤1% FS | ≤1% FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Remote sensing compensation | ≤5% | |||
Energy Return Efficiency | ≤93% | |||
Volume and weight | Housing Dimension(WxHxD)mm | 430×133×703.5 | ||
Overall dimensions (WxHxD)mm | 483×133×793.5 | |||
Weight (net) | 18.5kg | 25.5kg | 32.5kg | |
Power supply | 342VAC-528VAC, 44-66Hz | |||
model number | TH66750L-20-05 | TH66750L-40-10 | TH66750L-60-15 | |
Rated Input (Load Mode) | power (output) | 0-5kW | 0-10kW | 0-15kW |
input voltage | 0-750V | 0-750V | 0-750V | |
amps | 0-20A | 0-40A | 0-60A | |
internal resistance | 1.2-2200Ω | 0.6-1100Ω | 0.4-740Ω | |
Setting resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.01A | 0.01A | 0.01A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.01Ω | 0.01Ω | 0.01Ω | |
Readback resolution | input voltage | 10mV | 10mV | 10mV |
amps | 0.01A | 0.01A | 0.01A | |
power (output) | 1W | 1W | 1W | |
internal resistance | 0.0001Ω | 0.0001Ω | 0.0001Ω | |
Setpoint accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ≤0.1% FS | ≤0.1% FS |
amps | ≤0.2% FS | ≤0.2% FS | ≤0.2% FS | |
power (output) | ≤1% FS | ≤1% FS | ≤1% FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Readback accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ≤0.1% FS | ≤0.1% FS |
amps | ≤0.2% FS | ≤0.2% FS | ≤0.2% FS | |
power (output) | ≤1% FS | ≤1% FS | ≤1% FS | |
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Remote sensing compensation | ≤5% | |||
Energy Return Efficiency | ≤93% | |||
Volume and weight | Housing Dimension(WxHxD)mm | 430×133×703.5 | ||
Overall dimensions (WxHxD)mm | 483×133×793.5 | |||
Weight (net) | 18.5kg | 25.5kg | 32.5kg | |
Power supply | 342VAC-528VAC, 44-66Hz | |||
model number | TH661000L-40-15 | |||
Rated Input (Load Mode) | power (output) | 0-15kW | ||
input voltage | 0-1000V | |||
amps | 0-40A | |||
internal resistance | 0.8-1300Ω | |||
Setting resolution | input voltage | 10mV | ||
amps | 0.01A | |||
power (output) | 1W | |||
internal resistance | 0.01Ω | |||
Readback resolution | input voltage | 10mV | ||
amps | 0.01A | |||
power (output) | 1W | |||
internal resistance | 0.0001Ω | |||
Setpoint accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ||
amps | ≤0.2% FS | |||
power (output) | ≤1% FS | |||
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Readback accuracy
December (25°C±5°C) |
input voltage | ≤0.1% FS | ||
amps | ≤0.2% FS | |||
power (output) | ≤1% FS | |||
internal resistance | ≤ 1% of maximum resistance ± 1% of maximum current | |||
Remote sensing compensation | ≤5% FS | |||
Energy Return Efficiency | ≤93% | |||
Volume and weight | Housing Dimension(WxHxD)mm | 430×133×703.5 | ||
Overall dimensions (WxHxD)mm | 483×133×793.5 | |||
Weight (net) | 32.5kg | |||
Power supply | 342VAC-528VAC, 44-66Hz |
■ Rated input: 500V/60A/10kW
■ High power density: 3U high stand-alone power 5kW/10kW/15kW
■ Paralleling in master-slave mode, expandable up to 480 kW
■ High accuracy and resolution
■ Load mode supports automatic conversion of CV, CC, CR, CP
■ Built-in function generator: built-in sine, triangle, arbitrary waveforms, support for customized waveforms
■ 7-inch 24-bit color TFT LCD capacitive touch screen with 800 x 480 resolution
■ Linux operating underpinnings, English and Chinese interfaces
■ PV simulation tests: simple PV test, MPPT maximum power point tracking
■ Data recording function: real-time recording of voltage, current and other information, and save to U disk
■ USB flash drive upgrade: Updates are realized by upgrading the instrument system with a USB flash drive.
■ Supports knob and cursor for precise fine-tuning of values.
■ Intelligent fan control saves energy and reduces noise
■ Timing/timing function: Timing or timing of instrument outputs
■ Analog interface: for external analog control
■ Protection: comes with hardware OVP, OCP, OPP and other protection, can be customized alarm events
■ Support for SCPI and MODBUS protocols
▪ Generic testing for R&D and design verification
▪ New energy: solar cells, new electric vehicles, electric bicycles
▪ Routine testing and maintenance of production line benches
■ Automated equipment integration testing
▪ Solar photovoltaic simulation testing
▪ Teaching laboratories
■ LED testing
■ Automotive Harness Reliability Testing