Product Overview: Fluke 707 Loop Calibrator
The Fluke 707 Loop Calibrator (Loop Calibrator), an ultra-fast handheld tool for loop calibration, is a high-performance solution for calibrating, repairing and maintaining current loops. Its new Quick Click knob makes measurements fast and easy to use. Key features of the Loop Calibrator include: one-handed operation with Quick Click sensing knob; mA power supply, simulation and measurement functions; 0.015% accuracy and 0.001 mA resolution; simultaneous display of mA and percentage of width; optional step and ramp outputs; 24 V loop power supply for mA measurements, including 250 Ω HART resistors. Includes 250 Ω HART resistor 0-28 DC voltage measurement; check loop voltage. The compact design allows the Fluke 707 Loop Calibrator to be easily replaced without opening the battery cover, and provides you with a removable protective cover and a three-year warranty.
Product Specification: Fluke 707 Loop Calibrator
| Technical indicators | ||
| Current Measurement | range (of scales or measuring equipment) | 0 to 24 mA |
| resolution (of a photo) | 0.001 mA | |
| accurate | 0.015% + 2 LSD of reading | |
| current output | range (of scales or measuring equipment) | 0 to 20 mA or 4 to 20 mA |
| accurate | 0.015% + 2 LSD of reading | |
| driving ability | 1200 Ω at 20 mA in HART mode 950 Ω | |
| Current simulation | range (of scales or measuring equipment) | 0 to 20 mA or 4 to 20 mA |
| accurate | 0.015% + 2 LSD of reading | |
| External circuit voltage requirements | 12-30 V | |
| circuit power | 24 V when measuring mA | |
| Voltage measurement | range (of scales or measuring equipment) | 0 to 28 VDC |
| resolution (of a photo) | 1 mV | |
| accurate | 0.015% + 2 LSD of reading | |
| Environmental indicators | ||
| operating temperature | -10 °C to 55 °C | |
| storage temperature | -30 °C to 60 °C | |
| Humidity (non-condensing) | 0 to 90% (0 °C to 35 °C); 0 to 70% (35 °C to 55 °C) | |
| temperature coefficient | -10 °C to 18 °C, 28 °C to 55 °C, ±005%/°C of range | |
| Safety specifications | ||
| surety | CSA C22.2 No.1010.1:1992 | |
| Electromagnetic Compatibility (EMC) | EN50082-1:1992 and EN55022:1994 Class B | |
| Maximum voltage | 30 V | |
| Mechanical and general specifications | ||
| sizes | 152 x 70 x 41 mm | |
| weights | 224 g (340 g with holster) | |
| batteries | One 9 V alkaline battery | |
| warranty period | third year | |
| Shock and vibration | Specification for Level 2 instruments according to MIL-T-28800 (military specification) | |
| Display current and range ratio ( %) | there are | |
| Auto Step, Auto Slope | there are | |
| Span Check | there are | |