Product Overview: Fluke 1732 and 1734 Handheld Three-Phase Power Meters
Which three-phase recorder is right for you?
| Three-phase power meter | Power Quality Recorder | |||
|---|---|---|---|---|
| functionality | 1732 Handheld Three-Phase Power Meter | 1734 Handheld Three-Phase Power Meter | 1736 Power quality recorders | 1738 Power quality recorders |
| Load Research | - | - | - | - |
| Energy consumption assessment | - | - | - | - |
| Neutral line current measurement (four current channels) | - | - | ||
| Harmonic Measurement | - | - | ||
| Capture voltage events | - | - | ||
| Advanced Analytics: Waveform and surge event capture PQ Health status (EN51060) |
Upgrade package* | - | ||
| IEEE519 Total Harmonic Distortion Measurement | selectable | selectable | ||
| Fully integrated with Fluke Connect® for logging | Upgrade package* | - | Upgrade package* | - |
| WiFi | selectable | - | - | - |
| Wi-Fi / Bluetooth | selectable | - | selectable | - |
| Magnetic Probe Kit | selectable | - | selectable | - |
| Magnetic Hooks | selectable | - | selectable | - |
| Connect via WiFi wireless router | A free software license is required for product registration. | A free software license is required for product registration. | ||
*The upgrade kit can be used to upgrade an existing 1732 Handheld 3-Phase Power Meter that has the same functionality as the 1734 Handheld 3-Phase Power Meter, and can also be used to upgrade an existing 1736 Power Quality Recorder that has the same functionality as the 1738 Advanced Power Quality Recorder. Note that the 1732 and 1734 handheld three-phase wattmeters cannot be upgraded to function as the 1736 and 1738 Power Quality Loggers.
Please consult your dealer for more information on upgrade packages.
Please consult your dealer for more information on upgrade packages.
The Fluke 1732 and 1734 Handheld 3-Phase Power Meters introduce a new and simple way to help users identify the source of wasted energy consumption. Find out where energy is being consumed in your facility - all locations including incoming wires and individual circuits - and at what moment it is being consumed. Remotely accessing data and sharing it with your team through the Fluke Connect® app allows you to maintain a safer working distance and make important decisions in real time, reducing the need to use protective gear, field trips and inspections in the field.
Analyzing energy usage in your facility helps you identify energy-saving opportunities and gives you data on which to base your actions. The new Energy Analytics software package allows you to compare multiple data points over time to get a complete picture of energy use, which is the first step in reducing energy costs.
Product Specification: Fluke 1732 and 1734 Handheld Three-Phase Power Meters
| Technical indicators | |||||
| accurate | |||||
| parameters | range (of scales or measuring equipment) | resolution (of a photo) | Intrinsic accuracy at reference conditions (% reading + % range) | ||
| input voltage | 1000 V | 0.1 V | ±(0.2% + 0.01%) | ||
| Current: direct input | i17xx-flex 1500 12" | 150 A | 0.1 A | ±(1% + 0.02%) | |
| 1500 A | 1 A | ±(1% + 0.02%) | |||
| i17xx-flex 3000 24" | 300 A | 1 A | ±(1% + 0.03%) | ||
| 3000 A | 10 A | ±(1% + 0.03%) | |||
| i17xx-flex 6000 36" | 600 A | 1 A | ±(1.5% + 0.03%) | ||
| 6000 A | 10 A | ±(1.5% + 0.03%) | |||
| i40s-EL Current Clamp | 4 A | 1 mA | ±(0.7% + 0.02%) | ||
| 40 A | 10 mA | ±(0.7% + 0.02%) | |||
| frequency | 42.5 Hz to 69 Hz | 0.01 Hz | ± (0.1%) | ||
| auxiliary input | ±10 VDC | 0.1 mV | ±(0.2% + 0.02%) | ||
| Voltage min/max | 1000 V | 0.1 V | ±(1% + 0.1%) | ||
| Current min/max | Defined by Annex | Defined by Annex | ±(5% + 0.2%) | ||
| Voltage THD | 1000% | 0.1% | ±0.5 | ||
| Current THD | 1000% | 0.1% | ±0.5 | ||
| Inherent Uncertainty ± (% of reading + % of range)¹ | |||||
| parameters | magnitude of impact | iFlex 1500-12 | iFlex 3000-24 | iFlex 6000-36 | i40S-EL |
| 150 A / 1500 A | 300 A / 3000 A | 600 A / 6000 A | 4 A / 40 A | ||
| Active power P | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
| Active energy Ea | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
| Apparent power S | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
| Apparent energy Eap | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
| Reactive power Q | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
| Reactive energy Er | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
| Power factor PF | - | ±0.025 | |||
| Displacement power factor | - | ±0.025 | |||
| DPF/cosϕ | - | ±0.025 | |||
| Additional uncertainty in range¹ | V P-N>250 V | 0.015% | 0.0225% | 0.0225% | 0.015% |
| ¹ Range = 1000 V x current range Reference conditions:
|
|||||
| Electrical specifications | |
| power supply | |
| Voltage range | 100 V to 500 V when supplied via the measuring circuit with a safe input plug |
| 100 V to 240 V with standard power cord (IEC 60320 C7) | |
| power wastage | 50 VA maximum (15 VA maximum with IEC 60320 input) |
| energy efficiency | ≥ 68.2% (energy efficiency code compliant) |
| Maximum no-load loss | < 0.3 W (only when using IEC 60320 inputs) |
| Mains frequency | 50/60 Hz ± 15% |
| batteries | Lithium-ion battery 3.7 V, 9.25 Wh (customer replaceable) |
| Battery powered runtime | 4 hours in standard operating mode, up to 5.5 hours in power saving mode |
| charging time | < 6 hours |
| data acquisition | |
| resolution (of a photo) | 16-bit synchronized sampling |
| sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to power supply frequency |
| Input Signal Frequency | 50/60 Hz (42.5 to 69 Hz) |
| Type of wiring method | 1-φ, 1-φ IT, split-phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balance, 3-φ Aron/Blondel (two-meter method), 3-φ open-leg delta, current only (load analysis) |
| data storage | Internal flash memory (not user replaceable) |
| Memory capacity | Typical: 10 logged sessions of 8 weeks, 1 minute intervals, and 500 events¹. |
| ¹The number of possible logging sessions and logging periods depends on the user's needs. | |
| fundamental interval | |
| Parameters measured | Voltage, Current, Aux, Frequency, THD V, THD A, Power, Power Factor, Base Wave Power, DPF, Electrical Energy |
| Average interval | 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Average time min/max | Voltage, current: full cycle updated every half week RMS Auxiliary power: 200ms |
| Demand interval (energy meter mode) | |
| Parameters measured | Electrical energy (Wh, varh, VAh), PF, maximum demand, cost of electrical energy |
| intervals | 5 min, 10 min, 15 min, 20 min, 30 min, off |
| standards-compliant | |
| power (output) | IEEE 1459 |
| communication interface | |
| USB-A | File transfer via USB flash drive, firmware update Maximum current: 120 mA |
| WiFi | File transfer and remote control via direct connection or WiFi network |
| bluetooth | Reading Auxiliary Measurement Data from Fluke Connect® 3000 Series Modules (requires 1734 or 1732 upgrade option) |
| USB-mini | Download data to PC |
| Voltage Input | |
| input channel | 4 (three-phase and zero line) |
| Maximum Input Voltage | 1000 Vrms, CF 1.7 |
| Input Impedance | 10 MΩ |
| Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz |
| resizing | 1:1, variable |
| Voltage safety level | 1000 V CAT III/600 V CAT IV |
| Current Input | |
| input channel | 3, automatic mode selection for connected sensors |
| Input Voltage | Current clamp input: 500 mVrms/50 mVrms; crest factor 2.8 |
| Rogowski Roche Coil Input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; crest factor 4; all within probe rated range |
| range (of scales or measuring equipment) | Using the Fine Flex Current Probe i17XX-flex1500 12 for 1 A to 150 A/10 A to 1500 A |
| Using the fine flexible current probe i17XX-flex3000 24 for 3 A to 300 A/30 A to 3000 A | |
| Using the Fine Flex Current Probe i17XX-flex6000 36 for 6 A to 600 A/60 A to 6000 A | |
| 40 mA to 4 A/0.4 A to 40 A (40 A Current Clamp i40s-EL) | |
| Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz |
| resizing | 1:1, variable |
| auxiliary input | |
| input channel | ="2" |
| Input range | 0 to ± 10 VDC, 1 reading/second |
| Variation factor (applicable from 2014) | Format: mx + b (gain and offset) user configurable |
| Unit display (applicable from 2014) | User configurable (7 characters, e.g. °C, psi or m/s) |
| wireless connection | |
| input channel | ="2" |
| Supported Modules | Fluke Connect® 3000 Series |
| harvest | 1 reading/second |
| Environmental indicators | |
| operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
| storage temperature | -20 °C to +60 °C (-4 °F to 140 °F) including battery: -20 °C to +50 °C (-4 °F to 122 °F) |
| Operating humidity | 10 °C to 30 °C (50 °F to 86 °F) Maximum relative humidity 95% |
| 30 °C to 40 °C (86 °F to 104 °F) Maximum relative humidity 75% | |
| 40 °C to 50 °C (104 °F to 122 °F) Maximum relative humidity 45% | |
| Working altitude | 2000 m (down to 1000 V CAT II/600 V CAT III/300 V CAT IV up to 4000 m) |
| Storage altitude | 12,000m |
| housings | IP50 (in accordance with EN60529) |
| vibration testing | MIL-T-28800E, Type 3, Class III, Type B |
| safety | IEC 61010-1 |
| IEC power input: overvoltage category II, pollution class 2 | |
| Voltage side: Overvoltage category IV, pollution class 2 | |
| IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V | |
| electromagnetic compatibility | EN 61326-1: Industry CISPR 11: Group 1, Class A |
| Korea (KCC): Class A equipment (industrial broadcasting and communications equipment) | |
| USA (FCC): 47 CFR 15 Part B. This product is considered tax-exempt equipment under Section 15.103. | |
| temperature coefficient | 0.1 x accuracy index/°C |
| General technical indicators | |
| Color LCD display | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch screen |
| warranty period | Instrument and power supply: two years (excluding batteries) |
| Annex: One year | |
| Calibration cycle: two years | |
| sizes | Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in) |
| Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in) | |
| When the instrument is connected to the power supply: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in) | |
| weights | Instrument: 1.1 kg (2.5 lb) |
| Power: 400 g (0.9 lb) | |
| tamper-proof | Anti-theft lock slot |
| i17xx-flex 1500 12 Flexible Current Probe Specifications | |
| measuring range | 1 to 150 A AC / 10 to 1500 A AC |
| lossless current | 100 kA (50/60 Hz) |
| Inherent error at reference conditions* | ±0.7% of reading |
| 173x + iFlex Accuracy | ± (1% of reading + 0.02% of range) |
| Temperature coefficients beyond the operating temperature range | 0.05%/°C of reading, 0.09%/°F of reading |
| operating voltage | 1000 V CAT III, 600 V CAT IV |
| Probe cable length | 305 mm (12 in) |
| Probe Cable Diameter | 7.5 mm (0.3 in) |
| Minimum bending radius | 38 mm (1.5 in) |
| Output cable length | 2 m (6.6 ft) |
| weights | 115 g |
| Probe Cable Material | TPR |
| Connector Material | POM + ABS/PC |
| output cable | TPR/PVC |
| operating temperature | Tested at a wire temperature of -20 °C to +70 °C (-4 °F to 158 °F), not exceeding 80 °C (176 °F) |
| Non-operating temperature | -40 °C to +80 °C (-40 °F to 176 °F) |
| Relative humidity in working condition | 15% to 85% Non-Condensing |
| IP rating | IEC 60529:IP50 |
| warranty period | 1 year |
* Reference conditions:
|
|
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.