Resistance Meter RM3545A
Resistance Meter RM3545A
Resistance Meter RM3545A
Resistance Meter RM3545A
Resistance Meter RM3545A
Resistance Meter RM3545A
Resistance Meter RM3545A
Resistance Meter RM3545A

Resistance Meter RM3545A

The new benchmark for full inspection. High-precision determination of whether the quality of welding and connection is qualified.
Newly equipped with a 1000 µΩ range and a minimum resolution of 1 nΩ. basic accuracy of 0.006% and a maximum measurement current of 1A.

Categories. , Tag. Brand.

Inquire about this product

:: Accurate measurement of low resistance values in the development of batteries, motors, electronic parts, and other research and development processes.

● Minimum measurement range: 1000 μΩ, Minimum measurement range accuracy: 0.045%, Minimum resolution: 1 nΩ, Maximum measurement current: 1 A

● The same measurement accuracy as at the time of development can be realized by integrating it into the production line

● Up to 132 channels (4-terminal method) (when combined with Scanner Module Rack SW1002)

● Supports up to 20 channels (4-terminal method) (When two Z3003 Multiplexer Units are installed. RM3545A-2 only)

● Measurement speed as fast as 21 ms (*1) in the low resistance test range.

 *1: 10 mΩ range or 100 mΩ range, PR mode ON, measurement speed FAST, with external trigger

Basic parameters (accuracy guaranteed for 1 year)

Resistance measurement range (13 ranges) [Range, Maximum display, Resolution, Measured current]

1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A

10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A

100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A

1000 mΩ: 1200.000 mΩ, 1 μΩ, 100 mA

10 Ω: 12.000 00 Ω, 10 μΩ, 10 mA

100 Ω: 120.000 0 Ω, 100 μΩ, 10 mA

1000 Ω: 1200.000 Ω, 1 mΩ, 1 mA

10 kΩ: 12.000 00 kΩ, 10 mΩ, 1 mA

100 kΩ: 120.000 0 kΩ, 100 mΩ, 100 μA

1000 kΩ: 1200.000 kΩ, 1 Ω, 10 μA

10 MΩ 12.000 00 MΩ, 10 Ω, 1 μA

100 MΩ (100 MΩ range high accuracy mode): 120.000 0 MΩ, 100 Ω, 100 nA

1000 MΩ: 1200.0 MΩ, 100 kΩ, 1 μA or less

Representative accuracy

※ High mode, OVC function ON, SLOW2, no zero adjustment

1000 μΩ range: ±0.045% rdg ±0.010 % f.s.

10 mΩ Range: ±0.045% rdg ±0.001 % f.s.

100 mΩ range: ±0.045% rdg ±0.001 % f.s.

1000 mΩ range: ±0.012% rdg ±0.001 % f.s.

1000 Ω range: ±0.006% rdg ±0.001 % f.s.

measured current High mode: 1000μΩ (1 A) ~ 1000 MΩ (1 μA or less)

Low Mode: 100 mΩ (100 mA) ~ 100 Ω (1 mA)

Low Power Mode (LP): Low power measurement with measurement current and open circuit voltage controlled at 20 mV

LP1000 mΩ (1 mA) to LP1000 Ω (5 μA)

Measurement speed fast, medium, slow1, slow2
Allowable Loop Resistance

*Reference value

Circuit resistance between SOURCE B and SOURCE A (other than the measurement object)

Range up to 100 mΩ (PR mode OFF): 2.6 Ω

Range below 100 mΩ (PR mode ON): 3.5 Ω

1000 mΩ range: 15 Ω

10 Ω range: 150 Ω

100 Ω Range: 100 Ω

10 kΩ range: 500 Ω

100 kΩ or more range: 1 kΩ

Maximum open terminal voltage Range up to 1000 Ω: 8.0 V

Range above 10 kΩ: 20 V

temperature measurement Thermistor sensor ( Z2001 [Accessory] ): -10.0°C ~ 99.9°C Analog input (infrared thermometer, etc.): DC 0 V ~ 2.0 V
Built-in multiplexer (built-in option, RM3545A-2 only) Multi-Converter Unit Z3003

Carrying capacity: up to 2 units

Maximum number of channels: 20 channels (4-wire), 42 channels (2-wire)

Switching time: 30 msec

External multiplexer (external option) Scanning Module Rack

Maximum number of channels (SW1001): 33 channels (4-wire type)

Maximum number of channels (SW1002): 132 channels (4-wire type)

Switching time: 11 msec

connector LAN (TCP/IP, 10BASE-T/100BASE-TX), RS-232C (up to 115200 bps, with printer I/F), USB, EXT I/O (D-sub 37 pins), analog output (D/A output voltage range, DC 0 V ~ 1.5 V)
functionality Contact check, Zeroing (within ±50%of full scale for each range) *1, No zeroing accuracy guarantee, OVC function, Contact improvement function (Max. applied voltage 5 V, Max. current 10 mA ), Low power mode (Max. open-circuit voltage 20 mV ), Temperature measurement function, Temperature compensation (TC) function, Temperature conversion (δt ) function, Statistical operation function, Delay function, averaging function, setting saving (panel saving), data storage function, command monitoring function (displaying the status of sending and receiving commands and queries), LabVIEW® driver support*2

*1: Non-zeroable above 100 MΩ (forced off)

*2: LabVIEW drivers are trademarks and registered trademarks of National Instruments, Inc.

power supply Rated power supply voltage: AC 100 V~240 V

Rated power frequency: 50 Hz / 60 Hz

Maximum power rating: 40 VA

Typical power consumption (reference value) 16 W (Measuring current 1 A, LCD light on)
Volume and weight RM3545A-1: approx. 215W × 80H × 306.5D mm (excluding protrusions), approx. 2.7 kg

RM3545A-2: approx. 215W × 80H × 306.5D mm (excluding protrusions), approx. 3.4 kg

attachment (email) Power cord x 1, Temperature sensor Z2001 x 1, Male connector for EXT I/O x 1, Connector cover for EXT I/O x 1, Spare fuse ( F1.6AH 250 V ) x 1, Startup guide x 1, Precautions for use x 1
Expand More
Resistance Meter RM3545AResistance Meter RM3545A

Click to enquire

Product consultation and purchase:18218718851

I already understand