| Number of measuring lines |
In addition to single-phase 2-wire/single-phase 3-wire/three-phase 3-wire/three-phase 4-wire, the additional ch4 measures voltage/current (DC or AC). |
| Voltage range |
ch1~ch3: voltage measurement 600.00Vrms, instantaneous voltage measurement peak 6.0000kV
ch4: 600.00Vrms or DC, instantaneous voltage measurement peak 6.0000kV |
| Current range |
AC500.00mA~5.0000kA (measurement range varies depending on the sensor used) |
| power range |
300.00W~3.0000MW (automatically determined by the voltage and current range used) |
| Basic precision |
Voltage: Standard voltage ±0.1% rdg.
Current: ±0.1% rdg. ±0.1% f.s. + Current Sensor Accuracy
Active power: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy |
| measurement function |
1,Instantaneous overvoltage: 2MHz sampling rate
2,Frequency 1 waveform: start operation from 1 waveform 200kHz sampling rate
3,Voltage 1/2 RMS: 1 waveform operation per staggered half waveform
Current 1/2 RMS: operation per half waveform
4,Voltage rise, voltage fall, instantaneous interruption: Detection at 1/2 RMS voltage
5, Impulse voltage: voltage 1/2 RMS detection
6,Voltage waveform comparison: automatically generate and compare the judgment area
7,Instantaneous flicker value: in accordance with IEC61000-4-15
8,Frequency 200ms: Run from 10 waveforms, 12 waveforms 40~70Hz
9,Frequency 10 seconds: Starting from the waveform of 10 seconds, 40~70Hz.
10,Voltage waveform peaks, current waveform peaks
11,Voltage, current, active power, apparent power, reactive power, active energy, reactive energy,
Power factor, displacement power factor, voltage unbalance, current unbalance, efficiency
12, Higher harmonics* (voltage/current): 2k~80kHz band
*Supraharmonics
13,Harmonics/phase angle (voltage/current), harmonic power: 0th ~ 50th
14,Harmonic voltage and current phase difference: 1st ~ 50th
15,Total harmonic distortion rate (voltage/current)
16, Interharmonics (voltage/current): 0.5th ~ 49.5th
17,K factor (multiplier)
18,V10 flicker, IEC flicker (short/long)
19. Mains signaling voltage |
| Maximum recording time |
Repeat function ON time: 1 year, maximum number of recorded events: 9999 x 366 days (maximum 9999 events in 1 day)
Repeat function OFF time: 35 days, maximum number of recording time: 9999 pieces |
| connector |
SD/SDHC card, LAN (HTTP server function/FTP total), USB2.0 (communication) |
| demonstrate |
6.5-inch TFT color LCD (640 x 480 dots) |
| power supply |
AC adapter Z1002 (100~240V, rated 1.7A, 50/60Hz) Battery pack Z1003 (180 minutes of continuous use, rechargeable by connecting to AC adapter, charging time 5 hours 30 minutes) |
| Volume and weight |
300W x 211H x 68D mm, 2.6 kg (with battery pack Z1003) |
| attachment (email) |
Instruction manual × 1, Measurement guide × 1, Crimp cable L1000 × 1 (red, yellow, blue, gray, black × 4, crocodile clips × 8), colorful test clips, AC adapter Z1002 × 1, Lanyard × 1, USB connecting cable (1m) × 1, Battery pack Z1003 × 1, SD memory card 2GB Z4001 × 1, Application software (PQ ONE) × 1 |