Power Analyzer PW8001
Power Analyzer PW8001
Power Analyzer PW8001
Power Analyzer PW8001
Power Analyzer PW8001
Power Analyzer PW8001
Power Analyzer PW8001
Power Analyzer PW8001

Power Analyzer PW8001

Great for improving power conversion efficiency
Correctly evaluating the power conversion efficiency of inverters and motors using GaN/SiC

Categories. , Tag. Brand.

Inquire about this product

High-level measurement accuracy for accurate evaluation of power conversion efficiency Basic accuracy, ±0.03%, DC accuracy ±0.05%, 50 kHz accuracy ±0.2%*1
-Accurately captures high-frequency power loss through excellent interference immunity and power spectrum analysis, with a sampling rate of 18 bit and interference immunity (CMRR) of 110dB/100kHz*1

-Data can be kept up to 1ms when measuring with the highest accuracy.

-Constructs a suitable measurement system with 2 input units.

-Synchronizes two hosts in real time via the optical port. Measurement of up to 16 ch, setup analysis for each ch*2

-Automatic compensation of phase characteristics of current sensors
-Simultaneous analysis of 4 motors (optional)
-Integration of measurement data into the CAN network (optional)
-Safety assessment of high voltage DC lines

DC 1500 V CAT II/ DC 1000 V CAT III*3

*1: When U7005 is used for the input unit

*2: BNC synchronization for data acquisition only

*3: When U7001 is used for the input unit

Basic parameters (accuracy guaranteed for 6 months, adjusted accuracy guaranteed for 6 months)

Measuring Lines Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Number of input units Maximum 8 units (units can be mixed and matched)
Input unit type U7001 2.5 MS/s Input Unit
U7005 15 MS/s Input Unit
Measurement frequency bandwidth U7001: DC, 0.1 Hz ~ 1 MHz
U7005: DC, 0.1 Hz ~ 5 MHz
Sampling Performance U7001: 2.5 MHz, 16bit
U7005: 15 MHz, 18bit
Data update rate 1 ms, 10 ms, 50 ms, 200 ms
Power accuracy (U7001) 50 Hz/60 Hz: 0.02% of reading + 0.05% of range
DC: 0.02% of reading + 0.05% of range
50 kHz : 0.4% of reading + 0.1% of range
Power accuracy (U7005) 50 Hz/60 Hz : 0.01% of reading + 0.02% of range
DC : 0.02% + 0.03% of reading of range
50 kHz: 0.15% of reading + 0.05% of range
measuring range Voltage: 6 V/ 15 V/ 30 V/ 60 V/ 150 V/ 300 V/ 600 V/ 1500 V
Current: (Probe1) 100 mA~2 kA, (Probe2) 100 mA~50 kA
(Range configuration varies depending on the current sensor used, Probe2 refers to U7001 only)
Measurement items Voltage (U), Current (I), Active Power (P), Apparent Power (S), Reactive Power (Q), Power Factor (λ), Phase Angle (φ), Voltage Frequency (fU), Current Frequency (fI), Power (η), Losses, Voltage Ripple Factor (Urf), Current Ripple Factor (Irf), Current Accumulation (Ih), Power Product (WP), Voltage Peak (Upk), Current Peak (Ipk), Voltage Ripple (Upk), Current Peak (Ipk), Voltage Peak (Upk), Current Peak (Ipk), Current Peak (Ipk), Current Peak (Ipk), Current Peak (Upk), Current Peak (Ipk), Current Peak (Ipk) Upk, Current Peak (Ipk)
Harmonic measurement: Maximum number of analyses 500
Waveform recording: Recording capacity 5MWord × ((voltage/current) × up to 8 channels + motor waveform)
Motor analysis (option): voltage, torque, speed, frequency, slew rate, motor power
Power spectrum analysis, IEC harmonics, voltage variation/flicker measurements
IEC measurement mode Conforms to IEC 61000-4-7:2002 with no data omissions

Analyzing times: Harmonic times 0 times~200 times; Interharmonic times 0.5 times~200.5 times

Measurement accuracy: Within the synchronization frequency range set for each frequency, the voltage, current, power, and phase measurement accuracy of each unit is plus ±0.04% of range. For 10 kHz or more, add ±0.04% of range.

Flicker Measurement Conforms to IEC 61000-4-15 Ed2.0:2010 flicker mode Class F2

Measurement items: short-time flicker value (Pst), short-time flicker maximum value (PstMax), long-time flicker value (Plt), instantaneous flicker maximum value (PinstMax), instantaneous flicker minimum value (PinstMin), relative steady-state voltage change (dc), maximum relative voltage change (dmax), time for relative voltage change to exceed the threshold value (Tmax)

Measuring range: Pst, Plt 0.0001 P.U. to 6400 P.U. (Logarithmic division is 1400 parts)

Measurement accuracy: Pst: ±5% (Pst=0.2~5), dc, dmax: ±4% (when dmax=4%)

functionality Operational functions (efficiency/loss, user-defined, Δ-conversion, automatic phase compensation of current sensors)
connector USB flash drive, LAN, GP-IB, RS-232C, external control, optical port, BNC synchronization, CAN/CAN FD
power supply AC 100 V to 240 V, 50 Hz/60 Hz, 230 VA
Volume and weight Approx. 430 W × 221 H × 361 D mm, approx. 14 kg
attachment (email) Power cord ×1, Precautions for use ×1, Instruction manual ×1, GENNECT One (PC application software) CD ×1, D-sub 25-pin connector ×1 (only PW8001-02, -05, -12, -15)
Expand More