TH8305-600-30 Rackmount Programmable DC Electronic Load Module
TH8305-600-30 Rackmount Programmable DC Electronic Load Module
TH8305-600-30 Rackmount Programmable DC Electronic Load Module
TH8305-600-30 Rackmount Programmable DC Electronic Load Module

TH8305-600-30 Rackmount Programmable DC Electronic Load Module

TH8300/TH8310 series programmable DC electronic load adopts modular design, users can select different parameters according to their own needs for free combination of modules.

All modules can be individually set to run, can be master-slave operation, support for parallel operation between modules, the whole machine between the four on-line.

Categories. , Tags. , , , , Brand.

Inquire about this product

TH8300/TH8310 series programmable DC electronic load adopts modular design, users can select different parameters according to their own needs for free combination of modules.

All modules can be individually set to run, can be master-slave operation, support for parallel operation between modules, the whole machine between the four on-line.

The module is equipped with dual-core (MCU+DSP) automatic control hardware circuit architecture, which makes the system run super stable. Complete circuit protection function and intelligent fan system, the instrument itself and the measured object to implement comprehensive protection. Adopt high-speed, safe and reliable 16-bit sampling chip to ensure sampling accuracy and resolution.

 

TH8300 series programmable DC electronic loads include the following types of modules (TH8301-80-20, TH8301A-80-20 are dual-channel modules):

image.png

Functional Features

A. Load operating mode

Conventional mode (4 types)
CC Constant current mode An electronic load always draws a constant current, regardless of whether the voltage changes.                             image.png
CR Constant Resistance Mode An electronic load is equivalent to a constant resistance, and the load changes current linearly with voltage.                             1628823946108087-1
CV Constant Voltage Mode The electronic load controls the voltage output from the power supply by adjusting the pull current according to the set voltage value.                             1628823962238396-1
CP Constant power mode An electronic load is equivalent to a constant resistance, and the load changes current linearly with voltage.                             1628823979285171-1
Advanced modes (12)
DYN Dynamic Load Mode A dynamic test frequency of up to 50kHz can be used to test the dynamic characteristics of the power supply over a wide bandwidth, with two current levels that can be set, the duration of each of the two current levels, the rising slope, the falling slope, and the number of repetitions. This function can be used to test the instantaneous high current tolerance of D/D converters and batteries.                       1628823986733648-1
SWP Dynamic frequency sweep mode The electronic load provides a programmable dynamic frequency sweep to invert the frequency to find the worst case voltage of the object to be measured. Dynamic Frequency Sweep requires the setting of two current levels, start frequency, end frequency, step frequency, duration, rise slope, and fall slope. During operation, the electronic load will pull current at the set frequency for the set duration. Frequencies up to 50kHz are used to capture the worst case Vp+, Vp- and corresponding Fp+, Fp- of the power supply under test.                      image.png
CR-LED Analog LED test pattern By setting the on-state voltage and resistance of the light-emitting diode, it can realistically simulate the actual load characteristics of the LED, avoiding the oscillations generated by the unstable voltage and current under the conventional constant resistance mode (CR), and thus detecting the real load conditions of the LED power supply.                       1628823998102549-1
BATT Battery Test Mode Load test battery performance, discharge conditions support CC, CR and CP three ways, by setting voltage, time, current capacity or power capacity of four conditions to let the electronic load to stop pulling load, to ensure that the battery will not be over-discharged and damaged.                              1628824002296618-1
TIME time measurement mode Measures the time from the start of the trigger condition to the end of the trigger condition in the range of 0s to 100000s. Can be used for battery charging and discharging tests and other similar applications.
MPPT Maximum power point tracking test mode Based on the DSP algorithm, find out the maximum power provided by the power supply and the corresponding voltage and current values.      1628824008569525-1
OCPT Overcurrent protection test mode The electronic load pulls a step-up current to test whether the output voltage of the power supply is lower than the trigger voltage under overload conditions, and then determine whether the output protection function of the power supply is normal.                              1628824012133196-1
OVPT Overvoltage protection test mode The load captures the peak and falling edge of the input voltage and triggers at the preset level (Vtrig) at the time of the falling edge, then this voltage peak is the overvoltage protection point of the power supply under test, and the time interval between the peak moment and the trigger moment is the OVP response time of the power supply under test (Tovp), and the accuracy of Tovp measurement is 2us.
OPPT Over Power Protection Test Mode The electronic load pulls the load step-up power to test whether the output voltage of the power supply is lower than the trigger voltage under overload conditions, and then determine whether the output protection function of the power supply is normal.  1628824021836537-1
SINE Sine wave test mode The electronic load has a unique sine wave pull current mode, which can be set to pull current deviation (I_DC), pull sine wave value (I_AC) and sine wave frequency value, the lowest point of this sine wave pull cannot be less than zero. The sine wave test can be used to simulate the ripple function.  

image.png

LIST List Test Mode The LIST mode can accurately complete complex arbitrary current change patterns at high speeds, accomplishing precision testing of multiple quasi-positional current carry loads. Multiple complex sequences are generated by editing the pull-load value, duration, slope, and repetition times for each step to meet complex testing needs.

It is mainly applied to simulate battery discharge pull current, laptop pull current, electric vehicle pull current, and dynamic current above two current levels.

    image.png
AUTO Automatic Test Mode The AUTO mode can accurately simulate the automatic test process of the production line and complete the multi-step precision test, which can help customers to save cost greatly. Different modes can be set for each step, and by editing the pull-load value, duration, rising slope, falling slope, and the upper and lower limits of current, voltage and power for each step, you can judge whether each step is qualified or not.

B.  short circuit function

Independent short-circuit test function supports short-circuit test in any function mode, realizing seamless connection with other functions. When the instrument enters the short-circuit test, the instrument is loaded at the maximum current of the current range.

C.   ALLRUNfunctionality

With the ALLRUN function, users can realize synchronous pulling or synchronous stopping of pulling current for different modules.

D.   Module inline function

Any number of modules can be linked for master-slave operation. The type of linkage is categorized into power mode and replication mode. Power mode is where the modules involved in the link are allocated to pull a proportional amount of current based on their maximum current. Duplicate mode is when all participating modules pull the current value set by the host module.

hosts TH8300 Frame TH8310 Frame
Number of Supported Modules 5 2
connector RS232, USB HOST, USB DEVICE, LAN, GPIB, SYSTEM I/O, CAN
stockpile 40 groups (50 state memories)
Operating power Supply Voltage 90-130VAC or 175-253VAC
frequency 47-63 Hz
power (output) ≤300VA
Temperature and environment operating temperature 0℃-40℃
Operating humidity 10%-90% (non-condensing)
storage temperature -20°C-70°C
altitude Operates up to 2000 meters above sea level
contamination level Pollution level 2
security level Safety Category II
Size and weight Frame Size 480mm×177mm×590mm
Frame weight 15kg
Module Model TH830180-20 TH8301A80-20 TH830280-40 TH830380-60 TH830480-80 TH830580-80 TH8302600-10 TH8303600-15 TH8305600-30
input power 100W×2 200W×2 200W×1 300W×1 400W×1 500W×1 200W×1 300W×1 500W×1
Input Voltage 0-80V 0-600V
Input Current 0-20A 0-20A 0-40A 0-60A 0-80A 0-80A 10A 0-15A 0-30A
Minimum operating voltage 0.5V@0.2A 0.5V@0.2A 0.5V@0.4A 0.5V@0.6A 0.4V@0.8A 0.4V@0.8A 2V@0.1A 2V@0.15A 2V@0.3A
0.5V@2A 0.5V@2A 0.5V@4A 0.5V@6A 0.4V@8A 0.4V@8A 2V@1A 2V@1.5A 2V@3A
0.5V@20A 0.5V@20A 0.5V@40A 0.5V@60A 0.4V@80A 0.4V@80A 2V@10A 2V@15A 2V@30A
Conventional mode Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
constant voltage

(CV)

range (of scales or measuring equipment) 6V 80V
resolution (of a photo) 0.1mV 1mV
range (of scales or measuring equipment) 16V 150V
resolution (of a photo) 1mV 10mV
range (of scales or measuring equipment) 80V 600V
resolution (of a photo) 1mV 10mV
accurate 0.05% + 0.1%FS
constant current

(CC)

range (of scales or measuring equipment) 0-0.2A 0-0.2A 0-0.4A 0-0.6A 0-0.8A 0-0.8A 0-0.1A 0-0.15A 0-0.3A
resolution (of a photo) 0.01mA 0.01mA 0.01mA 0.01mA 0.01mA 0.01mA 0.005mA 0.005mA 0.005mA
range (of scales or measuring equipment) 0-2A 0-2A 0-4A 0-6A 0-8A 0-8A 0-1A 0-1.5A 0-3A
resolution (of a photo) 0.1mA 0.1mA 0.1mA 0.1mA 0.1mA 0.1mA 0.05mA 0.05mA 0.05mA
range (of scales or measuring equipment) 0-20A 0-20A 0-40A 0-60A 0-80A 0-80A 0-10A 0-15A 0-30A
resolution (of a photo) 1mA 1mA 1mA 1mA 1mA 1mA 0.5mA 0.5mA 0.5mA
accurate 0.2% + 0.2%FS
constant resistance

(CR)

range (of scales or measuring equipment) 0.04-80Ω

(100W/6V)

0.04-80Ω

(100W/6V)

0.02-40Ω

(200W/6V)

0.015-30Ω

(300W/6V)

0.01-20Ω

(400W/6V)

0.01-20Ω

(400W/6V)

0.2-400Ω

(200W/80V)

0.133-270Ω

(300W/80V)

0.133-270Ω

(500W/80V)

range (of scales or measuring equipment) 1.44-2.9kΩ

(100W/16V)

1.44-2.9kΩ

(100W/16V)

0.8-1.5kΩ

(200W/16V)

0.3-600Ω

(300W/16V)

0.36-720Ω

(400W/16V)

0.36-720Ω

(400W/16V)

3-6kΩ

(200W/150V)

1.92-4kΩ

(300W/150V)

1.92-4kΩ

(500W/150V)

range (of scales or measuring equipment) 5.76-12kΩ

(100W/80V)

5.76-12kΩ

(100W/80V)

3-6kΩ

(200W/80V)

1.5-3kΩ

(300W/80V)

1.45-2.9kΩ

(400W/80V)

1.45-2.9kΩ

(400W/80V)

300-300kΩ

(200W/600V)

208-200kΩ

(300W/600V)

208-200kΩ

(500W/600V)

resolution (of a photo) 0.1Ω
accurate 1%
constant power

(CP)

range (of scales or measuring equipment) 0-2W 0-4W 0-4W 0-6W 0-8W 0-10W 0-4W 0-6W 0-10W
resolution (of a photo) 1mW 2mW 2mW 3mW 4mW 5mW 2mW 3mW 5mW
range (of scales or measuring equipment) 0-10w 0-20w 0-20w 0-30w 0-40w 0-50w 0-20W 0-30w 0-50w
resolution (of a photo) 10mW 20mW 20mW 30mW 40mW 50mW 20mW 30mW 50mW
range (of scales or measuring equipment) 0-100w 0-200w 0-200w 0-300w 0-400w 0-500w 0-200W 0-300w 0-500w
resolution (of a photo) 100mW 200mW 200mW 300mW 400mW 500mW 200mW 300mW 500mW
accurate 1%
Advanced Mode Dynamic Load Mode, Dynamic Frequency Scan, Analog LED Test, Battery Test, Time Measurement, Maximum Power Point Tracking Test, OCPT Test, OVPT Test,

OPPT test, sine wave test, list test, auto test.

Dynamic mode - constant current mode
Minimum Operating Voltage                                                        1.5V                                                                                    3V
frequency realm 100Hz-50kHz/0.01Hz-1kHz
accurate 1μs/1ms+100ppm
duty cycle 1-99% (controlled minimum rise time)
slope range (of scales or measuring equipment) 0.04A/ms-

0.02A/µs

0.04A/ms-

0.02A/µs

0.08A/ms-

0.04A/µs

0.12A/ms-

0.06A/µs

0.16A/ms-

0.08A/µs

0.16A/ms-

0.08A/µs

0.02A/ms-

0.01A/µs

0.03A/ms0.015A/µs 0.06A/ms-

0.03A/µs

resolution (of a photo) 0.01mA/µs 0.005mA/µs
range (of scales or measuring equipment) 0. 4A/ms-

0. 2A/µs

0. 4A/ms-

0. 2A/µs

0. 8A/ms-

0. 4A/µs

1.2A/ms-

0.6A/µs

1.6A/ms-

0. 8A/µs

1.6A/ms-

0. 8A/µs

0. 2A/ms-

0. 1A/µs

0. 3A/ms0. 15A/µs 0. 6A/ms-

0. 3A/µs

resolution (of a photo) 0.1mA/µs 0.05mA/µs
range (of scales or measuring equipment) 4A/ms2A/µs 4A/ms2A/µs 8A/ms4A/µs 12A/ms6A/µs 16A/ms8A/µs 16A/ms8A/µs 2A/ms1A/µs 3A/ms-

1.5A/µs

6A/ms3A/µs
resolution (of a photo) 1mA/µs 0.5mA/µs
accurate 10%±20µs
Minimum Rise Time 10µs
Measurement (readback)
input voltage range (of scales or measuring equipment) 0-6V 0-80V
resolution (of a photo) 0. 2mV 1.5mV
accurate 0.025% + 0.01%FS
range (of scales or measuring equipment) 0-16V 0-150V
resolution (of a photo) 0.3mV 2.7mV
accurate 0.025% + 0.01%FS
range (of scales or measuring equipment) 0-80V 0-600V
resolution (of a photo) 1.4mV 10.7mV
accurate 0.01% + 0.025%FS
amps range (of scales or measuring equipment) 0-0.2A 0-0.2A 0-0.4A 0-0.6A 0-0.8A 0-0.8A 0-0.1A 0-0.15A 0-0.3A
resolution (of a photo) 0.004mA 0.004mA 0.008mA 0.012mA 0.016mA 0.016mA 0.002mA 0.003mA 0.003mA
range (of scales or measuring equipment) 0-2A 0-2A 0-4A 0-6A 0-8A 0-8A 0-1A 0-1.5A 0-3A
resolution (of a photo) 0.04mA 0.04mA 0.08mA 0.12mA 0.16mA 0.16mA 0.02mA 0.03mA 0.03mA
range (of scales or measuring equipment) 0-20A 0-20A 0-40A 0-60A 0-80A 0-80A 0-10A 0-15A 0-30A
resolution (of a photo) 0.4mA 0.4mA 0.8mA 1.2mA 1.6mA 1.6mA 0.2mA 0.3mA 0.3mA
accurate 0.2% + 0.2%FS
power (output) range (of scales or measuring equipment) 0-16W 0-30W 0-30W 0-30W 0-60W 0-60W 0-60W 0-90W 0-180W
0-30W 0-60W 0-60W 0-60W 0-60W 0-60W 0-200W 0-300W 0-500W
0-100W 0-200W 0-200W 0-300W 0-400W 0-500W 0-200W 0-300W 0-500W
accurate 0. 1%+0.1%FS
protective function
Over Power Protection (OPP)
Overcurrent protection (OCP)
Overvoltage protection (OVP)
Over Temperature Protection (OTP)
short circuit function
Constant Current (CC) Set to 100% of rated current
Constant voltage (CV) 0V
Constant Resistance (CV) 60kΩ(6V) 150kΩ(16V) 700kΩ(80V)
Environment and temperature
operating temperature                                                                                                0-40°C
Size and weight
Dimension(mm) 142 x 85 x 550
Weight (kg) 4.2

■ TH8300 Series Programmable DC Electronic Load Performance Characteristics

■ The maximum power of the whole machine 2500W, the maximum current of 400A online

■ Module maximum power 500W, maximum current 80A, maximum voltage 600V.

■ 0.1mV/10μA high resolution

■ Dynamic frequencies up to 50 kHz

■ Up to 500kHz sampling rate

■ 12 advanced test functions

■ Modular design, supporting each module to operate separately

■ 40 files stored in a single module setup

■ A single machine supports up to five modules in parallel, supporting up to ten channels

■ Connections via CAN interfaces, supporting up to four machines on-line

■ 24-bit color 2.8-inch color LCD display

■ Chinese and English operation interface

■ Data logging function

■ Intelligent Fan Systems

■ Support for power-on hold function

■ Support for timer function

■ Electrical isolation, external inputs and outputs

■ Supports over-current protection (OCP), over-voltage protection (OVP), over-power protection (OPP), over-temperature protection (OTP), reverse polarity protection (REV), and low voltage protection (LVP).

■ Power supply

Charger, switching power supply, communication power supply, LED driver, cell phone battery, rechargeable treasure, etc.

▪ New energy

Solar Cells, New Power Vehicles, Electric Bicycles

■ Electronic power components

Fuses / Connectors / Relays / Sensors

■ Automated equipment integration testing

standard equipment
Accessory Name model number

 

optional
Accessory Name model number
High Current Test Cables TH26035D
High Current Test Cables TH26035E
26 pole analog control interface (TH6700) TH26081
Expand More
TH8305-600-30 Rackmount Programmable DC Electronic Load ModuleTH8305-600-30 Rackmount Programmable DC Electronic Load Module

Click to enquire

Product consultation and purchase:18218718851

I already understand