TH6732 Programmable Switching DC Power Supply
TH6732 Programmable Switching DC Power Supply
TH6732 Programmable Switching DC Power Supply
TH6732 Programmable Switching DC Power Supply
TH6732 Programmable Switching DC Power Supply
TH6732 Programmable Switching DC Power Supply

TH6732 Programmable Switching DC Power Supply

The TH6700 series is a single output, wide-range programmable switching DC power supply available in 360W, 720W and 1080W outputs. Users can realize master-slave series connection of 2 units or master-slave parallel connection of 3 units of TH6700 power supply to meet higher output voltage and output current requirements.

Categories. , Tags. , , Brand.

Inquire about this product

The TH6700 series is a single output, wide-range programmable switching DC power supply available in 360W, 720W and 1080W outputs. Users can realize master-slave series connection of 2 units or master-slave parallel connection of 3 units of TH6700 power supply to meet higher output voltage and output current requirements.

The TH6700 series has an adjustable slope function, which allows the user to set the rise and fall time of the output voltage and current to avoid damaging the device by the surge current during the switching moment.

The constant voltage/constant current prioritization mode of TH6700 series can well protect the measured parts. Conventional power supplies are usually in CV mode when the output is turned on, which will instantly bring large inrush current to capacitive loads. TH6700 series can be prioritized to run in CC mode when the output is turned on, avoiding the sudden spike current and protecting the device.

The programmable internal resistance function of the TH6700 series can be applied to simulate the output of a battery. For example, the TH6700 can set the resistor value that simulates the internal resistance of the battery so that the output voltage drops.

The TH6700 series provides OVP, OCP and OTP protection. Once the output voltage or current exceeds the pre-set value, the output will shut down immediately; once the temperature inside the machine exceeds a certain temperature, the output will also shut down immediately.

The rear panel of TH6700 series can be connected to two-end measurement or four-end measurement. When connected as a four-terminal measurement, it has a remote compensation function, which can compensate for the voltage drop from the power supply to the device to be measured.

Functional Features

A. Adjustable slope function

Control the output by setting the voltage or current rise/fall time to obtain the voltage/current conversion rate

For example, if you set the output voltage to 20V and the voltage conversion rate to 5V/s, the rise time is 4s;

A voltage conversion rate of 10V/s results in a rise time of 2s;

A voltage conversion rate of 20V/s results in a rise time of 1s;

A voltage conversion rate of 40V/s results in a rise time of 0.5s.

1599448647123686-1

B. Programmable Internal Resistors - Emulates Battery Outputs

Batteries generally have internal resistors, and when powered by batteries, the output voltage drops due to voltage dividing by the battery's internal resistors.

Calculation formula:

1599448787105819-7

1599448892126225-11599448936103586-9

Use the TH6700 to set the analog internal resistance value so that the output voltage falls, simulating the true output of the battery.

C. Data Retention - Recording of DUT operational data

Used to record data such as current, voltage, time, etc., start recording at a rate of 1 time/s after turning on the recording, maximum 5000 times.

Connect the sense terminal to record the actual voltage and current values at both ends of the measured part;

Without connecting the sense terminal the voltage and current values of the TH6700 output are recorded.

When finished, the instrument data will be saved with a CSV extension to the CSV folder on the USB flash drive.

1599456048235685-1

D. Constant Voltage (CV)/Constant Current (CC) Priority Selection Mode - Protects DUTs

Conventional power supplies are usually in CV mode when the output is turned on, which can instantly introduce a large inrush current to capacitive loads.

Constant Voltage Priority Mode for obtaining a faster rate of voltage creep when the output is turned on in order to target test scenarios that require high voltage speeds.

Constant Current Priority Mode means that at the moment the output is turned on, it operates preferentially in CC mode and can.

1. Avoids sudden spikes in current and protects the device from damage by inrush current.

2. Output current without overshoot, used to test the constant current operating characteristics of the object to be tested

1599456165437073-2

1599456209583424-2

1599456250117605-2

parameters TH6731 TH6732 TH6733 TH6741 TH6742 TH6743
exports power (output) rating 360W 720W 1080W 360W 720W 1080W
power limit Approximate power rating*105%
input voltage rated voltage 0-250V 0-800V
Maximum voltage 262.5V 840V
amps rated current 4.2A 8.4A 12.6A 1.32A 2.64A 3.96A
Maximum current 4.5A 9A 13.5A 1.44A 2.88A 4.32A
found

install

input voltage realm 0-262.5V 0~840V
amps realm 0-4.5A 0-9A 0-13.5A 0-1.44A 0-2.884A 0-4.32A
Load regulation rate*1 input voltage ≤130mV ≤405mV
amps ≤9.5mA ≤14mA ≤18.5mA ≤6.44mA ≤7.88mA ≤9.32mA
Power conditioning rate*2 input voltage ≤128mV ≤403mV
amps ≤9.5mA ≤14mA ≤18.5mA ≤6.44mA ≤7.88mA ≤9.32mA
Setting value resolution input voltage 100mV
amps 1mA 1mA 10mA 1mA 1mA 1mA
Readback resolution input voltage 100mV
amps 1mA 1mA 10mA 1mA 1mA 1mA
Setpoint accuracy

(25°C±5°C)

Voltage (>0.1V) ≤0.1%+200mV ≤0.1%+400mV
Current (>0.1A) ≤0.1%+5mA ≤0.1%+10mA ≤0.1%+20mA ≤0.1%+2mA ≤0.1%+4mA ≤0.1%+6mA
Readback accuracy

(25°C±5°C)

Voltage (>0.1V) ≤0.1%+200mV ≤0.1%+400mV
Current (>0.1A) ≤0.1%+5mA ≤0.1%+10mA ≤0.1%+20mA ≤0.1%+2mA ≤0.1%+4mA ≤0.1%+6mA
Ripple and Noise

(20Hz-2MHz)

differential mode voltage ≤80mVp-p and 15mVrms ≤100mVp-p and 15mVrms ≤120mVp-p and 15mVrms ≤150mVp-p and 30mVrms ≤200mVp-p and 30mVrms ≤200mVp-p and 30mVrms
Differential mode current ≤10mArms ≤20mArms ≤30mArms ≤5mArms ≤10mArms ≤15mArms
Dynamic recovery time*3

(50%-100% loads) Load frequency = 100Hz

≤2ms
Rise time*4 (unloaded) 10%-90% ≤100ms ≤150ms
Rise time*4 (full load) 10%-90% ≤100ms ≤150ms
Descent time*5 (full load) 90%-10% ≤150ms ≤300ms
Descent time*5 (unloaded) 90%-10% ≤1200ms ≤2000ms
timers Setting range 0-9999999 (hours, minutes and seconds)
start-up delay Setting range 0-99.99s
stop delay Setting range 0-99.99s
Slope Setting Voltage rise 0.1~500V/s 1~1600V/s
voltage drop 0.1~500V/s 1~1600V/s
Current Rise 0.001~9A/s 0.01~18A/s 0.01~27A/s 0.001~2.88A/s 0.001~5.76A/s 0.001~8.64A/s
Current drop 0.001~9A/s 0.01~18A/s 0.01~27A/s 0.001~2.88A/s 0.001~5.76A/s 0.001~8.64A/s
analog internal resistance Setting range 0~55.55Ω 0~27.77Ω 0~18.51Ω 0~555.5Ω 0~277.8Ω 0~185.1Ω
External Voltage Control

(25°C±5°C)

CV accuracy Rated output voltage ±0.5%
CC Accuracy Rated output current ±1%
External Resistance Control

(25°C±5°C)

CV Accuracy Rated output voltage ±1.5%
CC Accuracy Rated output current ±1.5%
power factor 100VAC (full load) 0.99 0.99
200VAC (full load) 0.97 0.97
efficiencies 100VAC (full load) 77% 78%
200VAC (full load) 79% 80%
master-slave control master-slave parallel connection Includes up to 3 mainframes in parallel
master-slave tandem not have
safeguard Overvoltage OVP 20-275V 20-880V
OVP Accuracy Rated Output Voltage of ±2%
Overcurrent OCP 0.45~4.72A 0.9~9.45A 1.35~14.17A 0.144-1.512A 0.288-3.024A 0.432-4.536A
OCP Accuracy Rated Output Current of ±2%
Over Temperature OTP Internal Temperature Rise Decision
Volume and weight Outline volume (mm) 215(W)×146(H)×420(D)
Upper shelf volume (mm) 215(W)×132(H)×420(D)
Weight (net) 3kg 5.3kg 7.5kg 3kg 5.3kg 7.5kg
Power supply 88-265VAC, 50/60Hz
Notes:

*1. Load regulation rate (no load - full load, constant input voltage)

*2. Power supply regulation rate (88-132 VAC or 170-265 VAC, constant load)

*3. dynamic recovery time (the time for the output voltage to recover within 0.1%+10mV of the rated output when the load varies from 50% to 100% of the rated output current.

(Load frequency = 100Hz)

*4. Rise time (rated output voltage 10%-90% with rated resistive load)

*5. Fall-off time (rated output voltage 90%-10% with rated resistive load)

■ Rated output: 0-250V/0-8.4A (720W)

■ Wide-range operation, constant power output

■ High efficiency and high power density

■ Programmable internal resistor to emulate battery outputs

■ Constant current priority mode to reduce voltage and current overshoot when powering LEDs

■ Master-slave serial-parallel operation

■ 24-bit color 4.3-inch color LCD display

■ Numeric keypad operation

■ Knobs for coarse and fine adjustment of voltage and current values

■ Timing output time (0-3600.0s)

■ Rise time of programmable voltage or current

■ RS232, USB HOST, USB DEVICE, LAN, analog control interface

▪ Generic testing for R&D and design verification

▪ New energy Solar cells, new power vehicles, electric bicycles

▪ Routine testing and maintenance of production line benches

■ Automated equipment integration testing

▪ Solar photovoltaic simulation testing

▪ Teaching laboratories

■ LED testing

Expand More