Product Overview: Fluke 1503 Insulation Resistance Tester
The Fluke 1503 Insulation Testers are compact, rugged and very easy to operate. With the ability to accept a wide range of test voltages, they are the ideal tool for many overhaul, commissioning and preventive maintenance situations.
These tools are also equipped with other components such as remote probes, which makes the testing process very fast and cost effective.
Product Specification: Fluke 1503 Insulation Resistance Tester
| AC/DC voltage measurement | |||||
| accurate | range (of scales or measuring equipment) | 600.0 V | |||
| resolution (of a photo) | 0.1 V | ||||
| 50 Hz to 400 Hz ± (% + bits of reading) | ± (2% + 3) | ||||
| Input Impedance | 3 MΩ (nominal), < 100 pF | ||||
| Common mode attenuation rate (1 kΩ unbalanced) | > 60 dB at DC, 50 or 60 Hz | ||||
| overload protection | 600 V rms or DC | ||||
| Measurement of earth connection resistance | |||||
| Range/Resolution | 20.00 Ω | 0.01 Ω | |||
| 200.0 Ω | 0.1 Ω | ||||
| 2000 Ω | 1.0 Ω | ||||
| 20.00 kΩ | 0.01 kΩ | ||||
| accurate | ±(1.5% + 3) | ||||
| overload protection | 2 V rms or DC | ||||
| Open Circuit Test Voltage | > 4.0 V, < 8 V | ||||
| short-circuit current | > 200.0 mA | ||||
| Insulation specifications | |||||
| Measured value range | 0.01 MΩ to 2000 MΩ | ||||
| test voltage | 500 V, 1000 V | ||||
| Test Voltage Accuracy | + 20%, - 0% | ||||
| short-circuit current | 1 mA (nominal) | ||||
| Automatic discharge | Discharge time < 0.5 sec, C = 1 µF or less | ||||
| Live Circuit Indicator | Inhibit test if termination voltage > 30 V before initialization test | ||||
| Maximum capacitive load | Operable with loads below 1 µF | ||||
| Measurement accuracy | |||||
| output voltage | Display range | resolution (of a photo) | Test Current | accuracy ± (% reading + lowest significant bit amount) |
|
| 500 V (0 % to + 20 %) | 0.1 to 20.0 MΩ | 0.01 MΩ | 1 mA @ 500 kΩ |
± (2.0 % + 5) | |
| 20.0 to 200.0 MΩ | 0.1 MΩ | ||||
| 200 to 500 MΩ | 1 MΩ | ||||
| 1000 V (0 % to + 20 %) | 0.1 to 200.0 MΩ | 0.1 MΩ | 1 mA @ 1 MΩ |
± (2.0 % + 5) | |
| 200 to 2000 MΩ | 1 MΩ | ||||
| General technical indicators | |||||
| Maximum voltage applied to any terminal: | 600 V AC rms or DC | ||||
| storage temperature | -40 °C to 60 °C (-40 °F to 140 °F) | ||||
| operating temperature | -20 °C to 55 °C (-4 °F to 131 °F) | ||||
| temperature coefficient | 0.05 x (specified accuracy)/°C at temperatures 28 °C ( 82 °F) | ||||
| relative humidity | |||||
| 0% to 95% at 10 °C to 30 °C (50 °F to 86 °F) | |||||
| 0% to 75% at 30 °C to 40 °C (86 °F to 104 °F) | |||||
| 0% to 40% at 40 °C to 55 °C (104 °F to 131 °F) | |||||
| vibratory | Random, 2 g, 5-500 Hz, according to MIL-PRF-28800F Class 2 Instruments | ||||
| impingement | 1 m drop according to IEC 61010-1 2nd edition (1 m drop test, six sides, oak floor) | ||||
| electromagnetic compatibility | Accuracy = specified accuracy in an RF magnetic field of 3 V/M (EN 61326-1:1997) | ||||
| safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd edition, Class IV measurement 600 V (CAT IV). | ||||
| accreditation | CSA according to standard CSA/CAN C22.2 No. 61010.1-04; TUV according to standard IEC/EN 61010-1 2nd edition. | ||||
| batteries | Four AA batteries (NEDA 15A or IEC LR6) | ||||
| Battery life | Insulation testing purposes: | At room temperature, the new alkaline batteries will allow the meter to perform at least 1000 insulation tests. These standard results are measured with 1000 V passed through a 1 MΩ resistor, with an operating cycle of 5 seconds on and 25 seconds off. | |||
| Resistance measurements: | The new alkaline batteries allow the meter to make at least 2500 ground connection insulation measurements at room temperature. These standard results are measured at 1 Ω resistance with a 5 second on, 25 second off duty cycle. | ||||
| Dimensions (H x W x D) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) | ||||
| weights | 550 g (1.2 lb) | ||||
| IP Protection Rating | IP40 | ||||
| height above sea level | Working altitude | 2000 m CAT IV 600 V, 3000 m CAT III 600 V | |||
| Non-operational (storage) | 12000 m | ||||
| overcapacity | 110% Range | ||||
| Includes accessories | TL224 Test Lead, TP74 Test Probe, Clip Part Numbers 1958654 (Red) and 1958646 (Black), Holster and Remote Probe | ||||
Model: Fluke 1503 Insulation Resistance Tester
FLUKE- 1503
Insulation multimeter
Includes.
- remote probe
- Test Leads
- Test Probes
- spring clip
- holster
- user manual