Chroma 19501-K partial discharge tester built-in AC withstand voltage test (Hipot Test) and partial discharge (Partial Discharge, PD) detection function in a single machine to provide AC voltage output 0.1kV ~ 10kV, leakage current measurement range of 0.01μ A ~ 300μA, partial discharge detection range of 1pC ~ 2000pC. 2000pC, designed and developed for high-voltage semiconductor components and high-insulation material testing applications.
Chroma 19501-K Partial Discharge Tester is designed to comply with IEC60270-1 regulations, for high voltage test technology for partial discharge test requirements, using Narrowband measurement technology for PD discharge measurement, and the measurement results will be visualized as a numerical value (pC) displayed on the screen so that users can clearly understand the test results of the object to be tested. The results are visualized on the screen so that the user can clearly understand the results of the test.
The product design not only complies with IEC60270-1, but also meets the requirements of IEC60747-5-5 and VDE0884 regulations for optocouplers. The built-in test method of IEC60747-5-5 is included in the instrument, which meets the needs of optocoupler production testing and provides users with a user-friendly operation interface.
When performing high voltage test on production line, if the object to be tested is not properly and well connected to the test line, it will lead to failure of the test result or even the risk of leakage, so it is very important to ensure that the object to be tested is well connected to the test line before the test. Chroma's unique High Voltage Contact Check (HVCC) function utilizes the Kelvin test method for components with high isolation capability to conduct contact check at the same time as the high voltage output, which increases the effectiveness of the test and production efficiency.
When solid insulators contain air gaps or impurities mixed in the insulating layer, under rated high voltage condition, partial discharge (Partial Discharge) occurs due to the high electric field strength concentrated in the air gaps, and the persistent partial discharge will deteriorate the surrounding insulating materials for a long time, which affects the long term trustworthiness of the electrical products, and causes safety accidents.
Applied to the power supply system safety components, such as optocouplers, due to the consideration that if the components occur for a long time partial discharge for the destruction of the insulation material, and the occurrence of insulation failure, which in turn led to the user's personal safety problems; therefore, in the IEC60747-5-5 regulations mentioned in the production process (Routine test) must be 100% execution of partial discharge ( Therefore, as mentioned in the IEC60747-5-5 regulation, during the production process (Routine test), 100% must be used for Partial Discharge (PD) detection, and the amount of PD must not be more than 5pC under the condition of the maximum insulating voltage, so as to ensure that PD will not occur in the normal working environment.
Partial discharge testers are mainly used for high voltage optocouplers, high voltage relays and high voltage switches and other components with high insulation resistance to provide high voltage withstand voltage testing and partial discharge detection to ensure product quality and improve product reliability.
| model number | relate (a story or information) |
| 19501-K | Partial Discharge Tester |
| A195001 | PD Corrector |
| B195000 | electromagnetic shield |
| B195001 | High Voltage Connection Adapter |
| B195002 | DIP Test Fixture |