Excellent user interface and user experience
- Equipped with a large 10.1-inch TFT-LCD display with 1024*600 resolution;
- The capacitive touch screen, with various gestures defined specifically for oscilloscope operation, greatly improves the efficiency of instrument control;
- Embedded WebServer allows remote access and operation of the oscilloscope directly through web pages;
- Supports mouse and keyboard operation
- The capacitive touch screen, with various gestures defined specifically for oscilloscope operation, greatly improves the efficiency of instrument control;
- Embedded WebServer allows remote access and operation of the oscilloscope directly through web pages;
- Supports mouse and keyboard operation

10-bit mode for better waveform detail reproduction
Vertical resolution is used to describe the number of bits of the ADC in a digital oscilloscope, i.e. the higher the number of bits, the higher the vertical resolution, the closer the displayed waveform is to the real waveform.
As shown in the figure, the waveforms in 8-bit mode and 10-bit mode are shown respectively.
As shown in the figure, the waveforms in 8-bit mode and 10-bit mode are shown respectively.


Convenient statistical functions for measuring parameters
Parameter statistics function can display five measurement values of any parameter: current value, average value, minimum value, maximum value, standard deviation; 12 different parameters can be measured and counted at the same time. Histogram statistics can intuitively show the probability distribution of parameters; trend graph can reflect the change rule of parameters over time.
In addition, for measurements in the horizontal direction (e.g., period, pulse width, etc.), the traditional method of obtaining only one measurement in a frame is discarded, and the measurements of all specified horizontal items in a frame are calculated and included in the statistics, which greatly improves test efficiency.
In addition, for measurements in the horizontal direction (e.g., period, pulse width, etc.), the traditional method of obtaining only one measurement in a frame is discarded, and the measurements of all specified horizontal items in a frame are calculated and included in the statistics, which greatly improves test efficiency.


Powerful Power Test Functions
- Baud diagram (standard): use the baud diagram to test the frequency response or loop stability of the system, replacing expensive network analyzers in certain areas. It can be matched with built-in waveform generator or external SDG series arbitrary waveform generator;
-Power analysis (optional): The power analysis option helps users to quickly measure and analyze several items in the power electronics field, such as power quality, harmonics, inrush current, switching loss, output ripple, transient response, power supply rejection ratio, power efficiency, and so on.
-Power analysis (optional): The power analysis option helps users to quickly measure and analyze several items in the power electronics field, such as power quality, harmonics, inrush current, switching loss, output ripple, transient response, power supply rejection ratio, power efficiency, and so on.


| model number | analog bandwidth | channel number | Maximum real-time sampling rate | Maximum waveform capture rate | Maximum storage depth | Reference price (including tax) |
|---|---|---|---|---|---|---|
| SDS2504X Plus | 500 MHz | 4 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥26,880 |
| SDS2502X Plus | 500 MHz | 2 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥22,980 |
| SDS2354X Plus | 350 MHz | 4 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥18,680 |
| SDS2352X Plus | 350 MHz | 2 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥15,280 |
| SDS2204X Plus | 200 MHz | 4 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥13,580 |
| SDS2202X Plus | 200 MHz | 2 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥9,980 |
| SDS2104X Plus | 100 MHz | 4 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥11,480 |
| SDS2102X Plus | 100 MHz | 2 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | ¥9,080 |
| SDS2074X Plus | 70 MHz | 4 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | E-commerce Specialty Series |
| SDS2072X Plus | 70 MHz | 2 + EXT | 2 GSa/s | 500,000 wfm/s | 200 Mpts/ch | E-commerce Specialty Series |
| Specification | |||
|---|---|---|---|
| bandwidths | 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz | 16 digital channels (standard) | 500 MSa/s sample rate, 50 Mpts/channel memory depth |
| real time sampling rate | 2 GSa/s | mathematical operation | 2-way: 2M point FFT, addition, subtraction, multiplication, division, integration, differentiation, square root, averaging, ERES and custom expressions |
| channel number | 2/4 + EXT | automatic measurement | Dozens of automatic measurement functions, support measurement statistics, Gating measurement, Math measurement, History measurement, Ref measurement. Support histogram and trend statistics of measured parameters. |
| Storage depth | 200 Mpts/CH | connector | USB 2.0 Host x2, USB 2.0 Device, LAN, External Trigger Input, Auxiliary Output (TRIG OUT, PASS/FAIL) |
| Maximum waveform capture rate | 500,000 wfm/s (Sequence mode) | screen (TV, computer or movie) | 10.1-inch capacitive touchscreen display with 1024*600 resolution |
| vertical resolution | 8 bit, 10-bit mode optional | Maximum Input Voltage | 1 MΩ ≤ 400 Vpk(DC + AC), DC~10 kHz |
| Input Impedance | (1 MΩ±2%) || (17 pF±2 pF) | 50 Ω ≤ 5 Vrms, ±10 V Peak | |
| 50 Ω: 50 Ω±1% | sizes | W×H×T = 352 mm×224 mm×111 mm | |
| Time base range | 1.0 ns/div ~ 1000 s/div | weights | 2-channel net weight 3.3 kg, gross weight 4.8 kg |
| ROLL: ≥ 50 ms/div | 4-channel net weight 3.9 kg, gross weight 5.4 kg | ||
| Trigger Type | Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video | ||
| Serial data decoding type | Standard: IIC, SPI, UART, CAN, LIN | ||
| Options: CAN FD, FlexRay, IIS, MIL-STD-1553B, SENT, Manchester | |||
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.