DC High Voltage Test Probe P2000
DC High Voltage Test Probe P2000
DC High Voltage Test Probe P2000
DC High Voltage Test Probe P2000
DC High Voltage Test Probe P2000
DC High Voltage Test Probe P2000

DC High Voltage Test Probe P2000

-Safely detects high-voltage photovoltaic equipment -Supports CAT III 2000V high voltage testing
Safety testing of high-voltage photovoltaic power plants

Categories. , Tag. Brand.

Inquire about this product

● Realization of high voltage measurements up to CAT III 2000V
:: Safe measurement of megawatt-scale photovoltaic power plants without interrupting the grid
● Can be used with a corresponding HIOKI clamp meter or digital multimeter (DMM).

Basic parameters (accuracy guaranteed for 1 year)

Maximum Input Voltage (*1)) DC 2000 V
*1: Between INPUT H - INPUT L, maximum input voltage
Maximum input voltage to ground 2000 V (Measurement Scope III) Estimated transient overvoltage 15000 V
1000 V (Measurement Scope III) Estimated transient overvoltage 12000 V
Input Impedance 20 MΩ ±1.0% (between INPUT H - INPUT L)
overload protection DC 2200 V/AC 2200 V 1 minute (between INPUT H and INPUTOL)
DC 600 V/AC 600 V 1 minute (between OUTPUT H and OUTPUT L)
output terminal 4 mm banana head
Location Indoor use, pollution level 2, within 2000 m altitude
Operating temperature and humidity range Temperature: -25℃~65℃
Humidity: -25°C to 40°C, 80% RH or less (no condensation)
40℃~65℃, 40℃, 80% RH ~65℃, 25%
Linear reduction of the upper limit of humidity for use up to RH (no condensation)
Storage temperature and humidity range -30°C to 70°C , 90% RH or less (no condensation)
Applicable standards EN 61010
attachment (email) L4943 Connection Cable, Hitch Strap, C2025 Carrying Case, Instruction Manual, Notes on Use

Combined accuracy with clamp meter and multimeter

model number Combined accuracy parameters
DT4261 Range 600.0 V, ±0.5% rdg ±0.2 V
Range 2000 V, ±0.5% rdg ±5 V
CM4375-50 Range 600.0 V, ±1.0% rdg ±0.3 V
Range 2000 V, ±1.0% rdg ±3 V
CM4373-50
CM4371-50
CM4141-50
DT4281 Range 60.000 V, ±0.8% rdg ±0.002 V (output ratio 1/10)
Range 600.00 V, ±0.8% rdg ±0.02 V (1/10 output ratio)
DT4282
DT4252 Range 60.00 V, ±1.2% rdg ±0.05 V (1/10 output ratio)
Range 600.0 V, ±1.2% rdg ±0.5 V (1/10 output ratio)
DT4253
DT4255 Range 60.0 V, ±1.2% rdg ±0.03 V (1/10 output ratio)
DT4256 Range 600.0 V, ±1.2% rdg ±0.3 V (1/10 output ratio)
Expand More
DC High Voltage Test Probe P2000DC High Voltage Test Probe P2000

Click to enquire

Product consultation and purchase:18218718851

I already understand