AC Leakage Current Clamp Meter CM4003 (with output and external power supply function)
AC Leakage Current Clamp Meter CM4003 (with output and external power supply function)
AC Leakage Current Clamp Meter CM4003 (with output and external power supply function)
AC Leakage Current Clamp Meter CM4003 (with output and external power supply function)

AC Leakage Current Clamp Meter CM4003 (with output and external power supply function)

Intelligent leakage detection, higher precision measurement!

Categories. , Tag. Brand.

Inquire about this product

● Corresponds to wireless! Data transmission with smartphones and tablet devices is possible (with optional wireless adapter Z3210).
● Measured values are transmitted wirelessly and directly into Excel® sheets (with optional wireless adapter Z3210).
:: Newly designed sensors can correctly check leakage current (up to φ40 mm diameter).
● Measurement from leakage current to load current.
● Conforms to the performance criteria specified in the international leakage current clamp standard IEC / EN 61557-13.
:: Responding to leakage faults -- insulation management
● Functions to shorten pass/fail determination time
● Output function (waveform/RMS) to combine with a recorder, record waveforms and variations
Use of an AC adapter with external power supply function (optional) enables continuous measurement over long periods of time.

 

CAT III 300 V

Basic parameters (accuracy guaranteed for 1 year, adjusted accuracy guaranteed for 1 year)

AC current range 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, true RMS rectified
Basic Accuracy 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA ~ 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
Basic accuracy 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt
Accuracy specification range 0.060 mA to 200.0 A
AC Voltage Range not have
frequency range 15.0 Hz to 2000 Hz
crest factor 3 (outside 200.0 A range), 1.5 (200.0 A range)
filtration function Cutoff frequency at ON 180 Hz ±30 Hz (-3 dB)
output function RMS (True RMS Output), WAVE (Waveform Output)
harmonic (wave with frequency an integer multiple of the fundamental) Harmonic level/content/total harmonic distortion up to the 30th order in the current can be measured [when Z3210 is installed].
* :: Can be displayed using application software (GENNECT Cross)
Other Functions Maximum / Minimum / Average / Peak Maximum / Peak Minimum display, Display value Hold, Auto Hold, Background light, Auto power saving function, Beeper, Number of events display, Comparator, Simple event log, Inrush current test
demonstrate Display update rate: 5 times/second
power supply Alkaline Battery No. 5 (LR6) × 2, Continuous use time: 48 h (without Z3210), 30 h (wireless communication when used with Z3210)
AC Adapter Z1013 (DC 5 V, 2.6 A)
Measurable conductor diameter φ40 mm or less
Dimensions/Weight 64W × 233H × 37D mm, 400 g
attachment (email) Cable L9097 ×1, USB cable ×1, Carrying case C0203 ×1, Instruction manual ×1, Precautions for use ×1, Alkaline battery No. 5 (LR6) ×2