Clamp-on current probe 3276
Clamp-on current probe 3276
Clamp-on current probe 3276
Clamp-on current probe 3276
Clamp-on current probe 3276
Clamp-on current probe 3276
Clamp-on current probe 3276
Clamp-on current probe 3276

Clamp-on current probe 3276

DC to 100MHz wideband current probe with direct input to oscilloscope (50A peak (discontinuous))
Maximum value 30A 0.1V/A output Jaw diameter 5mm

Categories. , Tag. Brand.

Inquire about this product

:: Frequency bandwidth: DC to 100 MHz
:: High S/N ratio: waveform observation possible at the mA level
● Direct input to the oscilloscope's BNC terminal
● Waveforms can be observed in the memory recorder.
● Using the optional dedicated power supply, it is possible to provide a power supply other than that of the oscilloscope.

※Please use it on the main unit of a measuring instrument with a high input impedance of 1 MΩ or more.

Basic parameters

bandwidth DC ~ 100MHz(-3dB)
rising time ≤3.5ns
Continuous maximum input range 30A rms
Maximum peak current 50A peak (discontinuous)
Output Voltage Rate 0.1V/A
Amplitude accuracy ±1.0%rdg.±1mV (0 to 30A) (DC, 45 to 66Hz, maximum continuous input range)
static (in a signal) 2.5mA max or less (bandwidth limited to 20MHz)
Temperature Characterization Sensitivity ±2% (0 to 40°C)
Rated Maximum 5.3VA
power supply (of an appliance etc) ±12V ±0.5V
operating environment 0~40℃, max. 80%rh (non-condensing)
External magnetic field impedance 0.5mA max (equivalent) (DC and 60Hz, magnetic field 400A/m)
Maximum line voltage 300V CAT-I (insulator)
Wire under test Diameter up to 5mm
Volume and weight Sensor approx. 175 W x 18 H x 40 Thick mm, 240g
Terminal unit approx. 27 W x 55 H x 18 Thickness mm
cable length Sensor cable: approx. 1.5m (BNC connection)
Power cable: approx. 1m
attachment (email) Soft case × 1, instruction manual × 1

Power supply 3272 (parameters)

Applicable Sensor Models Clamp-on current probe 3273-50, 3274, 3275, 3276 × 1 (max.)
※Current probe 3273 × 2 (max.), for smaller test current values, 2 of 3273-50/3274/3275/3276 can be used at the same time.
power supply AC100V ±10%, 50/60Hz, 20 VA max, (to be specified for 120, 220, 240 V)
Volume and weight 73W × 110H × 186 D mm,1.1kg
attachment (email) Power Cord × 1, Instruction Manual × 1, Spare Fuse × 1

Power supply 3269 (parameter)

Applicable Sensor Models Clamp-on current probes 3273-50, 3274, 3275, 3276 × 4 (max.)
※Current probe 3273 × 4 (max.)
power supply AC 100 to 240V, 50/60Hz, 170 VA max.
Volume and weight 80W × 119H × 200Dmm, 1.1kg
attachment (email) Power cord × 1, Instruction manual × 1

Continuous Maximum Input Range (Frequency Delay)

Expand More
Clamp-on current probe 3276Clamp-on current probe 3276

Click to enquire

Product consultation and purchase:18218718851

I already understand