High Resistance Meter SM7120
High Resistance Meter SM7120
High Resistance Meter SM7120
High Resistance Meter SM7120
High Resistance Meter SM7120
High Resistance Meter SM7120
High Resistance Meter SM7120
High Resistance Meter SM7120

High Resistance Meter SM7120

High resistance meter that can be used in a variety of ways, up to 2000V, as fast as 6.4ms.
High-speed measurement up to 6.4ms Output voltage 2000V Resistance 2×10^19Ω Maximum display Current 0.1fA resolution

Categories. , Tag. Brand.

Inquire about this product

:: Achieved 300 times the interference immunity of conventional products.
● High-speed measurement of up to 6.4ms
:: Low capacitance check as a Picoammeter
● Maximum 2 x 10^19 Ω display, minimum 0.1 fA resolution
● EXT I/O, RS-232C, GP-IB, USB are standard.
:: Electrostatic meter, picoammeter, IR meter, which can be arranged freely

The main unit does not come with a test probe, please purchase the optional probe according to the measurement application.
For use with existing electrodes the optional conversion adapter Z5010 must be purchased.

Basic parameters (1 year accuracy guarantee time, 1 year accuracy guarantee time after adjustment)

Number of measurement channels 1ch
DC current measurement (accuracy) 20 pA range (resolution 0.1 fA), accuracy ±(2.0% of rdg. +30 dgt.)
200 pA range (1.0 fA resolution), accuracy ± (1.0% of rdg. +30 dgt.)
2 nA range (10 fA resolution), accuracy ± (0.5% of rdg. +20 dgt.)
20 nA range (100 fA resolution), accuracy ± (0.5% of rdg. +10 dgt.)
200 nA range (1 pA resolution), accuracy ± (0.5% of rdg. +10 dgt.)
2 μA range (resolution 10 pA), accuracy ± (0.5% of rdg. +10 dgt.)
20 μA range (100 pA resolution), accuracy ± (0.5% of rdg. +10 dgt.)
200 μA range (1 nA resolution), accuracy ± (0.5% of rdg. +10 dgt.)
※2 mA range (resolution 10 nA), accuracy ±(0.5% of rdg. +30 dgt.)
(1) Measurement speed setting: SLOW2=When internal accumulation time is 13 PLCs
(2) Temperature range: 23 ±5℃ Humidity 85% rh or less
(3) 2 mA range selectable only when measuring speed FAST
Resistance Display Range 50 Ω ~2×10 ^19 Ω
Current measurement accuracy is defined by current range accuracy and voltage setting accuracy.
Voltage Setting Range (Accuracy) [SM7120, SM7120 common]
0.1 to 100.0 V, resolution 100 mV, accuracy ±0.1%±0.05% f.s. of setting.
100.1 to 1000 V, resolution 1 V, accuracy ±0.1% ±0.05% f.s. at setting.
[SM7120 only]
1000 to 2000 V, Resolution 1 V, Accuracy ±0.2% ±0.10% f.s. as set.
restrictor 0.1~250.0 V: 5/ 10/ 50 mA, 251~1000 V: 5/ 10 mA, 1001V~: 1.8mA
Measurement time setting Delay time: 0 to 9999 ms
functionality Comparative measurement, Deviation measurement, Percentage measurement, Surface resistivity measurement, Volume resistivity measurement, Voltage monitor, Contact inspection
Programming Functions 10 discharge-charge-measure-discharge measurement sequences programmable
demonstrate LCD display (30 digits, 8 lines), backlight, high voltage warning display
connector GP-IB, RS-232C, USB, EXT I/O
power supply AC100 to 240 V, 50/60 Hz, 45 VA
Volume and weight 330W × 80H × 400D mm, 6.7 kg
attachment (email) Power cord ×1, Instruction manual ×1, Short-circuit plug, CR-R (various drivers)
Expand More
High Resistance Meter SM7120High Resistance Meter SM7120

Click to enquire

Product consultation and purchase:18218718851

I already understand