Product Overview: Fluke 771 Milliamp Process Clamp Meter
Need more time?
No need to disconnect the circuit when performing 4-20 mA signal measurements and saves time.
Are you spending valuable time?
- Perform mA measurements by removing wiring and disconnecting circuits
- Calling the control room to isolate the circuit
- Testing analog inputs/outputs on the console
- Troubleshooting devices with mA inputs and outputs
- Troubleshooting 4-20 mA circuits that have intermittent problems or are unstable
- Return to Workshop for additional tools
If you are always busy and never have enough time, try the Fluke 771 milliamp clamp meter. These clamp meters save you time and money by eliminating the need to perform time-wasting activities. Now you can diagnose and repair 4-20 mA circuits without having to disconnect the loop or shut down the system.
Here are some ways the Fluke 771 Clamp Meter can help you:
| Milliamp Clamp Meter Features | appliance | How to save time and money |
| Measure mA signals from analog I/Os of PLCs and control systems without disconnecting the loop | Measurement of weak direct current | Correlate process indications with real physical values |
| Measurement of the output signal of the transmitter without disconnecting the loop | Maintenance and diagnostics of process and automation equipment without having to disconnect the circuits | No interruption to the process |
| Detachable clamp meter with extension cable | Performs measurements in tight spaces | Allows measurements to be made in a variety of difficult situations |
| Measuring Spotlights | Illuminates hard-to-find wiring in dark enclosures | Easier and faster measurement process |
| Measures up to 99.9 mA of current in a non-contact manner | Wide range | Measurement of 10 to 50 mA signals in old control systems |
| Automatic power off | Automatically turns off backlight and spotlight after 15 minutes and 2 minutes | Extended battery life |
Product Specification: Fluke 771 mA Process Clamp Meter
| Technical indicators | ||
| Measurable wire diameter | 0.177 in or 4.5 mm (maximum) | |
| operating temperature | -10 to 50 °C | |
| storage temperature | -25 to 60 °C | |
| Operating humidity | < 90% at < 30 °C, < 75% at 30 - 55 °C | |
| Working altitude | 0 to 2000 m | |
| IP Protection Rating | IP 40 | |
| sizes | 59 x 38 x 212 mm (2.32 x 1.5 x 8.35 in) | |
| weights | 260 g (9.1 oz) | |
| vibratory | Randomness 2 g, 5 to 500 Hz | |
| under attack | 1 m height drop test (except jaws) | |
| EMI/RFI | Conforms to EN61326-1 | |
| Regarding current measurements with jaw clamps. | ||
| Add 1 mA to the specification for EMC field strengths from 1V/m to 3V/m. | ||
| temperature coefficient | 0.01% °C ( 28 °C) | |
| Power supply and battery life | (2) AA 1.5 V alkaline batteries, IEC LR6, typically 40 hours | |
| warranty period | Three years of electronics | |
| One year warranty on cables and clamp meter accessories | ||
| Functional specifications | ||
| mA Measurement (measured by clamp meter) |
Resolution/Range | 0 to 20.99 mA |
| accurate | 0.2% + 2 characters | |
| Resolution/Range | 21.0 mA to 100.0 mA | |
| accurate | 1% + 5 words | |
Model: Fluke 771 Milliamp Process Clamp Meter
Fluke 771
Fluke 771 mA Process Clamp Meter
Annexes.
- Soft Carrying Case
- user manual
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.