This product is currently out of stock and unavailable.

Main characteristics

Main features and benefits:

  • Measuring range: -35°C to 850°C/-31°F to 1562°F (568-2) or -35°C to 750°C/-31°F to 1382°F (566-2)
  • Easy access to advanced functions with soft key buttons and dot matrix display
  • Measures objects at greater distances and smaller sizes with D:S ratios up to 55:1 (568-2) or 35:1 (566-2)
  • Compatible with all standard miniature connector K-type thermocouples, preserving investment in thermocouples
  • Adjustable radiation coefficient function (built-in material table) allows users to measure a wide range of surfaces with confidence
  • Stores multiple data points (up to 99 for the 568-2 and up to 50 for the 566-2) for later download and recall
  • 2 levels of backlight brightness to easily adapt to various lighting conditions
  • Audible and visual alarms to alert the user if the measured value exceeds the set limit value
  • Quickly identify problems with minimum, maximum, average and DIF functions
  • Included K-type thermocouple bead probe allows for immediate contact measurement
  • 1 % Measurement Accuracy Gives Users Peace of Mind When Servicing Equipment
  • Multi-functional interface available in 6 languages
  • Adjustable emissivity setting improves measurement accuracy

The following features are specific to 568-2:

  • Easily view data trends and analyze with included FlukeView® Forms software
  • Fast download of stored data via USB interface
  • Instant access to data using USB port and laptop without leaving the site
  • The digital pyrometer draws power from a laptop via the USB port, extending battery life
  • The Fluke 568-2 can be mounted on a tripod and the IR reading can be locked (equivalent to holding the trigger all the way down)
  • Software and USB cable included

Product Overview: Fluke 566-2/568-2 Infrared Contact Thermometer

Infrared and contact 2-in-1 pyrometer with innovative dot-matrix display.With a simple 3-button on-screen menu interface (in 6 languages), the Fluke 566-2/568-2 Digital Laser Thermometer makes complex measurements incredibly easy. With just a few button presses, you can quickly navigate through advanced functions to adjust emissivity, initiate data logging, or turn alarms on and off.

The Fluke 566-2/568-2 contact and non-contact 2-in-1 pyrometers feature a rugged, easy-to-use, user-friendly design that can easily handle demanding industrial, electrical and mechanical environments. These tools go far beyond the performance of other infrared thermometers (or pyrometers), allowing users to achieve higher productivity in a wider range of applications.

Product Specifications: Fluke 566-2/568-2 Infrared Contact Thermometer

Product Specifications
model number 566-2 568-2
Infrared temperature range -35°C to 750°C (-31°F to 1382°F) -35°C to 850°C (-31°F to 1562°F)
Infrared thermometry accuracy < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
> 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
Display resolution 0.1 °C / 0.1 °F
Infrared spectral response 8 µm to 14 µm
Infrared Response Time < 500 msec
K-Type Thermocouple Input Temperature Range -270 °C to 1372 °C (-454 °F to 2501 °F)
K-Type Thermocouple Input Accuracy -270°C to -40°C: ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F))
-40 °C to 1372 °C: ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
D:S (ratio of distance to diameter of measured spot) 35:1 55:1
laser aiming Single point laser < 1 mw output, Class 2 (II) operation, 630 nm to 670 nm
Minimum spot diameter 19 mm (0.75 inches)
Emissivity Adjustment Adjustable from 0.10 to 1.00 in 0.01% increments via built-in common material meter or digitally.
Data storage with date/time stamp 50 points. 99 points.
PC interfaces and cables not have USB 2.0 and FlukeView® Forms Software
High/Low Alarm  Audible and two-color visual alarms
Min/Max/Ave/DIF  be
demonstrate  98 x 96 pixel dot matrix with function menu
do sth. with one's back to the light  Two levels, normal backlighting and super bright backlighting for darker environments
Trigger Lock  be
Switchable Celsius and Fahrenheit  be
power supply 23,58333333 2 AA/LR6 Batteries
23,66666667 2 AA/LR6 batteries, powered via USB when used with a computer
Battery life If used continuously: 12 hours with laser and backlight on; 100 hours with laser and backlight off
operating temperature  0°C to 50°C (32°F to 122°F)
storage temperature  -20 °C to 60 °C (-4 °F to 140 °F)
K-Type Bead Thermocouple Temperature Range  -40 °C to 260 °C (-40 °F to 500 °F)
K-Type Bead Thermocouple Accuracy 0°C to 260°C (32°F to 500°F) temperature range, ± 1.1°C (2.0°F); -40°C to 0°C (-40°F to 32°F) temperature range: typically less than 1.1°C (2.0°F)

Model: Fluke 566-2/568-2 Infrared Contact Thermometer

Fluke 566-2/568-2
Fluke 566-2/568-2 Infrared Contact Spot Thermometer includes:
  • Type K Thermocouple Bead Probe
  • Durable Hard Case
  • 2 AA batteries
  • Getting Started Guide in 6 languages
  • USB 2.0 computer interface cable (F568-2 only)
  • Software (F568-2 only)
  • Two-year warranty