Main characteristics

stakeless test

The Fluke 1625-2 Ground Resistance Tester measures ground loop resistance using only the jaws. To use this measurement method, two jaws are clamped to a ground rod and each jaw is connected to the tester. The use of a grounding stake is not required at all. One jaw senses a known fixed voltage and the other jaw measures the current. The tester then automatically determines the resistance of the earth rod. This test method is only applicable if there is a grounding system in the building or structure under test, although this is true in most cases. If there is only one pathway to ground, as is the case in many residential applications, and the stakeless test method does not provide an acceptable value, then the potential drop test method must be used.

With stakeless testing, there is no need to disconnect ground rods - the integrity of the bonded grounding system is maintained during the test. Now there's no need to spend time placing and connecting stakes to ground rods on the system, which can be a huge time saver. You can also perform grounding tests in locations you've never considered before, including inside buildings, cable towers, or anywhere you can't reach the ground.

Full-featured tester

The Fluke 1625-2 is a ground tester with a difference, performing all four types of ground measurements:

  • Three- and four-pole potential drops (using ground stakes)
  • Quadrupole soil resistivity test (using ground stakes)
  • Selective testing (using ground stake and 1 jaw)
  • Stakeless testing (using only 2 jaws)

SKU:Fluke 1625-2 Category. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Overview: Fluke 1625-2 Ground Resistance Tester

The Fluke 1625-2 Ground Resistance Tester is capable of storing and downloading data via a USB port. Best-in-class accessories help simplify and speed up testing time.

  • Three-pole and four-pole potential drop ground resistance loop testing
  • Quadrupole soil resistivity test
  • Selective ground rod test using 1 jaw
  • Stakeless ground rod test using 2 jaws
  • IP56 protection for outdoor use
  • Hard Carrying Case
  • USB data storage and transfer

What's more, the tester is easy to use. With each test, the tester prompts you for the ground stake or jaws you need to use; a large rotary switch ensures that you can operate it even with gloves on.

Product Specification: Fluke 1625-2 Ground Resistance Tester

General technical indicators
memory (unit) Access to up to 1500 records stored in internal memory via USB port
measurement function Interference voltage and frequency, 3-pole and 4-pole earth resistance with/without clamp-on current transformers, 2-pole AC resistance, 2-pole and 4-pole DC resistance
monitor 4 digits (2999 digits) - 7-segment LCD (improved visibility)
manipulate Center rotary switch and function keys
temperature range
operating temperature -10 °C to 50 °C (14 °F to 122 °F)
storage temperature -30 °C to 60 °C (-22 °F to 140 °F)
temperature coefficient ± 0.1% /°C of reading 28 °C
Type of protection Protection class IP56 for the housing and IP40 for the battery cover according to EN60529.
Maximum voltage Warning - Socket "jaws" to socket E, ES, S or H
Urms = 0 V
Sockets E, ES, S, or H in any combination with each other, max.rms = 250 V (misuse)
safety Protected by double and/or reinforced insulation. Max. 50 V to earth (according to IEC61010-1). Pollution class 2
quality standard Developed, designed and manufactured according to DIN ISO 9001 standards
influence of external fields Conforms to DIN 43780 (8/76)
auxiliary power 6 x 1.5 V alkaline batteries (IEC LR6 or AA type)
Battery life range With IEC LR6/ AA types: typically 3,000 measurements (RE+RH ≤ 1 kΩ)
With IEC LR6/ AA types: typically 6,000 measurements (RE + RH > 10 kΩ)
Dimensions (W x H x D) 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)
weights ≤ 1.1 kg (2.43 lb) (without accessories); 7.6 kg (16.8 lb) (with accessories and battery in carrying case)
Housing Material polyesters
Interference voltage DC + AC measurement (UST)
Measurement error limits: methods full-wave rectifier (FWR)
Measurement range 1 V to 50 V
Display range 0.0 V to 50 V
resolution (of a photo) 0.1 V
frequency range AC/DC 45 Hz to 400 Hz sine wave
accurate ± (5% + 5 digits of reading)
measurement sequence Approx. 4 measurements/second
internal resistance Approx. 1.5 MΩ
Maximum overload Urms = 250 V
Measurement of interference frequency (F)
Measurement error limits: methods Measurement of the oscillation period of the disturbance voltage
measuring range 6.0 Hz to 400 Hz
Display range 16.0 Hz to 299.9 Hz to 999 Hz
resolution (of a photo) 0.1 Hz to 1 Hz
range (of scales or measuring equipment) 1 V to 50 V
accurate ± (1% + 2 digits of reading)
Ground resistance (RE)
Measurement Methods Measurement of current and voltage with probes according to IEC 61557-5
open circuit voltage 20/48 V, AC
short-circuit current 250 mA (AC)
Measurement frequency Manual or automatic selection of 94, 105, 111 and 128 Hz (AFC), in function R¹ 55 Hz
noise suppression 120 dB (16 2/3, 50, 60 and 400 Hz)
Maximum overload to ground Urms = 250 V
Electrical measurement specifications
Inherent error or amount of influence Terms of reference or designation of scope of work Symbol Code Required or tested according to the relevant parts of the IEC1557 standard. Test Type
inherent error reference condition A Part 5, section 6.1 R
placement Reference position ±90 ° E1 Part 1, section 4.2 R
Supply Voltage at the limit values specified by the manufacturer E2 Part 1, sections 4.2 and 4.3 R
temp 0 °C and 35 °C E3 Part 1, section 4.2 T
Series Interference Voltage See Sections 4.2 and 4.3. E4 Part 5, sections 4.2 and 4.3 T
Probe and auxiliary grounding electrode resistance 0 to 100 x RA but ≤ 50 kΩ E5 Part 5, section 4.3 T
system frequency 99% to 101% for nominal frequency E7 Part 5, section 4.3 T
system voltage 85% to 110% for nominal voltage E8 Part 5, section 4.3 T
operating error B = ±(|A| + 1,15 √E²)1 E²2 E²3 E²4 E²5 E²) Part 5, section 4.3 R
B[%] = ± B/base x 100%

A = inherent error
En = Deviation
R = Routine test
T = Type Test

measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
0.300 kΩ to 2.999 kΩ
3.00 kΩ to 29.99 kΩ
30.0 kΩ to 299.9 kΩ
resolution (of a photo) 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100 Ω
accurate ± (2% + 2 digits of reading)
operating error ± (5% + 5 digits of reading)
measuring time Typically 8 seconds for fixed frequencies, maximum 30 seconds with automatic frequency control, to complete all measured frequency cycles.
Additional errors due to resistance of the probe and auxiliary grounding electrode RH(RS + 2000 Ω)/RE x 1.25 x 10-6% + 5 digits
RH and RS measurement error At a fixed frequency it is usually RE + RS + RH 10%
Maximum Probe Resistance ≤ 1 MΩ
Maximum auxiliary grounding electrode resistance ≤ 1 MΩ
If the error is within the limits required by IEC61557-5, it is automatically checked.
If conditions cause the measurement error after measuring the probe, auxiliary ground electrode and ground resistance to exceed 30%, the display will show a warning symbol and indicate that RS or RH is too high.
The automatic switching of the measurement resolution depends on the auxiliary grounding electrode resistance RH
Umeas = RH at 48 V < 300 Ω
< 6 Ω
< 60 Ω
< 600 Ω
Umeas = RH at 20 V < 250 Ω
< 2.5 kΩ
< 25 kΩ
< 250 kΩ
resolution (of a photo) 1 mΩ
10 mΩ
100 mΩ
1 Ω
Selective earth resistance measurement (RE jaws)
Measurement Methods Measurement of currents and voltages with probes according to EN 61557-5 and measurement of currents in individual branch circuits with an additional transformer.
open circuit voltage 20/48 V, AC
short-circuit current 250 mA (AC)
Measurement frequency Manual or automatic selection 94, 105, 111 and 128 Hz (AFC), 55 Hz (R¹)
noise suppression 120 dB (162/3, 50, 60 and 400 Hz)
Maximum overload to ground Maximum Urms = 250 V (measurement will not be initiated)
measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
0.300 kΩ to 2.999 kΩ
3.00 kΩ to 29.99 kΩ
resolution (of a photo) 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
accurate ± (7% + 2 digits of reading)
operating error ± (10% + 5 digits of reading)
Additional errors due to typical electrode resistance of the probe and auxiliary grounding RH(RS + 2000 Ω)/RETOTAL x 1.25 x 10-6% + 5 digits
RH and RS measurement error At a fixed frequency it is usually RETOTAL + RS + RH 10%
measuring time Typically 8 seconds at a fixed frequency using automatic frequency control, maximum 30 seconds to complete all measured frequency cycles.
Minimum current of a single branch to be measured 0.5 mA Use of transformers (1000:1)
0.1 mA Use of transformers (200:1)
Maximum disturbance current through the transformer 3 A Use of transformers (1000:1)
1. Use recommended current clamps/transformers.
Resistance Measurement (R~)
Measurement Methods Measurement of current and voltage
measured voltage 20 V AC, rectangular pulse
short-circuit current > 250 mA (AC)
Measurement frequency Manual or automatic selection of 94, 105, 111 and 128 Hz (AFC)
measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
300 Ω to 2999 Ω
3.00 kΩ to 29.99 kΩ
30.0 kΩ to 299.9 kΩ
resolution (of a photo) 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100 Ω
accurate ± (2% + 2 digits of reading)
operating error ± (5% + 5 digits of reading)
measuring time Usually 6 seconds
Maximum interference voltage 24 V, measurement cannot be started beyond 24 V
Maximum overload Urms Maximum value = 250 V
Resistance measurement (R DC)
Measurement Methods Current-voltage measurements according to IEC 61557-4 possible
measured voltage DC 20 V
short-circuit current 250 mA DC
Formula for measured values For quadrupole measurements, the H, S, and ES leads can be extended without additional error.
Resistance > 1 Ω in conductor E can lead to an additional error of 5m Ω/Ω.
measuring range 0.020 Ω to 300 kΩ
Display range 0.001 Ω to 2.999 Ω
3.00 Ω to 29.99 Ω
30.0 Ω to 299.9 Ω
300 Ω to 2999 Ω
3.0 kΩ to 29.99 kΩ
30.0 kΩ to 299.9 kΩ
resolution (of a photo) 0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100 Ω
accurate ± (2% + 2 digits of reading)
operating error ± (5% + 5 digits of reading)
measurement sequence Approx. 2 measurements/second
measuring time Typically 4 seconds, including polarity reversal (bipolar or quadrupolar)
Maximum interference voltage DC or AC voltage ≤3 V, measurement cannot be started beyond 3 V
Maximum Sensitivity 2 Henry
Maximum overload Urms = 250 V
Compensation for measuring wire resistance (RK)
In the function RE Triode, RE In the four-pole (jaws), R AC and R DC diodes, you can turn on the compensation for measuring the resistance of the wire (RK)
Formula for measured values Rdemonstrate = Rsurveying - Rreparation²
2. The setpoint input value RK = 0.000 Ω is measured by adjusting the measurement to vary within the range of 0.000 to 29.99 Ω.
Stakeless ground loop measurement (double jaw, stakeless)
Switching gears RA Quadrupole (Double Jaw, No Stake)
resolution (of a photo) 0.001 Ω to 0.1 Ω
measuring range 0.02 Ω to 199.9 Ω
accurate ± (7% + 3 digits of reading)
operating error ± (10% + 5 digits of reading)
measured voltage Vm = 48 V AC (primary voltage)
Measurement frequency 128 Hz
Noise Current (IEXT) Maximum IEXT = 10 A (AC) (RA < 20 Ω)
Maximum IEXT = 2 A (AC) to ground (RA > 20 Ω)
Measurement principle: Stake-free measurement of the resistance in a closed loop using two current transformers.
Automatic range selection.
The information about the measurement of the stakeless ground loop is valid only if the measurement is carried out with the recommended current clamp at the specified minimum distance.

Model: Fluke 1625-2 Ground Resistance Tester

Fluke 1625-2
Fluke 1625-2 GEO Earth Ground Tester

Included:

  • Ground Tester
  • user manual
  • batteries
  • Quick Reference Guide
  • USB cable
Expand More