Product Overview: Fluke NORMA 5000 High Accuracy Power Analyzer
Fluke Norma Power Meters|Power Analyzers: Reliable, Highly Accurate Measurement Tools for Power Electronics Test and Development
The compact Fluke Norma series of power detection analyzers/power meters offers new measurement techniques to help engineers involved in the development and testing of motors, inverters, lighting, power supplies, transformers and automotive parts make their products more productive.
The Fluke Norma Series Power Detection Analyzers/Power Meters feature a high-bandwidth architecture that enables precision measurements of single-phase or three-phase currents and voltages, harmonic analysis, Fast Fourier Transform (FFT) analysis, and the calculation of power and other calculated values.
This power detector/power meter series includes the Fluke Norma 4000 three-phase power analyzer and the Fluke Norma 5000 six-phase power detection analyzer/power meter. These rugged, high-precision power detection analyzers/power meters offer a good price/performance ratio and are convenient and reliable for use either in the field or as benchtop instruments in the lab or on the test bench.
Applications:
- Power Detection and Analysis for Electric Motors and Inverter Drive Systems - The Power Meter accurately measures switching losses caused by inverters through exhaustive spectral analysis and dynamic torque calculations, and is capable of comprehensively evaluating torque transients and harmonics at high frequencies.
- Inverter Drive System Power Detection and Analysis - The Power Meter measures all electrical and mechanical power parameters within the same event window simultaneously, allowing the user to observe the effect of one component on another, or its effect on the entire system.
- Lighting System Power Detection and Analysis - With a bandwidth of up to 10 MHz and a high sampling rate of up to 1 MHz, the Power Meter analyzes the rectifier output signal in detail. The shunt technology enables power detection at very high frequencies. At the same time, the ability to measure input and output power provides rectifier loss calculation capability.
- Transformer Power Measurement and Analysis - The power meter measures 6-phase power synchronously, calculates the efficiency and losses of high-power transformers with high accuracy even at very low power factors, and is also able to measure the resistance of multi-phase transformer coils synchronously.
- Automotive Power Detection and Analysis - Power meters measure electrical inputs and mechanical outputs simultaneously, providing data on the efficiency and losses of individual parts as well as the entire drive system.
Product Specification: Fluke NORMA 5000 High Accuracy Power Analyzer
| General technical specifications | ||
| phase (math.) | 1 to 3 | |
| weights | Approx. 5 kg (11 lb) | |
| sizes | 150 x 237 x 315 mm | |
| 5.9 x 9.3 x 12.4 in | ||
| Built-in printer | not have | |
| monitor | Color, 5.7 in / 144 mm - 320 x 240 pixels | |
| User-selectable backlight illumination and contrast ratio | ||
| bandwidths | DC max. 3 MHz or DC max. 10 MHz, depending on input module | |
| Basic precision | 0.2%, 0.1%, or 0.03%, depending on input module | |
| sampling rate | 0.33 MHz or 1 MHz, depending on input module | |
| Voltage input range | 0.3 V to 1000 V | |
| Current input range (direct input, without shunt) | 0.03 mA or 20 A, depending on input module | |
| Configuration memory | 4 MB | |
| Setting the memory | 0.5 MB | |
| Fast Fourier Transform (FFT) | Up to 40th harmonic | |
| RS-232/USB interface | standard lens | |
| PI1 Processing Interface (8 analog/pulse inputs and 4 mode outputs) | selectable | |
| IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s) | selectable | |
| Fluke NormaView PC software (for data download, analysis and report writing) | standard lens | |
| Basic Functions | ||
| Fast Fourier Transform (FFT) | Harmonics are calculated and identified graphically. Up to 3 harmonic spectra can be displayed simultaneously. | |
| Measured values: U, I and P per phase. | ||
| Order: 1st to 40th harmonic, maximum half sampling frequency | ||
| Digital Oscilloscopes (DSO) | Display up to 3 measurements (samples) simultaneously. Quickly view waveforms and distortion. | |
| Integral function (energy) | Displays up to 6 configurable numeric values simultaneously. Start/stop conditions and positive/negative options. | |
| vector display | Displays a vector plot of up to 6 signals from the HO1. This makes it easy to test the proper connection of the instrument and to quickly view the phase angle of each signal. | |
| logger | Displays the average value over a certain period of time for trend analysis. | |
| RAM Data storage | Storage of sampling values and averages; start/stop condition settings. | |
| Approximately 4MB is available for storing measured values. | ||
| configure | Set the analyzer to measure and display data in the desired format. | |
| environmental conditions | ||
| Operating Temperature Range | 5 °C to 35 °C (41 °F to 95 °F) | |
| Storage temperature range | -20 °C to 50 °C (-4 °F to 122 °F) | |
| Housing Material | The Fluke Norma power analyzer is very compact and features a solid metal case to meet demanding EMC requirements. | |
| climatic scale | KYG DIN 40040, max. 85% Relative humidity, non-condensing. | |
| power supply | 85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, approx. 40 VA Europlug with switch. Current terminals of the same type are available. | |
| Measurement input | Safety jacks, 4 mm, 2 per input. The external shunt is connected via BNC socket. | |
| manipulate | Membrane keys with cursor, function keys and command functions. | |
| grout | Rear panel of the three-phase analyzer | |
| measured value | ||
Seamlessly calculates the average value of each input. In a three-phase system, the total power and average voltage and current of the three phases are also calculated. In synchronized mode, these values are also calculated for the fundamental waveform H01.
|
||
| Frequency and Synchronization | ||
| range (of scales or measuring equipment) | DC and 0.2 Hz to sample rate | |
| precision | ±0.01 % Measured value (reading) | |
|
||
| Configuration Storage | ||
| Up to 15 sets of user configurations can be saved to permanent memory and subsequently recalled. Unsaved changes are lost when the instrument is turned off. | ||
| connector | ||
| RS232 interface for upgrading firmware and exchanging data with a PC. A printer can be connected via an external converter. | ||
| option | IEEE 488.2/1 MBps | |
| Ethernet / 10 MBit/s or 100 Mbit/s | ||
| Standards and safety | ||
| Electrical Safety | EN 61010-1/ 2nd edition 1000 V CAT II (600 V CAT III) | |
| Pollution Class 2, Safety Class I | ||
| Transformers to EN 61558 | ||
| Annex to EN 61010-2-031/032 | ||
| Maximum Input | Measurement range of 1000 Veff, 2 kVpeak for voltage inputs | |
| Measurement range of 10 Aeff, 20 Apeak for current inputs | ||
| test voltage | net import | Enclosure (protective conductor): 1.5 KV AC |
| grid connection | Measurement input: 5.4 kV AC | |
| Measurement input | Enclosure: 3.3 kV AC | |
| Measurement input | Input: 5.4 kV | |
| electromagnetic sensitivity | radiation standard | IEC 61326-1, EN 50081-1, EN 55011 Class B |
| immunity | IEC 61326-1 / Appendix A (industrial part), EN 50082-1 | |
Power Phase
Fluke Norma 4000 功率分析仪最多可配备三个电源相位。用户可以选择适合其应用的电源相位。
Each modular plug-in power phase includes both voltage and current measurement channels. Each measurement channel applies to each base unit, but only one channel can be used per unit. Check the standard configuration.
Power Phase Overview
| Power Phase Channel | ||
| PP42 | precision | 0.2% (0.1% rd + 0.1% rg) |
| Current range | 20 A | |
| sampling rate | 341 kHz | |
| bandwidths | 3 MHz | |
| PP50 | precision | 0.1% (0.05% rd + 0.05% rg) |
| Current range | 10 A | |
| sampling rate | 1 MHz | |
| bandwidths | 10 MHz | |
| PP54 | precision | 0.1% (0.05% rd + 0.05% rg) |
| Current range | 10 A | |
| sampling rate | 341 kHz | |
| bandwidths | 3 MHz | |
| PP64 | precision | 0.03% (0.02% rg + 0.01% rg) |
| Current range | 10 A | |
| sampling rate | 341 kHz | |
| bandwidths | 3 MHz | |
splitter
| plane shunt | |
| Continuous load (Imin) Range (Imax) |
0.3 A |
| 32 A | |
| Rated current (calibration point) | 32 A |
| Basic accuracy of calibration points [%] | ± 0.03 |
| Basic Accuracy of Rated Current [%] | ± 0.03 |
| Rated voltage drop [V] | 320 mV |
| Nominal Resistance [Ohm] | 10 mΩ |
| Short-time over-range (5s load 15s interval) |
100A/ 1s-5s |
| Overload Wmax | - |
| bandwidths | DC - 1 MHz |
| frequency range | - |
| Angular accuracy [ °/kHz] | ± 0.1 |
| Frequency impact [%/kHz] | - |
| Load Impact [%/A2] | - |
| Temperature coefficient [ppm/K] | ≤10 |
| Weight (kg / lbs) | 0.62 /1.36 |
| 三轴分流器 | |||
| Continuous load (Imin) Range (Imax) |
0.1 A | 1 A | 6 A |
| 30 A | 100 A | 300 A | |
| Rated current (calibration point) | 10 A | 30 A | 100 A |
| Basic accuracy of calibration points [%] | ± 0.03 | ± 0.03 | ± 0.1 |
| Basic Accuracy of Rated Current [%] | ± 0.03 | ± 0.03 | ± 0.1 |
| Rated voltage drop [V] | 100 mV | 30 mV | 20 mV |
| Nominal Resistance [Ohm] | 10 mΩ | 1 mΩ | 0.2 mΩ |
| 短时超量程(5s 负载 15s 间隔) | 35 A | 200 A | 450 A |
| Overload Wmax | 90 W | 200 W | 2 kW |
| bandwidths | 2 MHz | 2 MHz | 1 MHz |
| frequency range | 0 至 500 kHz | 0 至 200 kHz | 0 至 100 kHz |
| Angular accuracy [ °/kHz] | ± 0.001 | ± 0.002 | ± 0.002 |
| Frequency impact [%/kHz] | ± 0.0015 | ± 0.0015 | ± 0.01 |
| Load Impact [%/A2] | 1 x 10-6 | 1 x 10-6 | 1 x 10-6 |
| Temperature coefficient [ppm/K] | ≤15 | ≤15 | ≤10 |
| Weight (kg / lbs) | 0.75 / 1.65 | 0.75 / 1.65 | 1.2 / 2.65 |
| 三轴分流器(续) | |||
| Continuous load (Imin) Range (Imax) |
2 A | 18 A | 18 A |
| 450 A | 1000 A | 1500 A | |
| Rated current (calibration point) | 150 A | 300 A | 500 A |
| Basic accuracy of calibration points [%] | ± 0.1 | ± 0.1 | ± 0.1 |
| Basic Accuracy of Rated Current [%] | ± 0.1 | ± 0.1 | ± 0.1 |
| Rated voltage drop [V] | 75 mV | 15 mV | 30 mV |
| Nominal Resistance [Ohm] | 0.5 MΩ | 0.06 MΩ | 0.06 MΩ |
| 短时超量程(5s 负载 15s 间隔) | 650 A | 1500 A | 2000 A |
| Overload Wmax | 10 kW | 7.5 kW | 10 kW |
| bandwidths | DC - 500 MHz | DC - 500 kHz | DC - 200 kHz |
| frequency range | 0 至 100 kHz | 0 至 20 kHz | 0 至 20 kHz |
| Angular accuracy [ °/kHz] | ± 0.025 | ± 0.025 | ± 0.025 |
| Frequency impact [%/kHz] | ± 0.03 | ± 0.03 | ± 0.03 |
| Load Impact [%/A2] | 0.5 x 10-6 | 0.2 x 10-6 | 0.5 x 10-6 |
| Temperature coefficient [ppm/K] | ≤10 | ≤10 | ≤10 |
| Weight (kg / lbs) | 6 / 13.2 | 5.3 / 11.7 | 6 / 13.2 |