Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters

Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters

Main characteristics

  • True RMS measurement ensures accuracy of complex, non-sinusoidal waveform measurements
  • 40 mm clamp opening
  • Maximum resolution of 1 μA, minimum range down to 3 mA (maximum measurement current 60 A)
  • Option to turn on the filter function to eliminate noise in non-operating frequency bands
  • Max/Min/Ave readout and hold function
  • Forward-facing LED work light to assist in dark wiring closets
  • With backlit display; automatic backlight off and auto power off function can prolong battery life
  • CAT III 600V safety rating
  • Internal memory recording: up to 65,000 measurement points

SKU:Fluke 368/CN Category. Brand.

Inquire about this product

Product Overview: Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters

Reduced downtime - find leakage currents without removing equipment from the production line

The Fluke 368 FC True RMS Leakage Current Clamp Meter helps users continuously detect, archive, record and compare leakage current readings to prevent unplanned downtime and detect GFCI and RCD intermittent trips in a timely manner, all without removing the equipment from the production line.

The Fluke 368 FC has a large 40 mm jaw diameter for use with large conductors. The clamp meter jaws are fully shielded to accurately capture very weak leakage signals while minimizing external electromagnetic interference.

The 368 FC is also available with wireless data connectivity through Fluke Connect. As part of the industry's largest software system, Fluke Connect®, and with more than 40 wireless test tools, the 368 FC allows you to continuously track changes in leakage current, helping to identify potential faults and preventing small problems from leading to serious failures.

*The 368 has the same electrical performance and measurement functions as the 368 FC, except for FC and related functions.

FlukeConnect-China_0

Product Specifications: Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters

Electrical specifications
measurement function alternating current (electricity)
AC current range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range Selection mA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
Range/Resolution 3 mA¹ / 0.001 mA
30 mA / 0.01 mA
300 mA / 0.1 mA
3 A / 0.001 A
30 A / 0.01 A
60 A / 0.1 A
Accuracy - activate filter (40 to 70 Hz), deactivate filter (40 to 1 kHz)² 3 mA - 30 A
60 A
1% + 5 bits
2% + 5 bits
frequency 40 Hz to 1 kHz
crest factor ="3"
Accuracy is valid for one year after calibration. Accuracy is expressed as ± (1 TP3T reading + digits) for reference temperature conditions of 23 ± 5 °C and a maximum relative humidity of 801 TP3T.
¹Minimum value is 10 μA true RMS.
² Exceeds TC / °C 18 °C to 28 °C, 0.02 + 1
Airframe Features
Display (LCD) Digital readout: 3300 characters
Display update rate 4 times/second
Maximum measurable wire diameter 40 mm
sizes 234 x 101 x 46 mm
weights 500 g
batteries 2 AA, IEC LR6, NEDA 15A, Alkaline
Battery life Estimated battery life of over 150 hours without backlight or spotlight
automatic shutdown Clamp meter will automatically shut down after 15 minutes of inactivity.
Safety and environmental norms
General security IEC 61010-1: Pollution class 2
Measurement Safety IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
operating temperature -10 °C to +50 °C
storage temperature -40 °C to +60 °C
Operating humidity Non-condensing (<10 °C)
90% Relative humidity (10 °C to 30 °C)
75% Relative humidity (30 °C to 40 °C)
45% Relative humidity (40 °C to 50 °C)
protection class IEC 60529: IP30 (jaws closed)
Working altitude 2000 m
Storage altitude 12000 m
Current Sensor Action Category IEC 61557-13: Class 2, ≤ 30 A/m
Electromagnetic Compatibility (EMC)
international standard
IEC 61326-1 Industrial Electromagnetic Environment
CISPR 11 Group 1, category B
Group 1 The need to generate and/or use RF energy associated with conducted energy within the device is essential for the device's own internal functioning.
Level B The equipment is suitable for household appliances and any equipment directly connected to the low voltage network supplying residential buildings. The emission levels specified in the CISPR 11 requirements may be exceeded when this equipment is connected to the test target.
Korea (KCC): Type of equipment (industrial radio and communication equipment)
Grade A This product meets the requirements for industrial electromagnetic equipment and the seller or user should take care. This equipment is designed for use in a commercial environment, not a residential environment.
USA (FCC): 47 CFR 15 Subpart B. This product may be considered tax-exempt equipment under the provisions of Part 15.103.

Model: Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meter

Fluke 368 FC
Fluke 368 FC/CN Microamp True RMS Leakage Current Clamp Meter

Random Accessory

  • Leakage current clamp meter
  • Soft Carrying Case
  • Safety Manual
  • Batteries: 2 AA
Fluke 368 CN

Fluke 368 CN Microamp True RMS Leakage Current Clamp Meter

  • Leakage current clamp meter
  • Soft Carrying Case
  • Safety Manual
  • Batteries: 2 AA

F368/369FC Technical Data [please login to download and view]

F369/368FC Instruction Manual [please login to download and view]

Expand More
Fluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp MetersFluke 368/CN and 368 FC/CN Microamp True RMS Leakage Current Clamp Meters

Click to enquire

Product consultation and purchase:18218718851

I already understand