Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe

Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe

Main characteristics

  • CAT III 1500 V safety-rated clamp meter for safe measurements
  • Slim jaws for accessing cables in crowded combiner boxes
  • Rugged IP54 rating for outdoor use
  • Work Efficiently with DC Power Measurement, Audio Indicator Polarity and Visual Continuity

SKU:Fluke 393 FC Category. Brand.

Inquire about this product

Product Overview: 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe

The Fluke 393 FC CAT III 1500 V True RMS Solar Clamp Meter with iFlex is a tool designed for solar photovoltaic (PV) installation technicians and maintenance professionals working in high-voltage DC environments such as photovoltaic arrays, wind energy, electrified railroads, and data centers using UPS uninterruptible power supplies. The clamp meter measures voltages up to 1500 V DC and 1000 V AC through the test leads and currents up to 999.9 A DC or AC through the jaws. The included iFlex flexible current probe extends the range of AC current measurements to up to 2500 A. The 393 clamp meter has a slim jaw that allows you to reach cables in crowded convergence boxes. In addition, the test leads are designed with your work environment in mind and meet CAT III 1500 V DC safety requirements.

Other key features:

  • IP54 rated, especially suitable for outdoor work with solar arrays and wind energy systems
  • DC power measurements, readings in kVA
  • Audio indication of polarity helps prevent accidental misconnections
  • Visual Continuity provides a bright green light on the display, perfect for working in dark and noisy environments.
  • Record and report test results via Fluke Connect software
  • When measuring AC current, the included iFlex Flexible Current Probe allows you to easily and comfortably access cables in confined spaces. The iFlex probe twists in very small spaces and provides accurate current measurements.

Product Specifications: 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe

Specification:
General Information
Maximum voltage between any terminal and grounding
exchanges 1000 V
direct current (D.C.) 1500 V
batteries 2 AA IEC LR6 alkaline batteries
monitor Dual display with backlight
automatic shutdown 20 minutes.
electronic
accurate
Accuracy is valid for one year after calibration under the following conditions: operating temperature from 18 °C to 28 °C and relative humidity from 0% to 75%. Accuracy specifications are displayed in the following format: ±([% of reading] + [least significant digit word value]).
temperature coefficient For temperatures above 28 °C or below 18 °C, the accuracy changes by 0.1 times the specified accuracy for every 1 °C change in temperature.
AC current: through the jaws
range (of scales or measuring equipment) 999.9 A
resolution (of a photo) 0.1 A
accurate 2% + 5 bits (10 Hz to 100 Hz)
2.5% + 5 bits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz) 2.5 (at 600.0 A)
3.0 (at 500.0 A)
1.42 (at 999.9 A)
Increase >2 at C.F. >2
AC current: via flexible current probe
range (of scales or measuring equipment) 999.9 A
2500 A
resolution (of a photo) 0.1 A (≤999.9 A)
1 A (≤2500 A)
accurate 3% Reading + 5 bits (10 Hz to 500 Hz)
Crest Factor (50/60Hz) 2.5 (at 1400 A)
3.0 (at 1100 A)
1.42 (at 2500 A)
Increase >2 at C.F. >2
position sensitivity
NEC Symbol
optimal distance i2500-10 Flex i2500-18 Flex incorrect
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0%
Measurement uncertainty is determined when the primary center lead is in the optimal position, free of external electric or magnetic fields and within the operating temperature range.
direct current
range (of scales or measuring equipment) 999.9 A
resolution (of a photo) 0.1 A
accurate 2% Reading + 5 bits[1]
[1]When using the ZERO (B) function to compensate for deviation.
alternating current
range (of scales or measuring equipment) 600.0 V
1000 V
resolution (of a photo) 0.1 V (≤600.0 V)
1 V (≤1000 V)
accurate 1% Reading + 5 digits (20 Hz to 500 Hz)
dc voltage
range (of scales or measuring equipment) 600.0 V
1500 V
resolution (of a photo) 0.1 V (≤600.0 V)
1 V (≤1500 V)
accurate 1% Reading + 5 bits
millivolt DC
range (of scales or measuring equipment) 500.0 mV
resolution (of a photo) 0.1 mV
accurate 1% Reading + 5 bits
Current frequency: through the jaws
range (of scales or measuring equipment) 5.0 Hz to 500.0 Hz
resolution (of a photo) 0.1 Hz
accurate 0.5% reading + 5 bits
trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Current frequency: via flexible current probe
range (of scales or measuring equipment) 5.0 Hz to 500.0 Hz
resolution (of a photo) 0.1 Hz
accurate 0.5% reading + 5 bits
trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage Frequency
range (of scales or measuring equipment) 5.0 Hz to 500.0 Hz
resolution (of a photo) 0.1 Hz
accurate 0.5% reading + 5 bits
trigger level 5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC Power
range (of scales or measuring equipment) 600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
resolution (of a photo) 0.1 kVA
1 kVA
accurate 2% reading + 2.0 kVA
2% reading + 20 kVA
resistive
range (of scales or measuring equipment) 600.0 Ω
6000 Ω
60.00 kΩ
resolution (of a photo) 0.1 Ω (≤ 600.0 Ω)
1 Ω (≤ 6000 Ω)
0.01 kΩ (≤ 60.00 kΩ)
accurate 1% Reading + 5 bits
capacitors
range (of scales or measuring equipment) 100.0 μF
1000 μF
resolution (of a photo) 0.1 μF (≤ 100.0 μF)
1 μF (≤ 1000 μF)
accurate 1% Reading + 5 bits
Surge Trigger Level 5 A
Mechanical indicators
Dimensions (L x W x H) 281 mm x 84 mm x 49 mm
Weight (with battery) 520 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector) 1.8 m
Environmental requirements
operating temperature -10 °C to 50 °C
storage temperature -40 °C to 60 °C
Operating humidity Non-condensing (< 10°C)
≤ 90% Relative humidity (at 10 °C to 30 °C)
≤ 75% Relative humidity (at 30 °C to 40 °C)
≤ 45% Relative humidity (at 40 °C to 50 °C)
Working altitude 2000 m
Storage altitude 12,000 m
Protection (IP) Rating IEC 60529: IP54, non-operating condition
Electromagnetic Compatibility (EMC)
international standard IEC 61326-1: Portable Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Devices intentionally generate and/or use conductively coupled RF energy, which is necessary for operation within the device itself.
Class A: This type of equipment is suitable for non-domestic use and in any installation not directly connected to the low voltage network supplying residential buildings. It may be difficult to ensure electromagnetic compatibility in other environments due to conducted and radiated interference.
CAUTION: This device is not intended for use in residential environments and may not provide adequate radio reception protection in such environments.
Korea (KCC) Class A equipment (industrial broadcasting and communications equipment)
Class A: This equipment meets the requirements for industrial electromagnetic wave equipment and the seller or user should be aware of this. This equipment is intended for use in a commercial environment, not a home environment.
United States (FCC) 47 CFR 15 Subpart B. This product is considered to be exempt equipment under Section 15.103.
safety
General Information IEC 61010-1, contamination class 2
surveying IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
radio
Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
Radio frequency range 2400 MHz to 2483.5 MHz
output power <100 mW
Simplified EU Declaration of Conformity
Fluke hereby declares that the radio equipment contained in this product complies with Directive 2014/53/EU.
To view the full EU Declaration of Conformity, please visit the following URL:
www.fluke.com/en-us/declaration-of-conformity

Model: 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe

393 FC
393 FC CAT III 1500 V True-rms Clamp Meter with iFlex Probe

Included:

  • Fluke 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex Probe
  • Test Leads, CAT III 1500 V Safety Rating, Right Angle Plugs, Caps
  • iFlex 18-inch Flexible Current Probe
  • TPAK Magnetic Tape
  • Quality suitcase
  • Backed by a 3-year warranty

Fluke 393 FC | Technical Information [login to download and view]

F393-393FC User's Manual [please login to download and view]

Expand More
Fluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex ProbeFluke 393 FC CAT III 1500 V True RMS Clamp Meter with iFlex Probe

Click to enquire

Product consultation and purchase:18218718851

I already understand