Product Overview: T6-600 Non-Contact Voltage and Current Tester
From now on, say goodbye to the pen, AC current/voltage measurement, a "clamp" can be two.
The Fluke T6, with its innovative FieldSense technology, can simultaneously measure AC voltage and current* through the jaws without the need for the meter to touch a metal contact! (T6-600 requires key switching to display current/voltage readings)
Particularly suitable for residential, CBD, supermarkets and other property staff daily quick inspection. Daily inspection without having to carry a clamp meter, multimeter and other pieces of instrumentation, a T6 easily complete the routine work.
The small 17.8mm open jaws are designed to handle tight measuring spaces or dense wiring.
FieldSense technology brings non-contact jaw measurement voltage way, no need to strip the wire or open the metal electrocution protection mechanism, can be carried out through the jaws without (table) "pen" fast voltage measurement of the new experience, and further isolate the potential risk of electrocution operations. Suitable for maximum 120 square cables detection, is 200 kilowatts (200KW) and the following motors, low-voltage motors, low-voltage distribution cabinets, the ideal fast inspection tool.
* Only: single phase wire (not applicable to double or multi-stranded wires containing zero/ground etc.), operating frequency 45~66HZ, AC voltage above 16V.
+ Voltage measurements require grounding through the black pen for more accurate readings [± (3 % + 3 counts)]. Actual readings may vary depending on actual grounding conditions.
Product Specification: T6-600 Non-Contact Voltage and Current Tester
| Measurement specifications | ||||
| functionality | need Test Leads |
range (of scales or measuring equipment) | resolution (of a photo) | accurate[1] |
| FieldSense AC Voltage True RMS |
not have | 600 V | 1 V | ± (3% + 3 counts) 45 Hz - 66 Hz[2][3] |
| FieldSense AC Current True RMS |
not have | 200.0 A | 0.1 A | ±(3% + 3 ) 45 Hz - 66 Hz |
| AC Voltage True RMS | be | 600 V | 1 V | ±(1.5% + 2 ) 45 Hz - 66 Hz |
| dc voltage | be | 600 V | 1 V | ±(1% + 2) |
| resistive | be | 2000 Ω | 1 Ω | ±(1% + 2) |
| security level | 600 V CAT III | |||
| accurate [1]: ± ([% of reading] + [lowest RMS digit]). Accuracy applies for one year after calibration at operating temperatures from 18 °C to 28 °C (64 °F to 82 °F) and relative humidity to 90 %. AC Measurements: AC coupled, RMS response. accurate [2]: Add 3 % without an external ground connection. External grounding requires the user to wear insulated gloves, stand on an insulated ladder, or otherwise be insulated from the ground. accurate [3]: FieldSense can be specified from 16 V to full scale. |
||||
| General technical indicators | ||||
| calibrations | 1 year calibration cycle | |||
| sizes | 61.1 x 259.3 x 43.8 mm | |||
| Jaw Opening | 17.8 mm | |||
| weights | 0.35 kg (0.78 lb) | |||
| temp Work: Storage: |
-10 °C to +50 °C (14 °F to 122 °F) |
|||
| humidity level Work: Storage: |
2,000 meters (6,562 feet) |
|||
| relative humidity | 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) 0% through 75%, 30 °C through 40 °C (86 °F through 104 °F) 0% through 45%, 40 °C through 50 °C (104 °F through 122 °F) |
|||
| Battery type and life time | Two AA type alkaline batteries (IEC LR6); 360 hours standard battery life; 200 hours battery life (with FieldSense) | |||
| temperature coefficient | 0.1 x (specified accuracy) / °C (28 °C) ( 82.4 °F) |
|||
| security level | IEC/EN 61010-1: Contamination class 2 | |||
| electromagnetic environment | IEC/EN 61326-1: Portability | |||
Model: T6-600 Non-Contact Voltage and Current Tester
T6-600 Non-Contact Voltage Test Clamp Meter
Fluke T6-600 Electrical Tester
- Quick Reference Guide
- warranty card
- grip
- writing brush
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.