:: Rich basic functionality
● Easily handle difficult measuring areas, moving objects or locations where there is a risk of electric shock
:: Pistol-type, clear display
Laser Product Cautionary Tips
A tip label is attached to the outside of the thermometer. Please use it according to the contents of the label.
-

The basic use of infrared thermometer
The process of infrared thermometer laser calibration and emissivity from setup to measurement is explained. An infrared thermometer can be used to easily measure the temperature of air conditioning vents at higher elevations, circuit breakers that touch dangerous electrical cabinets, or running motors.
-
There are 2 types of infrared thermometers available for different temperature measurement locations
FT3700: for long focal lengths and large temperature ranges
FT3701: for long focal lengths, small ranges and precise temperature measurements
A 2-point infrared thermometer with infrared calibration capable of accurately locating temperature measurement sites. -
Pistol-type infrared thermometer that can measure easily with one touch of a button
Simply press the measurement trigger, simple and easy
Holds the measured value when released -
Because it is an infrared thermometer, it is easy to measure even dangerous and inaccessible places.
Untouchable sites in operation
Locations where there is a risk of electric shock
Inaccessible sites
Suitable for temperature measurement in any location.
Basic parameters
| FT3700-20 | FT3701-20 | |
|---|---|---|
| Test Range | -60.0~550.0℃, resolution: 0.1℃ | -60.0 ~ 760.0℃, Resolution: 0.1℃ |
| Test Accuracy | -35.0 to -0.1°C: ±10 %rdg. ±2°C 0.0 to 100.0°C: ±2°C 100.1 to 500.0°C: ±2 % rdg. ※ -60.0 ~ -35.1℃, 500.1℃~ : No accuracy specification |
|
| response time | 1 second (90% response) | |
| test wavelength | 8 to 14 μm | |
| Emissivity Compensation | ε = 0.10 to 1.00 (0.01 step) | |
| Test Field of View | The distance of 1m is φ83mm ※Distance D: Field of view S=12:1 |
The distance of 3m is φ100mm ※Distance D: Field of view S=30:1 |
| fig. aim (for a higher standard) | 2-Point IR Laser Positioning (Class 2, 1mW max), Red | |
| functionality | Maximum/minimum/difference between maximum and minimum/average measurement, upper and lower limit alarm function, continuous measurement mode, automatic power saving, backlighting | |
| power supply | Alkaline 7 batteries × 2, continuous use: approx. 140 hours (with laser positioning, backlight and buzzer off) | |
| Volume and weight | 48W×172H×119Dmm,256g(including battery) | |
| attachment (email) | Instruction manual, carrying case, No. 7 alkaline battery (LR03) × 2 | |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.