TH2836 is a new generation of impedance testing instrument developed successfully by adopting the current international advanced auto-balancing bridge principle, with the basic accuracy of 0.05%, the fastest testing speed of 5.6ms, and the frequency range of 4Hz-8.5MHz. The four-end pair port configuration can effectively eliminate the influence of electromagnetic coupling of the test line, and the lower limit of low impedance testing capability has been expanded ten times downward than the conventional five-end configuration instrument.

Categories. , Tags. , , Brand.

Inquire about this product

■ TH2836 is a new generation of impedance test instrument developed successfully by adopting the current international advanced auto-balancing bridge principle, with the basic accuracy of 0.05%, the fastest test speed of 5.6ms, and the frequency range of 4Hz-8.5MHz. The four-end pair port configuration can effectively eliminate the influence of electromagnetic coupling of the test line, and the lower limit of low impedance testing capability has been expanded ten times downward than the conventional five-end configuration instrument.

The TH2836 supports high power test conditions with 2V AC test signals and 10V DC bias, and the enhanced multi-parameter list scanning/multi-parameter graphical analysis capability will help users to expand their ability to fully evaluate components.

The TH2836 is a powerful tool for electronic component design, inspection, quality control and production testing. Its excellent performance and functionality provide a powerful tool for circuit design and development as well as research and development of materials (electronic and non-electronic).

1679464221486775

A. High precision

The auto-balanced bridge ensures higher frequency accuracy over a wider frequency range than ordinary LCR bridges!

image.png

B. High stability and consistency                                                                                                                C. High speed

1689558895447530                                       1689558909131113

D. Functions and Interfaces

1679464389113371                                               1679464403133811

Single Test Display List Scan Display

E. Material dielectric constant test

TH2836 series with the special material test fixture TH26077 and the host computer software can easily and accurately measure the dielectric constant of materials at different frequencies.

1679464502125893                        1679464510771387

F. Upper computer software

1). Generalized host computer software

Test approach:

1679464555117821                   1679464562667250               1679464575124620

Single List Scan

File Save:

1679464648994937                 1679464660121745                        1679464673910294

Save format Single autosave List autosave results

Hardware connection: RS232C, USB, GPIB, LAN

Data image saving format: TXT, XLS, MDB, CSV, BMP, JPG, PNG

Other functions: automatic recording, setting file saving, user management, etc.

2). Piezoelectric ceramics host computer software

Analyze the settings:

167946496773119616794649721747951679464977402605167946499511371116794650026044671679465006682527

Analyze the results:

1679465700337713          1679465707632308

Main Parameter Chart Primary and Secondary Parameters (Conducting Circle)

G. Optional accessories

1679465859622842

Product Model TH2836
demonstrate 7-inch TFTLCD display 800 x RGB x 480
AC Measurement Parameters Cp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, Vac, Iac
DC measurement parameters Rdc, Vdc, Idc
Test Frequency realm 4Hz-8.5MHz
highest resolution 1mHz
test level AC Voltage 4Hz-1MHz: 5mV-2Vrms

1MHz-8.5MHz: 5mV-1Vrms

resolution (of a photo) 100μV
AC current 4Hz-2MHz: 50μA-20mArms

2MHz-8.5MHz: 50μA-10mArms

resolution (of a photo) 1μA
DC voltage 100mV-2V
resolution (of a photo) 100μV
DC Bias input voltage 0V-±10V
Voltage Resolution 100μV
amps 0mA-±100mA
Current Resolution 1μA
Test Side Configuration four-pronged attack (e.g. marriage)
Cable length 0, 1 meter
Output Impedance 100Ω
Typical measurement time (speed) Fast: 5.6ms Medium: 120ms Slow: 230ms
Maximum accuracy 1kHz : 0.05% 1MHz : 0.05%

2MHz: 0.1%

5MHz: 0.5%

8.5MHz: 1.0%

Measurement display range a: 1 x 10-18(b); E: 1 x 1018
Cs, Cp ±1.00000aF-999.999EF
Ls, Lp ±1.000000aH-999.999EH
D ±0.00001-9.99999
Q ±0.01-99999.9
r, rs, rp, x, z, rdc ±1.00000aΩ- 999.999EΩ
G,B,Y ±1.00000aS - 99.9999ES
Vdc ±1.000000aV - 999.9999EV
Idc ±1.00000aA - 999.999EA
θr ±1.00000rad - 3.14159rad
θd ±0.0001deg - 180.000deg
Δ% ±0.0001% - 999.999%
Multi-function parameter list scanning 10 points, scanning parameters: measurement parameters, test frequency, AC voltage, AC current, DCBIAS voltage, DCBIAS current
graphical analysis Selection of the upper computer software
connector USB HOST, USB DEVICE, HANDLER, RS232C Option: GPIB
Power-on warm-up time 60 minutes.
Input Voltage 100-120VAC/198-242VAC selectable, 47-63Hz
power wastage 80VA
Dimensions (WxHxD) mm3 400x132x425
weights Approx. 15kg

■ Test frequency: 4Hz-8.5MHz

■ Test accuracy: 0.05%

■ High speed: up to 5.6ms test speed

■ High resolution: 7 inches, 800 x 480 resolution

■ 10-point multi-parameter list scanning function

■ Mathematical arithmetic functions

■ Automatic polarity function for varactor diodes

■ One-click screenshot function

■ One-touch recording function

■ 10-speed sorting function, sorting results sound and light alarms

■ Extra large storage space:

Built-in: 40 sets of setting files

Expansion: 500 sets of setting files, image files, and data logging files can be stored via USB memory.

■ High compatibility: supports SCPI instruction set, compatible with KEYSIGHTE4980A, E4980AL, HP4284A

■ Passive components:

Evaluation of impedance parameters and performance analysis of capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip assemblies, and network components.

■ Semiconductor components:

Test and analysis of parasitic parameters of LED driver integrated circuits; C-V of varactor diodesDCCharacterization; Parasitic parameter analysis of transistors or integrated circuits

■ Other components:

Impedance evaluation of printed circuit boards, relays, switches, cables, batteries, etc.

■ Medium material:

Evaluation of dielectric constants and loss angles of plastics, ceramics and other materials

■ Magnetic materials:

Evaluation of permeability and loss angle of ferrites, amorphous and other magnetic materials

■ Semiconductor materials:

Dielectric constant, conductivity and C-V properties of semiconductor materialsLiquid crystal materials: C-V properties of liquid crystal units such as dielectric constant and elasticity constant

standard equipment
Accessory Name model number
Boxed Four-Ended Insulated Locking Kelvin Test Leads TH26011BS
short circuit board TH26010
fixture (machining) TH26048

 

optional
Accessory Name model number
Magnetic Ring Clamp (Piece Type) TH26007A
Magnetic Ring Fixture TH26008A
Patch Test Leads with Boxes TH26009B
fixture (machining) TH26047
Test Fixture TH26062
Test Fixture TH26063
High Frequency Patch Fixture TH26108C
Dielectric Test Fixture TH26077
fixture (machining) TH26048B
Expand More
TH2836 High Frequency LCR Digital BridgeTH2836 High Frequency LCR Digital Bridge

Click to enquire

Product consultation and purchase:18218718851

I already understand