Product Overview: Fluke 375 FC True Root Mean Square AC/DC Clamp Meter
The Fluke 375 FC is part of the Fluke Connect Wireless Test Tools product family. Now you can:
- Recording and trending of measured values to accurately identify intermittent faults
- Wireless transmission of results via the Fluke Connect® Measurements application
- Create and issue reports on site
- Connects to Apple and Android devices via Bluetooth to stay safe from arc-flash areas
The Fluke 375 FC is a direct replacement for the Fluke 375 clamp meter.
Product Specifications: Fluke 375 FC True Root Mean Square AC/DC Clamp Meter
| General technical specifications | ||
| AC current through the clamp | ||
| range (of scales or measuring equipment) | 600.0 A | |
| resolution (of a photo) | 0.1 A | |
| precision | 2% ± 5 bits (10 Hz to 100 Hz) | |
| 2.5% ±5 bits (100-500 Hz) | ||
| Crest Factor (50 Hz/60 Hz) | 3 (at 500 A) | |
| 2.5 (at 600 A) | ||
| 2% increased at C.F. > 2 | ||
| AC current through flexible current probe | ||
| range (of scales or measuring equipment) | 2500 A | |
| resolution (of a photo) | 0.1 A (≤ 600 A) | |
| 1 A (≤ 2500 A) | ||
| precision | 3% ±5 bits (5 - 500 Hz) | |
| Crest Factor (50/60Hz) | 3.0 (at 1100 A) | |
| 2.5 (at 1400 A) | ||
| 1.42 (at 2500 A) | ||
| 2% increased at C.F. > 2 | ||
| position sensitivity | ||
![]() |
||
| i2500-10 Flex | i2500-18 Flex | |
| A | ||
| optimal distance | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| inaccuracies | ±0.5 % | ±0.5 % |
| B | ||
| optimal distance | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| inaccuracies | ±1.0 % | ±1.0 % |
| C | ||
| optimal distance | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| inaccuracies | ±2.0 % | ±2.0 % |
| The main conductor in the middle of the measurement uncertainty determination is in an optimal position, free of external electric or magnetic fields and within the operating temperature range. | ||
| direct current | ||
| range (of scales or measuring equipment) | 600.0 A | |
| resolution (of a photo) | 0.1 A | |
| precision | 2% ± 5 bits | |
| alternating current | ||
| range (of scales or measuring equipment) | 1000 V | |
| resolution (of a photo) | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| precision | 1.5% ± 5 bits (20 Hz to 500 Hz) | |
| dc voltage | ||
| range (of scales or measuring equipment) | 1000 V | |
| resolution (of a photo) | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| precision | 1% ± 5 bits | |
| millivolt DC | ||
| range (of scales or measuring equipment) | 500.0 mV | |
| resolution (of a photo) | 0.1 mV | |
| precision | 1% ± 5 bits | |
| Frequency (via clamp) | ||
| range (of scales or measuring equipment) | 5.0 Hz to 500.0 Hz | |
| resolution (of a photo) | 0.1 Hz | |
| precision | 0.5% ± 5 bits | |
| trigger level | 5 Hz to 10 Hz, ≥10 A | |
| 10 Hz to 100 Hz, ≥5 A | ||
| Frequency (via flexible current probe) | ||
| range (of scales or measuring equipment) | 5.0 Hz to 500.0 Hz | |
| resolution (of a photo) | 0.1 Hz | |
| precision | 0.5% ± 5 bits | |
| trigger level | 5 Hz to 20 Hz, ≥25 A | |
| 20 Hz to 100 Hz, ≥20 A | ||
| 100 Hz to 500 Hz, ≥25 A | ||
| resistive | ||
| range (of scales or measuring equipment) | 60 kΩ | |
| resolution (of a photo) | 0.1 Ω (≤600 Ω) | |
| 1 Ω (≤6000 Ω) | ||
| 10 Ω (≤60 kΩ) | ||
| precision | 1% ± 5 bits | |
| capacitors | ||
| range (of scales or measuring equipment) | 1000 μF | |
| resolution (of a photo) | 0.1 μF (≤ 100 μF) | |
| 1 μ F (≤ 1000 μF) | ||
| precision | 1% ± 4 bits | |
| Mechanical specifications | ||
| Maximum voltage between any terminal and ground | 1000 V | |
| batteries | 2 AA, NEDA 15A, IEC LR6 | |
| operating temperature | -10 °C to +50 °C | |
| storage temperature | -40 °C to +60 °C | |
| Operating humidity - Non-condensing (< 10 °C) |
≤90% RH (10 °C to 30 °C) | |
| ≤75% RH (30 °C to 40 °C) | ||
| Working altitude | 3000 m | |
| Storage altitude | 12000 m | |
| Dimensions (L x W x H) | 249 x 85 x 45 mm | |
| weights | 395 g | |
| Jaw Opening | 34 mm | |
| Flexible Current Probe Diameter | 7.5 mm | |
| Flexible Current Probe Cable Length (end to wire connector) |
1.8 m | |
| safety | IEC 61010-1, contamination class 2 | |
| IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | ||
| IP Protection Rating | IEC 60529: IP30 without operation | |
| Radio Frequency Certification FCC ID | T68-FBLE IC: 6627A-FBLE | |
| Electromagnetic Compatibility (EMC) | ||
| international standard | IEC 61326-1: Portable, electromagnetic environment, IEC 61326-2-2 | |
| CISPR 11: Group 1, category A | ||
| Group 1: Equipment intentionally generating and/or using on-coupled RF energy, which is necessary for the internal operation of the equipment itself. | ||
| Class A: The instruments are intended for use in non-domestic use and in any equipment not directly connected to the low voltage network supplying residential buildings. Due to conducted and radiated interference, it may be difficult to ensure electromagnetic compatibility in other environments. The radiation generated by this equipment when connected to the test object may exceed the levels specified in CISPR 11. | ||
| Korea (KCC) | Class A equipment (industrial broadcasting and communications equipment) | |
| Class A: This product complies with the requirements for industrial electromagnetic wave equipment and the seller or user should be aware of this. This equipment is intended for use in a commercial environment and not in a home environment. | ||
| United States (FCC) | 47 CFR 15 Subpart B. This product is exempt equipment under Section 15.103. | |
| temperature coefficient | 0.1 times the specified accuracy per degree Celsius above 28 °C or below 18 °C | |
Model: Fluke 375 FC True Root Mean Square AC/DC Clamp Meter
Fluke 375 FC
Fluke 375 FC True Root Mean Square AC/DC Clamp Meter
Included:
- Soft Carrying Case
- TL75 Test Leads
- 2 AA alkaline batteries
- Plasticized instruction card
- Safety Information Sheet
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.