Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter
Fluke 17B MAX Digital Multimeter

Fluke 17B MAX Digital Multimeter

¥9,999.00
  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Main characteristics

  • Misuse audible and visual alarms to reduce fuse damage
  • 1mm Extra Tip Pen for Circuit Board Testing
  • Wake up at any key to improve efficiency
  • Voltage: 6000 word reading
  • Capacitance range: 2000uF
  • CATIII 600V safety rating
  • Supports frequency and temperature measurements

Product Overview: Fluke 17B MAX Digital Multimeter

The 17B MAX is an upgraded replacement model for the 17B+, which has been discontinued. The new multimeter has been upgraded with the following six features:

  • New - Misoperation audible and visual alarms to avoid blowing fuses
  • New - Standard with two pairs of regular & extra sharp pens for more scenarios (KIT model)
  • New - Arbitrary key wake-up to improve testing efficiency
  • NEW - Voltage readings upgraded to 6000 words
  • New - Capacitance range upgraded to 2mF
  • Added - Beeps increased
Fluke_CN_POLOs_parameter_comparison_990x855_v2

Misoperation audible and visual alarms Input Alert™

  • Improve efficiency: Reduce the efficiency of field testing caused by misuse by frontline staff, and even safety accidents;
  • Cost Savings: Fewer fuses to replace;
  • Alarm effect by flashing lights in noisy and dark environments.
Misoperation sound and light alarm

1mm Extra Tip Pen

  • During board testing, the 1mm tip can accurately test to the device pins to avoid short circuits;
  • The diameter of the meter pen is 20% thinner than the ordinary meter pen, which can be leaned closer to meet the needs of testing in a narrow space;
  • Selected nib material, sturdy and durable, the meter pen has been rigorously tested, the nib is not easy to bend;
  • The pen cap has a protective and anti-loss design;
  • Only 02 and KIT models come standard with an extra-tip pen.
15B-17B-MAX-1mm

Wake up with any key

  • No need to turn the knob to OFF to activate a dormant meter, making testing more efficient;
  • Avoid dialing back into the wrong gear.
Wake up with any key

Product Specification: Fluke 17B MAX Digital Multimeter

technical specification
Accuracy is applicable for one year after calibration at operating temperatures from 18 °C to 28 °C and relative humidity from 0 % to 75 %. Accuracy specifications take the following form: ± ([% of reading] + [least significant digit word value]).
functionality range (of scales or measuring equipment) resolution (of a photo) accurate
15B MAX 17B MAX
AC voltage (40 Hz to 500 Hz)1 6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3 1.0 % + 3
AC Voltage (mV) 600.0 mV 0.1 mV 3.0 % + 3 3.0 % + 3
dc voltage 6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3 0.5 % + 3
DC voltage (mV) 600.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10
AC current μA (40 Hz to 400 Hz)2 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3 1.5 % + 3
AC current mA (40 Hz to 400 Hz) 2 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3 1.5 % + 3
AC current A (40 Hz to 400 Hz)2 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3
DC current μA 2 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3 1.5 % + 3
DC current mA 2 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3 1.5 % + 3
DC current A 2 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3
Diode Testing 3 2.000 V 0.001 V 10% 10%
Temperature 4 50.0 °C to 400.0 °C
0 °C to 50.0 °C
-55.0 °C to 0 °C
0.1 °C inapplicable 2 %+1 °C
2 °C
9 %+2 °C
Resistance (ohms) 5 400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
capacitors6 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
2000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
frequency1(10 Hz to 100 kHz) 50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
inapplicable 0.1 % + 3
duty cycle1 1% to 99% 0.10% inapplicable 1 % Typical situation7
Throughput Threshold - - 70Ω 70Ω
backlight - - there are there are
1 All AC currents, frequencies, and duty cycles are specified from 1 % to 100 % of range. Input values below 1 % of range are not specified. 
2 Typical load voltage DC/AC current µA: 100 µV / µA, DC/AC current mA: 2 mV/mA, DC/AC current A: 0.03 V/A 
3 Typically, the open-circuit test voltage is 2.0 V and the short-circuit current <0.6 mA. 
44 Type K thermocouple support 
5 5 Typical open-circuit test voltage 0.54 V, maximum short-circuit current 1.8 mA 
6Specifications do not include errors due to test lead capacitance and capacitive substrate (which can be as high as 1.5 nF in the 40 nF range). 
7 Typical is a frequency of 50 Hz or 60 Hz and a duty cycle of 10 % to 90 %.
Input Characteristics
functionality overload protection Input Impedance (nominal) Common mode rejection ratio Conventional mode rejection ratio
alternating current 1000 V 1 >10 MΩ, <100 pF Greater than 60 dB at 50 Hz or 60 Hz -
AC Voltage (mV) 1000 V 1 >1 MΩ, <100 pF Greater than 80 dB at 50 Hz or 60 Hz -
dc voltage 1000 V 1 >10 MΩ, <100 pF More than 100 dB at 50 Hz or 60 Hz Greater than 60 dB at 50 Hz or 60 Hz
DC voltage (mV) 1000 V 1 >1 MΩ, <100 pF Greater than 80 dB at 50 Hz or 60 Hz -
1106 V Hz (maximum)
General technical indicators
Maximum voltage between any terminal and ground 600 V
Maximum differential voltage between V terminal and COM terminal 1000V
Display (LCD) 6000 counts, updated 3 times per second
Battery Type 2 AA, IEC LR6
Battery life Minimum 500 hours
temp Operating temperature: 0 °C to 40 °C;
Storage temperature: -30 °C to 60 °C
relative humidity Operating humidity: ≤ 90 % relative humidity at 10 °C to 30 °C; ≤ 75 % relative humidity at 30 °C to 40 °C; non-condensing (below 10 °C)
Operating Humidity, 40 MΩ Range Relative humidity ≤ 80 % at 10 °C to 30 °C; Relative humidity ≤ 70 % at 30 °C to 40 °C.
height above sea level Working altitude: 2000 m; storage: 12000 m
temperature coefficient 0.1 X (specified accuracy)/°C (28 °C)
Fuse protection for current input 440 mA, 1000 V fast-fusing, Fluke-specified parts only. 11 A, 1000 V Fast Fusing, Fluke Specified Parts Only
Volume (H x W x L) 183 mm x 91 mm x 49.5 mm
weights 455 g
IP rating IP40
safety IEC 61010-1, IEC 61010-2-030 CAT III 600 V, pollution class 2
electromagnetic environment IEC 61326-1: Portability
electromagnetic compatibility Only available in Korea

Class A equipment (industrial broadcasting and communications equipment) 1
11This product complies with the requirements for industrial (Class A) electromagnetic wave equipment, and the seller or user should be aware of this. This equipment is intended for use in a work environment, not a home environment.

Model: Fluke 17B MAX Digital Multimeter

Fluke 17B MAX-01 Digital Multimeter
  • TL75 Test Lancet with Two Protective Caps
  • Type K Thermocouple Temperature Probes
  • 2 AA batteries
  • user manual
Fluke 17B MAX-02 Digital Multimeter
  • TL31 Extra Tip Pen with Two Protective Caps
  • Type K Thermocouple Temperature Probes
  • user manual
Fluke 17B MAX KIT Digital Multimeter
  • TL75 Test Lancet with Two Protective Caps
  • TL31 Extra Tip Pen with Two Protective Caps
  • Type K Thermocouple Temperature Probes
  • 2 AA batteries
  • user manual

Fluke 17B MAX Digital Multimeter | Datasheet [Login to download and view]

15B MAX / 17B MAX | User's Manual [Please login to download and view].

Expand More
Fluke 17B MAX Digital MultimeterFluke 17B MAX Digital Multimeter
¥9,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand