-Integrates power supply, electronic load, DMM functions
-12 channels/unit, simulates cell action for each channel
-Large module environments up to 1000V in series can be built.
-Two quadrant output voltage, battery balanced at -1A~1A
-High-precision voltage output, high-precision voltage/current measurement
Measurement of small currents (BMS dark current, cell balancing circuit leakage current) in the -100μA range
Basic parameters (accuracy guaranteed for 1 year, adjusted accuracy guaranteed for 1 year)
| channel number | 12ch |
|---|---|
| Maximum series connection | Maximum series output voltage not exceeding 1000V Can be connected in series with the main unit |
| Output range | DC voltage: 0.0000 V ~ 5.0250 V (all channels independent) Maximum output current: ±1.00000 A (all channels independent) |
| Test Range | DC voltage: -0.00100 V ~ 5.10000 V DC current (2 ranges): ±1.20000 A (1 A range), ±120.0000 μA (100 μA range) |
| Points time | 1PLC (20 ms at 50 Hz, 16.7 ms at 60 Hz) × number of smoothing settings |
| Voltage output accuracy | ±0.0150% of setting ±500 μV |
| Voltage measurement accuracy | ±0.0100% of reading ±100 μV |
| Current measurement accuracy | 1A range: ±0.0700% of reading ±100 μA 100μA range: ±0.0350% of reading ±10 nA |
| connector | LAN |
| power supply | Wide power supply (AC 100 V ~ 240 V), 50 Hz/60 Hz |
| Volume and weight | 430W × 132H × 483D mm, 10.3 kg |
| attachment (email) | Instruction manual × 1, power cord × 1, rack frame × 1, PC application CD-ROM × 1 (application range Refer to software parameters) |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.