-All voltages, currents, powers, harmonics, flicker, etc. are measured simultaneously in time sequence (flicker function in Ver.UP)
-Trend recording while capturing all power anomalies such as instantaneous blackouts, voltage drops, frequency changes, etc.
-Easy to follow measurement steps with QUICK SET function
-Accessory application PQ ONE produces GB-compliant reports.
-Record waveforms up to 1 second before and 10 seconds after the event.
-Measures DC current accurately over long periods of time (using AC/DC auto-zeroing current sensors)
-Current sensor power supply from PQ3100 main unit
Current and power measurements require the purchase of a separate current sensor. More favorable kits are available than buying separately.
Basic parameters (1 year accuracy guarantee, 1 year accuracy guarantee after adjustment)
| Measuring Lines | In addition to single-phase 2-wire/single-phase 3-wire/three-phase 3-wire/three-phase 4-wire, voltage/current measurements can also be made using ch4 (all channels correspond to AC/DC measurements). |
|---|---|
| Voltage range | Voltage measurement 1000.0 Vrms or DC, transient measurement 2.200 kVpeak |
| Current range | AC/DC 50.000 mA to 5.0000 kA (varies depending on the measurement range of the sensor used) |
| power range | 50.000 W to 6.0000 MW (automatically determined by the current range and wiring used) |
| Basic precision | Voltage: ±0.2% of nominal voltage, Current: ±0.1% rdg. ±0.1% f.s. + Current Sensor Accuracy, Active Power: DC ±0.5% rdg. ±0.5% f.s. + Current Sensor Accuracy AC ±0.2% rdg. ±0.1% f.s. + Current Sensor Accuracy |
| measurement function | 1. Transient overvoltage: 200 kHz sampling 2. Frequency 1 waveform: operation from 1 waveform 3. Voltage 1/2 RMS, Current 1/2 RMS: 1 waveform operation per separated half wave half 4. Surges, sags, brownouts: detected at 1/2 RMS voltage 5. Inrush current: Detected at the RMS value after each half-wave operation current. 6. Frequency 200 ms: from 10 waveforms - 12 waveforms for operation 7. Frequency 10 seconds: operation from waveforms in 10-second intervals 8. Voltage waveform peaks, current waveform peaks 9. Voltage, current, active power, apparent power, reactive power, active energy, apparent energy, reactive energy, electricity cost, power factor, displacement power factor, voltage unbalance ratio, current unbalance ratio 10. Voltage crest factor, current crest factor 11. Harmonics/phase angle (voltage/current), harmonic power: 0th to 50th 12. Harmonic voltage-current phase difference: 1st to 50th 13. Total harmonic distortion rate (voltage/current) 14. Interharmonics (voltage/current): 0.5th to 49.5th 15. K-factor (multiplier) 16. (Ver.UP) Transient flash value: Conforms to IEC 61000-4-15. 17. (Ver.UP) ΔV10 flicker, IEC flicker (short/long) |
| Maximum recording time | Maximum 1 year, maximum recording time: 9999 items × 365 days |
| connector | SD/SDHC memory card, RS-232C, LAN (HTTP server function), USB 2.0 |
| demonstrate | 6.5-inch TFT color LCD (640 × 480 dots) |
| power supply | AC Adapter Z1002 (100 to 240 V, rated 1.7 A, 50/60 Hz) Battery pack Z1003 (8 hours of continuous use, AC adapter connection for charging, charging time 5 hours 30 minutes) |
| Volume and weight | 300W × 211H × 68D mm, 2.5 kg (with battery pack Z1003) |
| attachment (email) | Instruction manual ×1, Measurement guide ×1, Voltage cable L1000-05 ×1 (Red, yellow, blue, gray, black, Alligator clips ×5, Spiral tube ×5), Colored spiral tubes (for distinguishing the color of the clamp sensor) ×Set of colored spiral tubes, Spiral tubes ×5, AC adapter Z1002 ×1, Carrying strap ×1, USB connecting cable (1 m) ×1, Battery pack Z1003 ×1, PQ ONE (software) CD) ×1 |