Metal non-contact power measurement! No danger of short circuit
Metal non-contact power measurement Single-phase to three-phase 4-wire, up to 400V wires Measures leakage currents from a minimum of 50.000mA (sensor option required) Long-term data storage to SD card Setup wizard feature helps with proper wiring

Categories. , Tag. Brand.

Inquire about this product

● New harmonic measurement function up to 13th.
● Voltage measurement directly on the wire without risk of short circuit
Ideal for measuring power and confirming energy savings in buildings and offices.
:: Single-phase to three-phase 4-wire, 400V max. wires
● Measurement of leakage currents down to a minimum range of 50.000 mA (sensor option required)
:: Data can be stored on SD cards for long periods of time
● Setup wizard function to facilitate proper wiring (graphical wizard screen with clear indication of connection status)

Note: The PW3365-30 main unit cannot measure current and power separately. Please purchase the optional clamp-on current sensor separately according to the purpose of measurement. In addition, please be sure to purchase and use the optional SD card in order to ensure that the measurement data can be saved.

Basic parameters

Measuring Lines
(Number of measurable circuits)
50/60 Hz, single-phase 2-wire (1 circuit/2 circuits/3 circuits), single-phase 3-wire (1 circuit), three-phase 3-wire/three-phase 4-wire (1 circuit), current 1~3CH only
Measurement items Voltage/current true rms, voltage/current fundamental, voltage/current fundamental phase angle, frequency, voltage waveform peak value (absolute), current waveform peak value (absolute)
Active/reactive/apparent power, power factor (lagging-over) or displacement power factor (lagging-over) active (consumption-regeneration)/reactive power (lagging-over), active (consumption-regeneration)/reactive power electricity (lagging-over), active (consumption-regeneration)/reactive power electricity value (lagging-over), power factor electricity, electricity cost display
harmonic (wave with frequency an integer multiple of the fundamental) Harmonic voltage, harmonic current, total harmonic distortion rate (THD-F or THD-R) for voltage, total harmonic distortion rate (THD-F or THD-R) for current, up to the 13th order
Voltage range AC 400 V
Current range AC 500.00 mA~5.0000 kA (Measuring range varies depending on the sensor used), AC 50.000 mA~5.0000 A Leakage current only)
power range 200.00 W~6.0000 MW (depending on the combination of voltage/current range and measurement line)
Basic precision Voltage : ±1.5% rdg. ±0.2% f.s (PW3365+PW9020 combination accuracy)
Current : ±0.3% rdg. ±0.1% f.s. + Current Sensor Accuracy
Power : ±2.0% rdg. ±0.3% f.s. + current sensor accuracy (power factor = 1)
Display update rate Approx. 0.5 s (except for SD card/internal memory and LAN-USB communication)
Data logging Real-time saving in SD card, memory
Save Interval 1~30 seconds, 1~60 minutes, 14 steps switching
Saving items Measured value saving: average only / average-max-min
Screen copy: BMP format (can be saved every 5 minutes at the shortest interval)
Waveform saving: binary format (can be saved at minimum intervals of 1 minute)
connector SD memory card
LAN 100BASE-TX: HTTP server function, setup via communication application software - data downloading
USB2.0: Recognizes SD memory cards and memory as removable storage devices when connected to a computer, setup by communication application software - data downloads
functionality Wiring confirmation, setting navigation, clock, etc.
power supply AC Adapter Z1008 (100V~240V, 50/60Hz), 45VA (with AC adapter)
Battery pack 9459: (Maximum rated power 5VA, 6 hours and 10 minutes charging by connecting AC adapter), Continuous use time 3h (Backlight OFF)
Volume and weight 180 W × 100 H × 48 D mm, 540 g (without PW9002 installed)
180 W × 100 H × 67.2 D mm, 820 g (with PW9002 mounted)
attachment (email) Voltage sensor PW9020 ×4, AC adapter Z1008 ×1, USB cable (0.9 m) ×1, Instruction manual ×1, Measurement guide ×1, Colored spiral tubes (4 each of red, blue, and yellow) ×1 set, Spiral tubes ×10 (for bundling the connection cable)

Voltage Sensor PW9020 Basic Specifications

Measurable conductor types Sheathed wires (equivalent to IV, CV), metal partially shielded wires are not allowed. Multi-core wires and wires with thicker jackets may not be measured accurately.
Measurable conductor diameter Finished shape: φ 6 mm ~ φ 30 mm
IV Wire : 8 mm^2 ~ 325 mm^2
CV wire : 2 mm^2 ~ 250 mm^2
Measurable range 90 V ~ 520 V
thread length Approx. 3.0 m (relay box in the middle of the wire)