Product Features
♦ Adopting third generation SiC technology with dual capability of Souce and Sink
High power density, up to 18kW in 3U, expandable to 2MW in parallel
Voltage output range: 0 to 2250V
Current output range: 0 to 2040A (single cabinet), 0 to 8000A (parallel connection between cabinets)
♦ Bidirectional energy transfer, seamless switching across quadrants
♦ Can be used for battery cycle test, support CC/CV/CP and other battery charging and discharging modes.
♦ Can be used as a PV simulator (with SAS1000 software), supporting the simulation of solar cell matrix I-V curves.
It can be used as a battery simulator (with BSS2000 software) to simulate the characteristic curve of LiFePO4/LiT3 battery.
♦ Built-in USB/CAN/LAN/Digital IO interface, optional GPIB/Analog & RS232
♦ Multiple protection functions, support OVP, ± OCP, ± OPP, OTP, power-down, islanding protection
♦ Built-in LV123, LV148, DIN40839, ISO-16750-2, SAEJ1113-11, LV124 and ISO21848 standard voltage curves for automotive power grids
♦ Built-in function generator, support arbitrary waveform generation
♦ Support control loop priority mode setting, set different loop speeds
Adjustable output impedance
Product Features and Benefits
Seamless transfer of energy in both directions
The IT6000C series is a bi-directional programmable DC power supply based on the third generation SiC technology. Unlike traditional power supplies and loads that have short jumps and discontinuities when switching between positive and negative currents, the IT6000C series, as a standard high-speed bi-directional power supply, can realize high-speed switching between source and load current modes, resulting in fast, continuous and seamless switching between output and absorption currents, effectively avoiding overshooting of the voltage or current, and is widely used in the testing of energy storage devices such as batteries, battery packages, and battery protection boards. It is widely used for battery, battery package, and battery protection board testing.
High energy recovery efficiency
The IT6000C series bi-directional programmable DC power supply has an energy recovery function, which can recover electrical energy and then directly utilize it in the plant instead of consuming it in the form of heat energy. Its conversion efficiency can reach 95%, which not only greatly reduces the user's electricity costs, but also avoids the use of air-conditioning or expensive refrigeration systems and reduces noise.
Solar cell array simulation
The IT6000C series is equipped with SAS1000 solar cell matrix simulation software, which can simulate the I-V curve of the solar cell matrix, with built-in SAS models of EN50530, Sandia, NB/T32004, CGC/GF004, CGC/GF035, and the user can simulate the output of the I-V curve and generate a report by simple parameterization, which can be used to test the static and dynamic maximum power tracking efficiency of the PV inverter. The user can simply set the parameters to simulate the I-V curve output and generate reports for testing the static and dynamic maximum power tracking efficiency of PV inverters. Users can also edit any shielded I-V curve up to 4096 points to realize the dynamic cloud cover effect, or store 100 I-V curves under different light and temperature in the memory, and set the execution time and sequence of each curve to test the long time maximum power tracking performance of the PV inverters under different climate conditions.
model number | input voltage | amps | power (output) | resolution (of a photo) | Precision | Connector | sizes |
---|---|---|---|---|---|---|---|
IT6005C-80-150 | 80V | 150A | 5kW | 0.001V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6010C-80-300 | 80V | 300A | 10kW | 0.001V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6015C-80-450 | 80V | 450A | 15kW | 0.001V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6030C-80-900 | 80V | 900A | 30kW | 0.001V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 6U |
IT6045C-80-1350 | 80V | 1350A | 45kW | 0.001V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6060C-80-1800 | 80V | 1800A | 60kW | 0.001V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6075C-80-2040 | 80V | 2040A | 75kW | 0.001V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6090C-80-2040 | 80V | 2040A | 90kW | 0.001V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6105C-80-2040 | 80V | 2040A | 105kW | 0.001V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6120C-80-2040 | 80V | 2040A | 120kW | 0.001V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6006C-300-75 | 300V | 75A | 6KW | 0.01V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6012C-300-150 | 300V | 150A | 12KW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6018C-300-225 | 300V | 225A | 18KW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6036C-300-450 | 300V | 450A | 36kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 6U |
IT6054C-300-675 | 300V | 675A | 54kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6072C-300-900 | 300V | 900A | 72kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6090C-300-1125 | 300V | 1125A | 90kW | 0.01V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6108C-300-1350 | 300V | 1350A | 108kW | 0.01V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6126C-300-1575 | 300V | 1575A | 126kW | 0.01V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6144C-300-1800 | 300V | 1800A | 144kW | 0.01V/0.1A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6006C-500-40 | 500V | 40A | 6kW | 0.01V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6012C-500-80 | 500V | 80A | 12kW | 0.01V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6018C-500-120 | 500V | 120A | 18kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6036C-500-240 | 500V | 240A | 36kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 6U |
IT6054C-500-360 | 500V | 360A | 54kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6072C-500-480 | 500V | 480A | 72kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6090C-500-600 | 500V | 600A | 90kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6108C-500-720 | 500V | 720A | 108kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6126C-500-840 | 500V | 840A | 126kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6144C-500-960 | 500V | 960A | 144kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6006C-800-25 | 800V | 25A | 6kW | 0.01V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6012C-800-50 | 800V | 50A | 12kW | 0.01V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6018C-800-75 | 800V | 75A | 18kW | 0.01V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6036C-800-150 | 800V | 150A | 36kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 6U |
IT6054C-800-225 | 800V | 225A | 54kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6072C-800-300 | 800V | 300A | 72kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6090C-800-375 | 800V | 375A | 90kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6108C-800-450 | 800V | 450A | 108kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6126C-800-525 | 800V | 525A | 126kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6144C-800-600 | 800V | 600A | 144kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6018C-1500-40 | 1500V | 40A | 18kW | 0.1V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6036C-1500-80 | 1500V | 80A | 36kW | 0.1V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 6U |
IT6054C-1500-120 | 1500V | 120A | 54kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6072C-1500-160 | 1500V | 160A | 72kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6090C-1500-200 | 1500V | 200A | 90kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6108C-1500-240 | 1500V | 240A | 108kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6126C-1500-280 | 1500V | 280A | 126kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6144C-1500-320 | 1500V | 320A | 144kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6018C-2250-25 | 2250V | 25A | 18kW | 0.1V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 3U |
IT6036C-2250-50 | 2250V | 50A | 36kW | 0.1V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 6U |
IT6054C-2250-75 | 2250V | 75A | 54kW | 0.1V/0.001A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6072C-2250-100 | 2250V | 125A | 72kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 15U |
IT6090C-2250-125 | 2250V | 150A | 90kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6108C-2250-150 | 2250V | 175A | 108kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6126C-2250-175 | 2250V | 200A | 126kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |
IT6144C-2250-200 | 2250V | 225A | 144kW | 0.01V/0.01A | ≤0.02%+0.02%FS/≤0.1%+0.1%FS | USB/CAN/LAN/Digital I/O ports, optional GPIB/Analog & RS232 | 27U |