Product Overview: Fluke 289 True RMS Industrial Recording Multimeter
Being aware of what is going on and preventing what is going on.
Industrial meters for demanding users.
New diagnostic features to maximize plant productivity. The Fluke 289 is a new generation of high-performance industrial logging multi-meters that make it easy to solve complex problems in electronics, factory automation, power distribution, and electrical engineering equipment. The ability to record data and view it graphically on the screen makes it easy for users to quickly solve problems and helps minimize downtime.
| Product Main Features |
|
|---|---|
| Benefits for users |
|
Product Specifications: Fluke 289 True RMS Industrial Recording Multimeter
| Technical indicators | ||
| functionality | ||
| dc voltage | Range/Resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic precision | 0.025% | |
| alternating current | Range/Resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic precision | 0.4% (true RMS) | |
| direct current | Range/Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic precision | 0.05% | |
| alternating current (electricity) | Range/Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic precision | 0.6% (true RMS) | |
| Temperature (without probe) | Range/Resolution | -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
| Basic precision | 1.0% | |
| resistive | Range/Resolution | 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
| Basic precision | 0.05% | |
| capacitors | Range/Resolution | 1.000 nF, 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100 mF |
| Basic precision | 1.0% | |
| frequency | Range/Resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
| Basic precision | 0.005% | |
| connectivity | Optional Fluke ir3000 FC Infrared Connector | |
| General technical indicators | ||
| Maximum voltage between any terminal and ground | 1000 V | |
| Battery Type | 6 AA alkaline batteries, IECLR6 | |
| Battery life | 100 hours minimum, 200 hours in logging mode | |
| temp | operating temperature | -20 °C to 55 °C |
| Storage temperature | -40 °C to 60 °C | |
| relative humidity | 0 to 90% (0 to 37 °C), 0 to 65% (37 °C to 45 °C), 0 to 45% (45 °C to 55 °C) | |
| electromagnetic compatibility | EMC EN61326-1 | |
| vibratory | MIL-PRF-28800F Class 2 Random Vibration | |
| impingement | 1 meter drop test according to IEC 61010-1 3rd edition | |
| Dimensions (H x W x D) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
| weights | 870.9 g (28 oz) | |
| The screen displays multiple sets of data | there are | |
| True RMS AC Bandwidth | 100 kHz | |
| dBV/dBm | there are | |
| DC mV Resolution | 1 μV | |
| megohm range | Up to 500 MΩ | |
| conductivity | 50.00 nS | |
| On-off test buzzer | there are | |
| Battery/fuse check port | Yes/Yes | |
| time clock | there are | |
| calendar clock | there are | |
| Minimum value - Maximum value - Average value | there are | |
| duty cycle | there are | |
| pulse width | there are | |
| Isolated Fiber Optic Interface | there are | |
| Auto/Touch Hold | there are | |
| readout memory | there are | |
| Login to PC | there are | |
| Interval/event logging | there are | |
| logging memory | Up to 15000 readings | |
| Wireless connection (optional) | there are | |
Model: Fluke 289 True RMS Industrial Recording Multimeter
Fluke 289
True RMS Electronic Recording Multimeter with Trend Capture Function
All models are included:
- 6 AA batteries, installed
- TL71 Silicone Test Leads
- Probe Sleeves
- Two alligator clips
Supplementary material:
- registration card
- Calibration documentation
- Getting Started Manual
- Calibration Certification Form
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.