● Corresponds to wireless! Data transmission with smartphones and tablet devices is possible (with optional wireless adapter Z3210).
● Measured values are transmitted wirelessly and directly into Excel® sheets (with optional wireless adapter Z3210).
:: Newly designed sensors can correctly check leakage current (up to φ40 mm diameter).
● Measurement from leakage current to load current.
● Conforms to the performance criteria specified in the international leakage current clamp standard IEC / EN 61557-13.
:: Responding to leakage faults -- insulation management
:: Comparison function enables shortening of testing time.
CAT Ⅳ 300 V
CAT III 600 V
CAT III 600 V
Basic parameters (accuracy guaranteed for 1 year, adjusted accuracy guaranteed for 1 year)
| AC current range | 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, true RMS rectified Basic Accuracy 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA ~ 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Basic accuracy 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt Accuracy specification range 0.060 mA to 200.0 A |
|---|---|
| AC Voltage Range | not have |
| frequency range | 15.0 Hz to 2000 Hz |
| crest factor | 3 (outside 200.0 A range), 1.5 (200.0 A range) |
| filtration function | Cutoff frequency at ON 180 Hz ±30 Hz (-3 dB) |
| output function | not have |
| harmonic (wave with frequency an integer multiple of the fundamental) | Harmonic level/content/total harmonic distortion up to the 30th order in the current can be measured [when Z3210 is installed]. * :: Can be displayed using application software (GENNECT Cross) |
| Other Functions | Maximum / Minimum / Average / Peak Maximum / Peak Minimum display, Display value Hold, Auto Hold, Background light, Auto power saving function, Beeper, Number of events display, Comparator, Simple event log, Inrush current test |
| demonstrate | Display update rate: 5 times/second |
| power supply | Alkaline Battery No. 5 (LR6) × 2, Continuous use time: 48 h (without Z3210), 30 h (wireless communication when used with Z3210) |
| Measurable conductor diameter | φ40 mm or less |
| Dimensions/Weight | 64W × 233H × 37D mm, 400 g |
| attachment (email) | Case C0203 ×1, Instruction manual ×1, Precautions for use ×1, Alkaline battery No. 5 (LR6) ×2 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.