● Automatic judgment of AC and DC
● Up to DC 2000V for open-circuit voltage checking of photovoltaic panels (when using P2000)
● Simultaneous display of inrush current (INRUSH) RMS value and waveform peak value
● Wireless support! Measured values can be transferred to a smartphone or tablet device (when wireless adapter Z3210 is installed)
● Measurement data is transferred directly to a table created using Excel® (when the wireless adapter Z3210 is installed)
● Harmonic analysis from the 1st to 30th order is possible with the software GENNECT Cross (when the wireless adapter Z3210 is installed)
CAT IV 600 V, CAT III 1000 V
(CAT III 2000 V, CAT IV 1000 V (when using P2000)
Basic parameters (accuracy guaranteed for 1 year, adjusted accuracy guaranteed for 1 year)
| DC current range | 600.0 A/2000 A, basic accuracy: ±1.3% rdg. ±0.3 A (range 600A) |
|---|---|
| AC current range | 600.0 A/2000 A (10 Hz to 1 kHz, true RMS rectified), basic accuracy 45 - 66 Hz : ±1.3% rdg. ±0.3 A (at 600A) |
| crest factor | Range 600.0 A: 3 or less Range 2000.0 A: 2.84 or less |
| AC + DC current range | 600.0 A/2000 A (10 Hz ~ 1 kHz, true RMS rectified), basic accuracy DC, 45 - 66 Hz : ±1.3% rdg. ±1.3 A (at 600A) |
| DC voltage range | 600.0 mV to 1000 V (600.0 V to 2000 V when using P2000) |
| AC Voltage Range | 6.000 V to 1000 V, 4 ranges (15 to 1 kHz, true RMS rectification), basic accuracy 45 - 66 Hz : ±0.9% rdg. ±0.003 V (at 6V) |
| AC + DC voltage range | 6.000 V to 1000 V, 4 ranges, basic accuracy DC, 45 - 66 Hz : ±1.0% rdg. ±0.013 V (at 6V) |
| Resistance range | 600.0 Ω to 6.000 MΩ, 5 ranges, basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω) |
| electrostatic capacitance range | 1.000 μF to 1000 μF, 4 ranges, basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF) |
| frequency range | 9.999 Hz to 999.9 Hz, 3 ranges, basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz) |
| Temperature (K) | -40.0 to 400.0 ˚C, Accuracy: ±0.5% rdg. ±3.0 ˚C + Temperature Probe Accuracy |
| a power test | Hi: AC40 V~600 V, Lo: AC80 V~600 V, 50/60 Hz |
| harmonic (wave with frequency an integer multiple of the fundamental) | Harmonic level/content/total harmonic distortion up to the 30th order in the current can be measured [when Z3210 is installed]. * :: Can be displayed using application software (GENNECT Cross) |
| Other Functions | DC power, conductivity check, diode check, AC/DC auto judgement function, DC current-voltage positive/negative judgement function, maximum/minimum/average/peak maximum/peak minimum display, low-pass filtering function, display value hold, backlight, auto power save, beep, zero adjustment, etc. |
| Dust and water resistance | IP20 (voltage measurement in completely dry condition, with jaws closed) IP54 (when stored) |
| power supply | Alkaline Battery No. 7 (LR03) × 2 Approx. 40h (when Z3210 is not installed), approx. 24h (when Z3210 is installed and communicating wirelessly) Other conditions: AC 100 A measurement, LCD backlight OFF, 23°C reference value |
| Measurable conductor diameter | Φ55 mm, Jaw size: 92 W × 18 D mm |
| Volume and weight | 65 W × 250 H × 35 D mm, 530 g |
| attachment (email) | Test Lead L9300 ×1, Carrying Case C0203 ×1, Alkaline Battery No. 7 (LR03) ×2, Instruction Manual ×2, Precautions for Use ×1 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.