TH8400 series is a high-precision, high-intelligence, easy-to-operate DC electronic load. This series of instruments collects a variety of test functions, superior performance, and the use of LCD screen display, display clear, operation menuization, fast and convenient, can be well adapted to the production site rapid operation needs and laboratory high accuracy and high stability needs.

Categories. , Tags. , , Brand.

Inquire about this product

TH8400 series is a high-precision, high-intelligence, easy-to-operate DC electronic load. This series of instruments collects a variety of test functions, superior performance, and the use of LCD screen display, display clear, operation menuization, fast and convenient, can be well adapted to the production site rapid operation needs and laboratory high accuracy and high stability needs.

The TH8400 series programmable DC electronic loads include the following types:

model number input voltage amps power (output)
TH8401 150V 30A 175W
TH8402A 150V 30A 350W
TH8402 150V 60A 350W
TH8403 150V 120A 1000W
TH8404 150V 180A 1500W
TH8405 150V 240A 2000W
TH8411 500V 15A 175W
TH8412 500V 30A 350W

 

Functional Features

Conventional mode (4 types)

CC Constant current mode

An electronic load always draws a constant current, regardless of whether the voltage changes.

1650088653244678-1

CR Constant Resistance Mode

An electronic load is equivalent to a constant resistance, and the load changes current linearly with voltage.

1650088660513799-1

CV Constant Voltage Mode

The electronic load controls the voltage output from the power supply by adjusting the pull current according to the set voltage value.

image.png

CP Constant Power Mode

An electronic load is equivalent to a constant resistance, and the load changes current linearly with voltage.

1650088674736661-2

Advanced modes (12)

DYN Dynamic Load Mode

A dynamic test frequency of up to 25kHz can be used to test the dynamic characteristics of a power supply over a wide bandwidth, with two current levels that can be set, the duration of each of the two current levels, the rising slope, the falling slope, and the number of repetitions. This function can be used to test the instantaneous high current tolerance of D/D converters and batteries.

1650088683462204-2

1650088688506527-2

SWP Dynamic Frequency Sweep Mode

The electronic load provides a programmable dynamic frequency sweep to invert the frequency to find the worst case voltage of the object to be measured. Dynamic Frequency Sweep requires the setting of two current levels, start frequency, end frequency, step frequency, duration, rise slope, and fall slope. During operation, the electronic load will pull current at the set frequency for the set duration. Frequencies up to 25kHz are used to capture the worst case Vp+, Vp- and corresponding Fp+, Fp- of the power supply under test.

1650088695771516-2

CR-LED Analog LED Test Mode

By setting the on-state voltage and resistance of the light-emitting diode, it can realistically simulate the actual load characteristics of the LED, avoiding the oscillations generated by the unstable voltage and current under the conventional constant resistance mode (CR), and thus detecting the real load conditions of the LED power supply.

1650088702640958-3

BATT Battery Test Mode

Load test battery performance, discharge conditions support CC, CR and CP three ways, by setting voltage, time, current capacity or power capacity of four conditions to let the electronic load to stop pulling load, to ensure that the battery will not be over-discharged and damaged.

image.png

Load Effect Test

The load will be carried under low quasi-pull current (Imin), high quasi-pull current (Imax) and normal operating current (Inormal) for a preset period of time (Delay), and then the voltage values under different loads will be recorded to measure and display the Load Adjustment Ratio (Regulation), ΔV, and Power Supply Internal Resistance (Rs) of the power supply under test.

image.png

TIME Time measurement mode

Measures the time from the start of the trigger condition to the end of the trigger condition in the range of 0s to 100000s. Can be used for battery charging and discharging tests and other similar applications.

 

OVPT Overvoltage Protection Test Mode

The load captures the peak and falling edge of the input voltage and triggers at the preset level (Vtrig) at the time of the falling edge, then this voltage peak is the overvoltage protection point of the power supply under test, and the time interval between the peak moment and the trigger moment is the OVP response time of the power supply under test (Tovp), and the accuracy of Tovp measurement is 2us.

 

OCPT Overcurrent Protection Test Mode

The electronic load pulls a step-up current to test whether the output voltage of the power supply is lower than the trigger voltage under overload conditions, and then determine whether the output protection function of the power supply is normal.

image.png

OPPT Over Power Protection Test Mode

The electronic load pulls the load step-up power to test whether the output voltage of the power supply is lower than the trigger voltage under overload conditions, and then determine whether the output protection function of the power supply is normal.

image.png

LIST List Test Mode

The LIST mode can accurately complete complex arbitrary current change patterns at high speeds, accomplishing precision testing of multiple quasi-positional current carry loads. Multiple complex sequences are generated by editing the pull-load value, duration, slope, and repetition times for each step to meet complex testing needs.

It is mainly applied to simulate battery discharge pull current, laptop pull current, electric vehicle pull current, and dynamic current above two current levels.

1650088733499642-1

AUTO Automatic Test Mode

The AUTO mode can accurately simulate the automatic test process of the production line and complete the multi-step precision test, which can help customers to save cost greatly. Different modes can be set for each step, and by editing the pull-load value, duration, rising slope, falling slope, and the upper and lower limits of current, voltage and power for each step, you can judge whether each step is qualified or not.

 

B. Programmable rate of change of loading current

The user can set the rate of change during current loading according to the application. If the rate is set, the rate will take effect in the following cases.

◎ When changing the set value to change the current value (including various advanced functions).

◎ When there is a change due to the loading current value.

1650088742122076-1

C. Programmable soft start function

The soft start function can be used to set the rise time of the load current. The start-up time is continuously adjustable between 10μs and 500ms.

This function can be used to prevent the output of the DUT from becoming unstable due to a sharp rise in load current, or to avoid a delayed start of the power supply due to overcurrent protection.

1650088751105488-11650088754187962-1

D. Short-circuit function

Independent short-circuit test function supports short-circuit test in any function mode, realizing seamless connection with other functions. When the instrument enters the short-circuit test, the instrument is loaded at the maximum current of the current range.

model number TH8401 TH8402A TH8402 TH8403 TH8404 TH8405 TH8411 TH8412
Rated parameters power (output) 175W 350W 350W 1000W 1500W 2000W 175W 350W
input voltage 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~50V 0~500V 0~50V 0~500V
amps 0~3A 0~30A 0~3A 0~30A 0~6A 0~60A 0~12A 0~120A 0~18A 0~180A 0~24A 0~240A 0~1.5A 0~15A 0~3A 0~30A
Minimum operating voltage 1.5V@30A 1.2V@30A 1.5V@60A 1.5V@120A 1.5V@180A 1.5V@240A 3V@15A 3V@30A
Minimum Rise Time 20μS
CV mode realm 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~50V 0~500V 0~50V 0~500V
resolution (of a photo) 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV
accurate 0.05% + 0.05%FS
CC mode realm 0~3A 0~30A 0~3A 0~30A 0~6A 0~60A 0~12A 0~120A 0~18A 0~180A 0~24A 0~240A 0~1.5A 0~15A 0~3A 0~30A
resolution (of a photo) 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1 mA 0.1mA 1mA 0.1mA 1mA
accurate 0.05% + 0.05%FS
CR mode realm 0.05Ω~50kΩ 0.05Ω~50kΩ 0.05Ω~25kΩ 0.02Ω~50kΩ 0.02Ω~50kΩ 0.01Ω~25kΩ 0.2Ω~50kΩ 0.1Ω~50kΩ
resolution (of a photo) 0.05Ω 0.05Ω 0.1Ω
accurate 1% 1%
CP mode realm 0~175W 0~350W 0~350W 0~1000W 0~1500W 0~2000W 0~175W 0~350w
resolution (of a photo) 10mW 10mW 10mW 100mW 100mW 10mW 10mW 10mW
accurate 0.5% + 0.1%FS
dynamic mode realm 20μs ~ 60S
resolution (of a photo) 2μs
accurate 2uS+100ppm
rate of increase 0.6A/ms~1.5A/ µS 0.6A/ms~1.5A/ µS 1.2A/ms~3A/µS 2.4A/ms~6A/µS 3.6A/ms~9A/µS 4.8A/ms~12A/µS 0.3A/ms~0.75A/ µs 0.6A/ms~1.5A/µs
Voltage measurement realm 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~50V 0~500V 0~50V 0~500V
resolution (of a photo) 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV
accurate 0.08% + 0.05%FS
Current Measurement realm 0~3A 0~30A 0~3A 0~30A 0~6A 0~60A 0~12A 0~120A 0~18A 0~180A 0~24A 0~240A 0~1.5A 0~15A 0~3A 0~30A
resolution (of a photo) 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA
accurate 0.08% + 0.05%FS
Ripple Measurement realm 0~15V 0~150V 0~15V 150V 0~15V 150V 0~15V 0~150V 0~15V 0~150V 0~15V 0~150V 0~50V 0~500V 0~50V 0~500V
bandwidths 250kHZ
accurate 0.1%
protective function Over Voltage Protection (OVP) Over Current Protection (OCP) Over Power Protection (OPP)
save Internal 40 groups
norm
Volume (mm)

(W*H*D)

215 x 88 x 390 Shelf volume: 215×88×390

External volume: 236×111×454

430mm*88mm*529mm  

Shelf volume: 215×88×390

External volume: 236×111×454

weights 3kg 4.8kg 4.8kg 13kg 15.5kg 18kg 3kg 4.8kg
power supply Power supply voltage: 220V(1±10%), power supply frequency: 50Hz/60Hz(1±5%), power consumption: <50VA
Temperature and humidity 0°C to 40°C, Humidity: < 90%RH

■ Input: 175W (150V/30A)

 

■ 1mV/0.1mA high resolution

■ Dynamic frequencies up to 25 kHz

■ Sampling speed up to 500kHz

■ Low ripple and low noise

■ Voltage/current ripple, peak, peak-valley measurements

■ Voltage/current waveform display

A collection of more than a dozen operating and measuring functions

■ 4.3-inch 24-color 480X272 TFT LCD screen, Chinese and English interface

■ Numeric keypad and knob operation

■ Screen copy function

■ Data logging function

■ Remote compensation function

■ Intelligent Fan Control

■ Protection modes: over-voltage, over-current, over-power

■ Support U disk file storage loading, program upgrading

▪ Software control and testing via computer

■ HANDLER interface for easy automation matching

■ SCPI command protocol

■ power supply category

Charger, switching power supply, communication power supply, LED driver, cell phone battery, rechargeable treasure, etc.

■ new energy

Solar Cells, New Power Vehicles, Electric Bicycles

■ Electronic Power Components

Fuses / Connectors / Relays / Sensors

■ Automation equipment integration testing

standard equipment
Accessory Name model number
Test Leads at Both Ends TH26004C

 

optional
Accessory Name model number
Expand More
TH8401 Programmable DC Electronic LoadTH8401 Programmable DC Electronic Load

Click to enquire

Product consultation and purchase:18218718851

I already understand