TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer
TH2829C Automatic Component Analyzer

TH2829C Automatic Component Analyzer

TH2829 series automatic component analyzer applies high-speed processor and new software system, which gives it higher test speed, more comprehensive analysis functions and friendly human-machine interaction experience. The well-designed measurement circuit and optimized algorithm further enhance the test stability of low D-value capacitors and high Q-value inductors. The 10V AC test level, 10V/100mA bias power supply and independent 10V/50mA DC power supply provided by the instrument make it more convenient to apply the instrument to the testing of various passive/active devices. Dual primary and secondary parameter displays, enhanced display system design, up to 201-point list scanning, and graphical analysis capability for a wide range of parameters enable the instrument to meet the most demanding user applications.

Categories. , Tags. , , Brand.

Inquire about this product

With strong impedance test technology and rich R&D experience, Tonghui keeps launching new impedance test products --- TH2829 series automatic component analyzer is another masterpiece newly launched by our company.

TH2829 series automatic component analyzer applies high-speed processor and new software system, which gives it higher test speed, more comprehensive analysis functions and friendly human-machine interaction experience. The well-designed measurement circuit and optimized algorithm further enhance the test stability of low D-value capacitors and high Q-value inductors. The 10V AC test level, 10V/100mA bias power supply and independent 10V/50mA DC power supply provided by the instrument make it more convenient to apply the instrument to the testing of various passive/active devices. Dual primary and secondary parameter displays, enhanced display system design, up to 201-point list scanning, and graphical analysis capability for a wide range of parameters enable the instrument to meet the most demanding user applications.

Thanks to the application of new generation processor, the instrument has more powerful data processing capability, and the test results can be conveniently stored in the U disk or uploaded to the upper PC or network through a variety of interfaces, to promote the test automation and improve the test efficiency. This series of test frequency up to: 20Hz-1MHz, with a test accuracy of 0.05%, the highest test speed of 9ms / times. The instrument is equipped with HANDLER, USB, LAN, RS232C, DCI, GPIB (optional) and other rich interfaces, all show the rich resources, will bring customers a better cost-effective experience.

The TH2829 series of component analyzers are perfectly suited to the test requirements of a wide range of industrial and military standards.

1601172241281686-1

 

Functional Features

A. Simultaneous measurement and display of multiple parameters

The TH2829 series digital bridge can simultaneously measure four parameters of the impedance element in one test cycle, including two main parameters and two subparameters, and display the test values of the four parameters in the same interface at the same time.

1601172336113879-11601172371991194-1

 

 

B. High stability and consistency

1641367209133927

C. High speed

1601172513324889-1

 

D. Functions and interfaces

1601172591344254-1

1601172636687690-1

E. Material dielectric constant testing

Together with the special material test fixture TH26077 and the software of the upper computer, it can easily and accurately measure the dielectric constant of materials at different frequencies.

1601172759740275-1

F. Optional accessories

1601172830667422-1

1601172923492713-1

A. Host computer software

a) Generic host computer software

Test approach:

1601173015131944

File Save:

1601173068911068

Hardware connection: RS232C, USB, GPIB, LAN

Data image saving format: TXT, XLS, MDB, CSV, BMP, JPG, PNG

Other functions: automatic recording, setting file saving, user management, etc.

 

b) Piezoelectric ceramics host computer software

Analyze the settings:

1601173481271487

Analyze the results:

1601173623337283-1

model number TH2829A TH2829C
monitor (computer) 800×RGB×480 7-inch TFT LCD monitor
test signal frequency 20Hz-300kHz 20Hz-1MHz
minimum resolution 1mHz, 5-bit frequency input
accuracy 0.01%
AC level Test Signal Voltage Range 5mV-10Vrms
Voltage Minimum Resolution 100μV, 3-bit input
accuracy ALC ON 10% x set voltage + 2mV
ALC OFF 6% x set voltage + 2mV
Test signal current range 50μA-100mA
Current Minimum Resolution 1μA, 3-bit input
accuracy ALC ON 10% x set current + 20μA
ALC OFF 6% x set voltage + 20μA
DC Bias Voltage Source Voltage / Current Range 0V- ±10V / 0mA-±100mA
resolution (of a photo) 0.5mV / 5μA
Voltage Accuracy 1% x set voltage + 5mV
ISO ON For inductor, transformer plus bias test
AC source internal resistance ISO ON 100Ω
ISO OFF 30Ω, 50Ω, 100Ω selectable
DCR Source Internal Resistance 30Ω, 50Ω, 100Ω selectable
DC Voltage Source Voltage / Current Range 0V- ±10V / 0mA-±50mA
resolution (of a photo) 1mV
Voltage Accuracy 1% x set voltage + 5mV
output resistance 100Ω
LCR Test Parameters |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc
Test page parameter display Two groups of primary and secondary parameters, the second group of parameters can be ON/OFF; a variety of parameters continuous scanning graphic analysis
Basic Measurement Accuracy LCR Test Parameters 0.05%
calibration condition Warm-up time: ≥30 minutes; Ambient temperature: 23±5oC; Signal voltage: 0.3Vrms-1Vrms; Clear "0": after OPEN, SHORT; Test cable length: 0 m
Measurement time (≥10 kHz) Fast: 9 ms/times Medium: 67 ms/times Slow: 187 ms/times plus display character refresh time
LCR parameter display range | z | , r , x , dcr 0.00001Ω - 99.9999MΩ
|Y|, G, B 0.00001μs - 99.9999s
C 0.00001pF - 9.99999F
L 0.00001μH - 99.9999kH
D 0.00001 - 9.99999
Q 0.00001 - 99999.9
θ (DEG) -179.999o - 179.999o
θ (RAD) -3.14159 - 3.14159
Δ% -999.999% - 999.999%
equivalent circuit Series, Parallel
Measurement range Automatic, Hold
trigger method Internal, Manual, External, Bus
Average number of times 1-256
calibration function Open Circuit, Short Circuit Full Frequency, Spot Frequency Calibration, Load Calibration
mathematical operation Direct reading, ΔABS, Δ%
Delay time setting 0 -- 999, minimum resolution 100us
 

Comparator Functions

 

10-speed binning, BIN1 to BIN9, NG, AUX
stall counting function
PASS, FAIL front panel LED display
List Scanning -Up to 201 point list scan with separate list scan tests for frequency, AC voltage/current, internal/external DC bias voltage/current, and independent DC source voltage. Each scan point can be sorted individually. The second scan parameter can be selected at the same time, but cannot be the same as the first scan parameter.
graphical analysis -Graphical scanning analysis of frequency, AC level, DC bias, etc. is available.

-Set the scanning start point, end point, and the number of points per scan.

-Display maximum and minimum values, and read the value of any selected scan point.

-Scanned graphics can be stored on the instrument's internal or external USB memory.

internal non-volatile memory 100 sets of LCRZ instrument setting file memory
External USB memory GIF image, CSV data file LCRZ instrument setting file memory test data USB memory direct storage
connector 1A bias current source 1A DC bias current source internally mountable (option)
I/O Interface HANDLER, output from the rear panel of the instrument
serial communications interface USB, RS232C
Parallel Communication Interface GPIB interface (option)
network interface LAN
memory interface USB HOST (front panel)
General technical parameters
Operating Temperature, Humidity 0℃-40℃, ≤ 90%RH
Power Requirements input voltage 99V-121V, 198V-242V AC
frequency 47Hz-63Hz
power wastage Maximum 80VA
Volume(W×H×D) 400mm × 132mm × 385mm
weights Approx. 13 kg

Basic accuracy factor curve:

image.png

Note: Test signal level: 0.3Vrms - 1Vrms

The upper values (those without parentheses) apply to medium and slow speeds, and the lower values (those in parentheses) apply to fast speeds.

■ Measurement frequency: 20Hz-1MHz, resolution: 1mHz

■ Basic accuracy: 0.05%

■ Test speed: 9ms/time

■ Impedance analysis and testing of piezoelectric ceramics, ultrasonic transducers and other devices

■ Continuous curve scanning/graphic analysis function

■ Simultaneous display of four measurement parameters

■ 800 x RGB x 480 7-inch TFT LCD monitor

■ Built-in 100 sets of LCRZ setting files

■ Direct storage of GIF images, CSV data files in USB memory

■ HANDLER, USB, LAN, RS232C, GPIB (optional) DCI interface

■ Signal source selection 10V/100mA programmable AC test level

■ 10V/100mA programmable DC bias power supply 10V/50mA standalone DC voltage source

■ 1A DC bias current source (optional) 120A external bias current source (optional)
■ Up to 201-point list scanning

■ Passive Components.

Evaluation of impedance parameters and performance analysis of capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip assemblies, and network components, etc.

■ Semiconductors.

Test and analysis of parasitic parameters of LED driver integrated circuits; C-VDC characteristics of varactor diodes; analysis of parasitic parameters of transistors or integrated circuits

■ Other components.

Impedance evaluation of printed circuit boards, relays, switches, cables, batteries, etc.

■ Media Material.

Evaluation of dielectric constants and loss angles of plastics, ceramics and other materials

■ Magnetic material.

Evaluation of permeability and loss angle of ferrites, amorphous and other magnetic materials

■ Semiconductor materials.

Dielectric constant, conductivity and C-V properties of semiconductor materialsLiquid crystal materials: C-V properties of liquid crystal units such as dielectric constant and elasticity constant

image.png

standard equipment
Accessory Name model number
fixture (machining) TH26048
short circuit board TH26010
Boxed Four-Ended Insulated Locking Kelvin Test Leads TH26011BS
Expand More
TH2829C Automatic Component AnalyzerTH2829C Automatic Component Analyzer

Click to enquire

Product consultation and purchase:18218718851

I already understand