brief introduction
ZC6061/ZC6062 series of standing microphone tester adopts advanced digital circuit design technology, mainly used in production line to measure the sensitivity of standing microphone at 100Hz, 1kHz, 5kHz frequency points, in order to be graded and matched according to the sensitivity detection. 100Hz, 1kHz and 5kHz signals are respectively indicated by three indicators, which can be indicated at the same time or separately. 100Hz and 5kHz can indicate both the sensitivity and their frequency response relative to 1kHz, when the frequency response exceeds the set value, there are sound and indicator alarm respectively. 100Hz and 5kHz can indicate both sensitivity and frequency response relative to 1kHz, when the frequency response exceeds the set value, there are sound and indicator alarm. The instrument is easy to operate, fast and accurate reading, high testing efficiency, but also has internal calibration, acoustic calibration function. Particularly suitable for resident microphone production line and telephone manufacturers outsourcing parts inspection, and has a HANDLER interface and RS-232 interface options, can be connected to the automatic test machine for rapid testing.
Performance Characteristics
- Unique digital circuit design technology
- Direct digital display of measured current, sensitivity and frequency response
- With sound and light alarm indication
- HANDLER, RS-232 interface options available
- 100Hz can be changed to 70Hz
Technical indicators
| model number | ZC6061 |
ZC6062 |
| Sensitivity test range | -26~-70dB (0dB=1V/Pa) Four ranges: -30dB, -40dB, -50dB, -60dB |
|
| Testing Accuracy | ±0.5dB | |
| Sensitivity Display | Digital display: 4-digit LED direct reading of dB number, resolution 0.1dB, reading updated 3 times per second; For 1kHz sensitivity, there is also an illuminated diode display with a programmable range: for 100Hz and 5kHz there is also an indication of their frequency response relative to 1kHz. |
|
| Operating Current Test Range | Digital display: 0-20mA | |
| warning indication | When the 100Hz and 5kHz frequency response exceeds the set value, respectively, the ascending limit and descending limit light-emitting diode indication and alarm sound, when the current exceeds the limit, the indicator light and alarm sound. | |
| test voltage | Five grades: ±1.5V, ±2V, ±3V, ±4.5V, ±6V Accuracy: ±3% Sex arbitrary selection |
|
| Test Signal Frequency | 100Hz, 1kHz, 5kHz | 100Hz, 1kHz |
| power supply | Power 2W, source sound pressure 94dB (0dB = 2 × 10-5Pa), 100Hz and 5kHz can be adjusted separately, can also be adjusted simultaneously | |
| load resistance | Five grades: 680Ω, 1kΩ, 1.5kΩ, 2kΩ, 2.2kΩ, 3kΩ, 10kΩ Accuracy: ±2% | |
| Electrical Calibration | 100Hz and 1kHz, 5kHz sine signal accuracy better than ±0.2dB | |
| power supply | Utility 220V±10%, 50Hz, power consumption about 20VA | |
| Continuous working time | Can be used continuously | |
| Overall dimensions | 350mm×340mm×125mm Sound source:φ108×98 | |
| connector | Handler, RS232 (option) | |
| weights | Approx. 5kg | |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.