DP-270 Active Differential Probe (1300V, 70MHz)
DP-270 Active Differential Probe (1300V, 70MHz)
DP-270 Active Differential Probe (1300V, 70MHz)
DP-270 Active Differential Probe (1300V, 70MHz)

DP-270 Active Differential Probe (1300V, 70MHz)

频率:70MHZ;最大测试电压:1300(Vp-p);衰减比例:X50/X500;精度:2%

SKU:DP-270 Categories. , Brand.

Inquire about this product

DP-270 Active Differential Probe (1300V, 70MHz)

model number DP-270
Bandwidth (-3dB) DC-70MHz
accurate ±2%
attenuation ratio X50/X500
rising time 5ns
Input Voltage Range (DC+ Peak AC) x50时≤±2600V(DC+ACpeak)

x500时≤±2600V(DC+ACpeak)

Maximum Input Voltage ±1300V (DC+ACpeak)
RMS 919Vrms
Input Impedance Between the two ends: 10MΩ//1pF

Single-ended to ground: 5MΩ//2pF

output voltage ≤±2.6V
Output Impedance 50Ω (in a 1MΩ input impedance oscilloscope system)
noise suppression ratio 60Hz:>80dB/100Hz:>60dB/1MHz:>50dB
5MHz restricted bandwidth Switchable: Full/5MHz
power supply Specify external 5V DC power supply
electricity consumption 00mA
operating temperature 0~50℃
Operating humidity 10~85%RH
weights 285g
Dimension(L×W×H) 175x68x28mm

DP-270尺寸图.jpg

The high frequency withstand curves are shown for the maximum common mode input voltage.

DP210中.jpg

DP210.jpg

Expand More
DP-270 Active Differential Probe (1300V, 70MHz)DP-270 Active Differential Probe (1300V, 70MHz)

Click to enquire

Product consultation and purchase:18218718851

I already understand