Product Overview: 8808A 5.5 Digit Multimeter
Exclusion of non-conforming products
The Fluke 8808A five-and-a-half digit multi-meter reliably performs common measurements in today's applications. Whether you're performing a functional test or a rigorous screening measurement, the 8808A's PASS/FAIL test function makes it easy to make a pass/fail determination by comparing the test to a set test limit. This is especially important in cases where results are critical. The 8808A's display clearly indicates a "pass/fail" test result. This feature eliminates the need for guesswork or estimation to make judgments during testing.
Improve quality and efficiency in R&D, manufacturing or maintenance
Product development, manufacturing, and repair service applications require a certain level of accuracy in addition to a more stable and reliable digital meter. 8808A stands up to any scrutiny. It offers AC and DC voltage, AC and DC current and resistance, and frequency measurements - all with good uncertainty, resolving power and reliable repeatability to meet the stringent requirements for measurement results.
Measure two parameters at once
The 8808A provides an excellent dual-test display function, allowing two different parameters of the same signal to be measured through a single test connection, such as measuring an AC voltage and displaying both the voltage value and the frequency at the same time. Two related parameters, such as voltage and current, can also be observed at the same time, which can reveal problems that are usually easy to ignore or implied, greatly simplifying the testing and troubleshooting process and improving efficiency.
Measurement of sensitive leakage currents
When conventional digital multi-meters measure small currents below 100 mA, the load effect of the meter itself loads the circuit under test. This makes measuring leakage current in battery-powered devices with the power off very difficult, and sometimes impossible.The Fluke 8808A is an instrument that utilizes a low-impedance I-V conversion technique for microcurrent measurements. In this special mode, the 8808A is able to measure small currents with a resolution of 1nA and without loading the circuit under test.
Performs 4-wire measurements using only two test leads
Fluke's 2x4 four-wire resistance feature utilizes a split jack that allows four-wire resistance measurements to be made using only two, rather than four, measurement wires. Surface-mounted components, which are widely used today, make it difficult to make connections for measurements. When making small precision resistance measurements with four wires, connections become very difficult. Fluke's 2x4 wire option connects four wires into two test pairs, making connections easy. Users enjoy the convenience and flexibility of four-wire measurements using only one pair of test wires while obtaining high resolution and uncertainty.
FlukeView® Forms Basic Edition
FlukeViewForms software enhances digital meters by recording, storing and analyzing individual readings or a series of measurements and then converting these into professionally formatted documents. Test data can also be transferred to a PC via the communications interface and readings can be displayed in tabular or graphical form using standard templates. To use more templates, or to customize templates using FlukeView® Forms Designer, purchase the FVF-UG upgrade to FlukeView® Forms 3.0.
Trust the quality of Fluke digital meters
The Fluke brand has always had a reputation for ruggedness, reliability, and accuracy. Thanks to our experience, design standards, and quality assurance programs, Fluke digital multimeters can stand up to any scrutiny of their specifications. In fact, Fluke digital multimeters typically outperform the specifications given. Ensure accurate measurements-reliable, repeatable, and confident!
Product Specifications: 8808A 5.5 Digit Multimeter
| Technical indicators | ||
| monitor | Vacuum Fluorescent Dot Matrix Multi-Segment Display | |
| resolution (of a photo) | 5 ½ bit | |
| dc voltage | Range: 200 mV to 1000 V range Maximum resolution: 1 uV Accuracy: 0.015 + 0.003 |
|
| alternating current | Range: 200 mV to 750 V range Maximum resolution: 1 uV Accuracy: 0.2 + 0.05 Frequency: 20 Hz to 100 KHz |
|
| resistive | 2x4 line: Yes Range: 200 Ω to 100 MΩ range Maximum resolution: 1 mΩ Accuracy: 0.02 + 0.003 |
|
| direct current | Range: 200 µA to 10 A range Maximum resolution: 1 nA Accuracy: 0.02 + 0.005 |
|
| alternating current (electricity) | Range: 20 mA to 10 A range Maximum resolution: 100 uA Accuracy: 0.3 + 0.06 Frequency: 20 Hz to 2 kHz |
|
| frequency | Range: 20 Hz to 1 MHz Maximum resolution: 10 mHz Accuracy: ± (0.01 % + 0.003% range) |
|
| algorithmic function | dB/dBm: yes | |
| Advanced Features | Limit comparison test with pass/fail indicator | |
| connector | RS-232, USB with optional adapter | |
| Programming Languages/Patterns | Simplified ASCII, Fluke 45 Remote Command Emulation | |
| universal norm | |
| weights | 2.1 kg (4.6 lbs) |
| Dimensions (H x W x D) | 88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in) |
| safety | Conforms to EN 61010-1:2001, ANSI/ISA 61010-1 (S82.02.01):2004, UL 61010-1:2004, AN/CSA C22.2 No. 61010.1:2004. |
Model: 8808A 5.5 Digit Multimeter
8808A
5 ½ digit multimeter, 0.01 %
Random Contains:
- hosts
- TL71 Test Leads
- power cable (of an appliance etc)
- USB to RS232 Interface Adapter Cable
- FlukeView Forms Basic Edition Software
- Calibration Statement
- WEEE Information Sheet
- Warranty statement
- Getting Started
- User's Manual CD-ROM (English)
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.