Fluke 712C RTD Calibrator
Fluke 712C RTD Calibrator
Fluke 712C RTD Calibrator
Fluke 712C RTD Calibrator
Fluke 712C RTD Calibrator
Fluke 712C RTD Calibrator
Fluke 712C RTD Calibrator
Fluke 712C RTD Calibrator

Fluke 712C RTD Calibrator

Main characteristics

  • The 712C is capable of measuring and simulating (13) different RTD types.
  • Measurement of a 4 to 20 mA signal while outputting a temperature signal source
  • Each unit comes with a specially designed hanger
  • Configurable 0% and 100% source settings for fast 25% linearity checks
  • Linear fading and 25% step auto-fade based on 0% and 100% settings
  • Dual inputs and backlit display for easy reading of measurement results
  • Automatically remembers the settings at power failure, making it easy to restart the test when power is turned on
  • 1-year and 2-year specifications with traceable calibration reports
  • 24V Volt Circuit Power

SKU:Fluke 712C Category. Brand.

Inquire about this product

Product Overview: Fluke 712C RTD Calibrator

The Fluke 712C RTD Temperature Calibrator is easy to use, highly accurate and single-function, making it a great test tool for temperature calibration professionals.

Product Specifications: Fluke 712C RTD Calibrator

General technical indicators
Maximum voltage applied between any terminal and ground or between any two terminals 30 V
operating temperature -10 °C to 50 °C
storage temperature -30 °C to 60 °C
Working altitude 2000 meters
Storage altitude 12,000 meters.
Relative humidity (relative operating humidity without condensation) non-condensing
90% (10 °C to 30 °C)
75% (30 °C to 40 °C)
45% (40 °C to 50 °C)
(non-condensing)
Vibration requirements MIL-T-28800E, Class 2
Drop test requirements 1 meter
protection class IEC 60529: IP52
electromagnetic environment IEC 61326-1: Portability
safety IEC 61010-1, max. 30 V grounding, contamination level 2
power supply 4 x 5 NEDA 15A IEC LR6 batteries
Dimensions (H x W x D) 52.5 mm x 84 mm x 188.5 mm
weights 515 g
DC mA Measurement
resolution (of a photo) 0.001 mA
range (of scales or measuring equipment) 0 to 24 mA
Accuracy (% of readings + counts) 0.010% + 2 μA
temperature coefficient ± (0.002 % of reading + 0.002 % of range)/°C (28 °C)
Ohm Measurement
Resistance range Accuracy (% of readings + counts)
0.00 Ω to 400.00 Ω 0.015% + 0.05 Ω
400.0 Ω to 4000.0 Ω 0.015% + 0.5 Ω
Note: Reading accuracy is based on 4-wire input. For 3-wire resistance measurements, add 0.05 Ω (0.00 Ω to 400.00 Ω), 0.2 Ω (400.0 Ω to 4000.0 Ω) to the specification, assuming all three wires are matched.
temperature coefficient ± (0.002 % of reading + 0.002 % of range)/°C (28 °C)
ohmic output
Resistance range 1.0 Ω to 400.0 Ω
1.00 Ω to 400.00 Ω
400.0 Ω to 1500.0 Ω
1500.0 Ω to 4000.0 Ω
Measurement of the excitation current of the device 0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Accuracy (% of readings + counts) 0.015% + 0.1 Ω
0.015% + 0.05 Ω
0.015% + 0.5 Ω
0.015% + 0.5 Ω
resolution (of a photo) 0.00 Ω to 400.00 Ω 0.01 Ω
400.0 Ω to 4000.0 Ω 0.1 Ω
temperature coefficient ± (0.002 % of reading + 0.002 % of range)/°C ( 28 °C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.
circuit power
open circuit voltage 24 V ±10%
Load Circuit Voltage 18 V minimum (at 20 mA current)
temperature coefficient ± (0.002 % of reading + 0.002 % of range)/°C ( 28 °C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.
RTD Inputs and Outputs
RTD type (α) Range (°C) Measurement (°C) Source (°C)
1 year 2 years Output Current 1 year 2 years
10Ω
Pt(385)
-200 to 100 °C 1.5 °C 3 °C 1 mA 1.5 °C 3 °C
100 to 800 °C 1.8 °C 3.6 °C 1 mA 1.8 °C 3.6 °C
50Ω
Pt(385)
-200 to 100 °C 0.4 °C 0.7 °C 1 mA 0.4 °C 0.7 °C
100 to 800 °C 0.5 °C 0.8 °C 1 mA 0.5 °C 0.8 °C
100 Ω
Pt(385)
-200 to 100 °C 0.2 °C 0.4 °C 1 mA 0.2 °C 0.4 °C
100 to 800 °C 0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03%
+0.36 °C
200 Ω
Pt(385)
-200 to 100 °C 0.2 °C 0.4 °C 500 μA 0.2 °C 0.4 °C
100 to 630 °C 0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03%
+0.36 °C
500 Ω
Pt(385)
-200 to 100 °C 0.3 °C 0.6 °C 250 μA 0.3 °C 0.6 °C
100 to 630 °C 0.015%
+0.28 °C
0.03%
+0.56 °C
0.015%
+0.28 °C
0.03%
+0.56 °C
1000 Ω
Pt(385)
-200 to 100 °C 0.2 °C 0.4 °C 250 μA 0.2 °C 0.4 °C
100 to 630 °C 0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03%
+0.36 °C
100 Ω
Pt(3916)
-200 to 100 °C 0.2 °C 0.4 °C 1 mA 0.2 °C 0.4 °C
100 to 630 °C 0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03%
+0.36 °C
100 Ω
Pt(3926)
-200 to 100 °C 0.2 °C 0.4 °C 1 mA 0.2 °C 0.4 °C
100 to 630 °C 0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03%
+0.36 °C
10 Ω
Pt(427)
-100 to 260 °C 1.5 °C 3 °C 1 mA 1.5 °C 3 °C
120 Ω
Ni(672)
-80 to 260 °C 0.15 °C 0.3 °C 1 mA 0.15 °C 0.3 °C
50 Ω
Pt(427)
-180 to 200 °C 0.4 °C 0.7 °C 1 mA 0.4 °C 0.7 °C
100 Ω
Pt(427)
-180 to 200 °C 0.2 °C 0.4 °C 1 mA 0.2 °C 0.4 °C
YSI400 15 to 50 °C 0.2 °C 0.4 °C 250 μA 0.2 °C 0.4 °C
1. Sensor misalignment not included.
2. Accuracy: 0.1 °C.
3. The reading accuracy is based on a 4-wire input. For 3-wire RTD measurements, add 1.0 °C (Pt10 and Cu10), 0.6 °C (Pt50 and Cu50), and 0.4 °C (other RTD types) to the technical specifications assuming that all three RTD leads are matched.
4. Output accuracy in Output Mode is based on 0.5 mA to 3 mA (1.00 Ω to 400.00 Ω), 0.05 mA to 0.8 mA (400.0 Ω to 1500.0 Ω), 0.05 mA to 0.4 mA (1500.0 Ω to 4000.0 Ω), and excitation current (0.25 mA in Pt1000 range).
5. Temperature coefficient: ± 0.05 °C /°C for measurement, ± 0.05 °C /°C (28 °C) for source output.
6. Supports pulsed transmitters and PLCs with a pulse time of only 5 ms.

Model: Fluke 712C RTD Calibrator

FLK-712C

Included:

  • Magnetic Hangers
  • batteries
  • instruction manual
  • Traceable calibration certificates
  • Test Leads

F712C technical parameters [please login to download and view].

F712C Quick Reference Guide [please login to download and view]

 